MIB Viewer

msvmps2StatusInfo

OBJECT-TYPE
1.3.6.1.4.1.9600.1.25.2.2.1.35
Access
read-only
Status
current
Sub-identifiers
0
Note: The use of this method is deprecated in lieu of a more clearly named property (EnabledState) that is inherited from ManagedSystemElement and that has additional enumerated values. Deprecated description: The StatusInfo property indicates whether the Logical Device is in an enabled state (value=3), disabled state (value=4), some other state (value=1), or an unknown state (value=2). If this property does not apply to the LogicalDevice, the value 5 ('Not Applicable') should be used. If a Device is ('Enabled')(value=3), it has been powered up and is configured and operational. The Device might or might not be functionally active, depending on whether its Availability (or AdditionalAvailability) indicates that it is ('Running/Full Power')(value=3) or ('Off line') (value=8). In an enabled but offline mode, a Device might be performing out-of-band requests, such as running Diagnostics. If StatusInfo is ('Disabled') (value=4), a Device can only be 'enabled' or powered off. In a personal computer environment, ('Disabled') means that the driver of the device is not available in the stack. In other environments, a Device can be disabled by removing its configuration file. A disabled device is physically present in a System and consuming resources, but it cannot be communicated with until a driver is loaded, a configuration file is loaded, or some other 'enabling' activity has occurred.
INTEGER { other(1), unknown(2), enabled(3), disabled(4), notApplicable(5) }