MIB Viewer

mfrapCfgEditConnStatus

OBJECT-TYPE
1.3.6.1.4.1.485.8.2.10.2.5
Access
read-only
Status
mandatory
Source
MFRAP-MIB
Sub-identifiers
0
Displays the status of the connections in the edit buffer. This object should be read before setting the mfrapCfgConnUpdateCmd. Incorrect-dte-bandwidth is returned if there are not enough DS0's starting with the mfrapCfgDteConnStartDs0 to accommodate the mfrapCfgDteConnDs0Required. Incomplete-entry is returned if the source port, source ds0 and/or connection type has not been set for a connection (and at least one of them has been set for that connection). Inconsistent-edit-buffer is returned if there is an internal inconsistency in the edit buffer; in this case, an mfrapCfgEditConnCopyCurrtoEdit or mfrapCfgEditClearEdit set should be performed before proceeding. Bad-connection-type is returned if the connection type is not consistent with the source and destination ports.
INTEGER { connections-valid (1), invalid-dte-bandwidth (2), ds0s-not-ascending (4), incomplete-entry (5), inconsistent-edit-buff (6), bad-connection-type (7), no-current-connections (99) }