MIB Viewer

fclAsynCfgX3UserP05OutputFlowCtrl

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.20.5.10.15.15
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object indicates the flow control type from the equipment to the terminal. The authorized values are 'none' (no use of XON and XOFF), 'xonXoffInTransfer' (use of XON and XOFF in data transfer), 'xonXoff' (use of XON and XOFF in data transfer and command), 'rtsCtsInTransfer' (use of CTS and RTS signals in transfer). The default value is 'none'.
INTEGER { val0-none(1), val1-xonXoffInTransfer(2), val2-xonXoff(3), val8-rtsCtsInTransfer(9) }