MIB Viewer

fclX25CfaSigInPacketCauseField

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.20.50.1.30.1.21
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object describes which operation the equipment makes on the cause field of reset, clear, and restart request and indication incoming packets. The authorized values are : noModify : no operation, setToZero : the cause field is set to 'DTE originated'. setToZeroIfLowerThan128 : the cause field is set to 'DTE originated' only if the bit 8 is 0 (i.e. if the bits 7 to 1 are those included by the remote DTE). modify : if the cause field is 'Invalid facility request' or 'Local procedure error' then it is changed to 'Network congestion' else no operation. The default value is 'noModify'.
INTEGER { noModify(1), setToZero(2), setToZeroIfLowerThan128(3), modify(4) }