MIB Viewer

mscLpE3RxRaiAlarm

OBJECT-TYPE
1.3.6.1.4.1.562.36.2.1.12.6.16.1.4
Access
read-only
Status
mandatory
Sub-identifiers
0
This attribute displays whether a Remote Alarm Indication (RAI) alarm state has been entered. A RAI alarm state is entered when far- end SEF/AIS defects (or Far-End Receive Failure (FERF) defects in G.832 E3 Framing mode) have been observed and accumulated for a period of 2.5 seconds +/- 0.5 seconds on the E3 incoming line. If the RAI defects are intermittently occurring, the RAI defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The E3 component goes into an operational state of disabled until the RAI alarm condition is cleared. The condition is cleared when the far-end defect indicator has not been detected for 10 seconds +/- 0.5 seconds. The declaration of a RAI Alarm is usually a signal that the far end facility is unable to gain synchronization. The rxRaiAlarm attribute is always set to off when the component has been locked and left offline.
INTEGER { on(0), off(1) }