MIB Viewer

fcvLvpFltFilteringFilterId

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.30.10.10.3.1.2
Access
read-only
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object identifies one filter used by this local virtual port. This filter must exist in fcvFltFilterTable. When several filters are simultaneously used on the same virtual port, the equipment analyses them in the incremental order of this filter identifier. So the numbering order must be done with a particular attention. Important : , the value 200 designates a special filter grouping all the frames received by this VP which were not selected by the other filters applied to this VP. This special filter is the last analysed filter for this VP. This filtering process concerns all the traffic received on one of the IP, IPX or CNLP routers or bridge whereas the filtering described in fciFlowTable is made only at the IP level. This is a decimal integer in the range 0 to 200.
INTEGER (0..200)