MIB Viewer

fcvRvpCompressMultiPacketsTimer

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.30.20.4
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object is the multi-packets timer in milliseconds. When the compression is active, the multi-packets function is specified in order to reduce the number of single packets (i.e., without 'More Data mark' = bit M set to 0) transmitted to the remote peer by grouping several packets in an only one compressed output packet. The value 0 disables this function (i.e., each single packet is individually compressed and sent). So to enable this function this timer must be different from 0 on both the local equipment and the remote peer (even when the compression direction is set to 'subscriberToNetwork' or 'subscriberToNetwork'). This timer starts when the equipment begins to fill a new compressed output packet and it is normally stopped when this packet is sent. When this timer runs out the equipment sends this compressed packet even if it is not full. This is a decimal integer in the range 0 to 1500 by step of 100. The default value is '0'.
INTEGER (0..1500)