MIB Viewer

j2LineStatus

OBJECT-TYPE
1.3.6.1.4.1.326.2.2.1.1.6.1.1.1.7
Access
read-only
Status
current
Sub-identifiers
0
This variable indicates the Line Status of the interface. The variable contains loopback state information and failure state information. It is a bit map represented as a sum. The j2NoAlarm should be set if and only if no other flag is set. The various bit positions are: 1 j2NoAlarm 2 j2RxLOF Receive Loss of Frame 4 j2RxLOC Receive Loss of Clock (Not used anymore) 8 j2RxAIS Receive Alarm Indication Signal 16 j2TxLOC Transmit Loss of Clock (Not used anymore) 32 j2RxRAIS Receive Remote Alarm Indication Signal 64 j2RxLOS Receive Loss of Signal 128 j2TxRAIS Transmit Yellow ( Remote Alarm Indication Signal) 256 j2Other any line status not defined here 32768 j2RxLCD Receiving LCD failure indication.
INTEGER (1..65534)