MIB Viewer

foreSonetVTLoopbackMode

OBJECT-TYPE
1.3.6.1.4.1.326.2.2.1.1.14.5.1.1.1
Access
read-write
Status
current
Sub-identifiers
0
This variable represents the current loopback status of the sonet interface. The possible values are: sonetVTNoLoop(1): interface is not in a loopback state. sonetVTLineLoop(2): data on the receive path is looped back on to the transmit path. sonetVTDiagLoop(3): data to be transmitted on the transmit path is looped back on to the receive path. sonetVTOtherLoop(4): the loopback mode is not defined here.
INTEGER { sonetVTNoLoop(1), sonetVTLineLoop(2), sonetVTDiagLoop(3), sonetVTOtherLoop(4) }