MIB Viewer

mscAtmIfLrcFrameErrors

OBJECT-TYPE
1.3.6.1.4.1.562.36.2.1.114.150.1.34
Access
read-only
Status
mandatory
Sub-identifiers
0
This attribute counts egress LRC frame errors on frames received across the bus. The likely cause of this is a hardware fault on either the sending or receiving card. The counter is reset to zero when the component is created, or when any critical attribute of the component is changed. The counter wraps to zero when it exceeds its maximum value of (2**64)-1. The VPI and VCI of the last connection which exhibited LRC errors are indicated in the attribute lastLrcFrameErrorConnection.
Counter32