MIB Viewer

friPCfgSubscriberNumber

OBJECT-TYPE
1.3.6.1.4.1.449.2.1.2.1.1.31.1.28
Access
read-write
Status
mandatory
Sub-identifiers
0
All stations on this port use this value for their calling address information element. The valid format of this entry is: xx...xx000101 or xx...xx000103 Where: xx...xx00 represents the address of the station in IA5/ASCII coded hex terminated with a NUL character suffix. For example, an address of 123 would be represented by the string 31323300. 0101 is the suffix used to specify E.164 Number Plan 0103 is the suffix used to specify X.121 Number Plan To send a call without the Subscriber Number IE, set the address string to NUL only.
OCTET STRING (SIZE(3..19))