MIB Viewer

optDevCmdStatus

OBJECT-TYPE
1.3.6.1.4.1.644.2.4.2.7.1.1.1.9
Access
read-write
Status
current
Sub-identifiers
0
The command status for this link configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Stm1Oc3 Device Cfg Commands used in SET Command (1..99) update-config(1), Change existing Stm1Oc3 Device Configuration Response States used in GET RESPONSE Command (100..199) update-successful (101) Device data has been successfully changed Stm1Oc3 Device Config Error Codes used in GET RESPONSE Command (400..799) err-general-opt-config-error (400) Unknown Device configuration error occurred err-au4Seq-cannot-be-mixed-framing (402) Au4 sequential mode supports only all-E1 or all-T1 Payloads err-invalid-opt-dev-command (403) Unrecognized device command-action err-device-is-protection-module (414) Can't configure Device designated as Protection (odd # slot) err-invalid-multiplex-map (415) Configured multiplexing structure not valid for device type err-invalid-payload-framing (416) Unrecognized payload group type err-invalid-xlink-nest-num (419) X-Link cannot be assigned to selected Nest err-invalid-line-timing (421) Unrecognized clock setting err-ts-alloc-not-applicable (424) Timeslot Alloc can only be configured for STM1 or OC3 cards in Standalone DNX systems err-xlink-pair-not-applicable (427) X-Link assignement can only be changed for STM1X or OC3X cards in DNX88 systems. err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name. err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big
INTEGER { ready-for-command (0), update-config (1), update-successful (101), err-general-opt-config-error (400), err-au4Seq-cannot-be-mixed-framing (402), err-invalid-opt-dev-command (403), err-device-is-protection-module (414), err-invalid-multiplex-map (415), err-invalid-payload-framing (416), err-invalid-xlink-nest-num (419), err-invalid-line-timing (421), err-ts-alloc-not-applicable (424), err-xlink-pair-not-applicable (427), err-data-locked-by-another-user (450), err-snmp-parse-failed (500), err-invalid-snmp-type (501), err-invalid-snmp-var-size (502) }