MIB Viewer

m828HubRiFTolState

OBJECT-TYPE
1.3.6.1.4.1.260.1.1.1.2.1.5
Access
read-write
Status
mandatory
Sub-identifiers
0
This parameter controls the Ring In (RI) fault tolerance behavior. The default value for this parameter is the same setting as is present for m828HubRiFTolSw. SETTING this parameter overrides the value derived from m828HubRiFTolSw. Off(1) means that phantom currentis not used on the corresponding RI interface as a condition for main ring link insertion. On (2) means that phantom current is used on the corresponding RI interface as a condition for main ring link insertion. The preffered setting for this parameter is on (2).
INTEGER { off(1), on(2) }