MIB Viewer

mlinkLostFrameTimer

OBJECT-TYPE
1.3.6.1.4.1.72.14.6.1.1.4
Access
read-write
Status
mandatory
Sub-identifiers
0
This is the Lost Frame Timer. It starts when an out of sequence frame is received, and is not reset until the next expected frame is received. If it expires then the frames between the last received, and the current out-of-sequence frame, are considered to be lost. This timer is in millisecs, but the granularity of the operating value is 50ms, so the value set, is rounded up to the nearest 50ms.
INTEGER ( 50..5000 )