MIB Viewer

mfrapStatusDandiStatus

OBJECT-TYPE
1.3.6.1.4.1.485.8.4.15.5
Access
read-only
Status
mandatory
Source
MFRAP-MIB
Sub-identifiers
0
Status of the signal received from the Drop & Insert port. (1) In Sync - unit has detected a properly framed T1 signal and is not experiencing any error conditions. (2) In Sync with Errors - unit has detected a properly framed T1 signal but is experiencing some error conditions. Refer to T1 current performance results for details. (3) Signal Detected without Frame Sync - while a signal is present from the Drop & Insert port, it does not contain the framing pattern defined for this unit. This could be either incorrectly configured T1 Frame type or the presence of an alarm condition on the network. (4) No Carrier - there is no signal detected from the WAN. (5) Not Applicable.
INTEGER { t1-frame-sync-okay (1), t1-frame-sync-with-errors (2), signal-present-without-frame-sync (3), signal-not-present (4), not-applicable (5) }