MIB Viewer

hpiWatchdogTimerAction

OBJECT-TYPE
1.3.6.1.4.1.231.2.60.6.4.10.2.1.4
Access
read-write
Status
mandatory
Sub-identifiers
0
Indicates what action will be taken when the Watchdog times out. Setting this object will NOT take effect on the Watchdog until the object SaHpiWatchdogRunning is set to true(1). Note: Enumerated values are increased by one value compared to SAI-HPI-B spec.
INTEGER { undefined (0), noAction (1), reset (2), powerDown (3), powerCycle (4) }