MIB Viewer

mscIpiFrLcnDcType

OBJECT-TYPE
1.3.6.1.4.1.562.36.2.1.50.4.2.10.1.6
Access
read-only
Status
mandatory
Sub-identifiers
0
This attribute specifies the type of Vc call: permanentMaster, permanentSlave, If the value is set to permanentMaster, then a permanent connection will be established between 2 ends. The remote end must be defined as a permanentSlave, permanentBackupSlave or permanentSlaveWithBackup. The connection cannot be established if the remote end is defined as anything else. The end defined as permanentMaster always initiates the calls. It will attempt to call once per minute. If the value is set to permanentSlave then a permanent connection will be established between 2 ends. The remote end must be defined as a permanentMaster. The connection cannot be established if the remote end is defined as anything else. The permanentSlave end will attempt to call once per minute.
INTEGER { permanentMaster(1), permanentSlave(2) }