MIB Viewer

recfSlotModulePortDiagMask

OBJECT-TYPE
1.3.6.1.4.1.16.101.1.2.1.4.1.13
Access
read-write
Status
mandatory
Source
STMIB
Sub-identifiers
0
Parameter Type = Non-intrusive. This mask allows a module to be online or standby even though some items as marked by the mask have failed port startup diagnostics. For all tests, a bit set (1) means the module will not operate if the corresponding hardware is not working. Each byte indicates the diagnostic mask of a port. For T1M and E1M ports: bit 1 (lsb of each byte) Register access bit 2 Loopback bit 3 HDLC bit 4-8 reserved For FSM ports: bit 1 (lsb of each byte) HDLC bit 2-8 reserved For DSM ports: bit 1 (lsb of each byte) HDLC bit 2-8 reserved For RTM ports: bit 1 (lsb of each byte) Loopback bit 2-8 reserved There are no port diagnostics for NCP, SDM, and SGM. The default is to ignore all tests.
OCTET STRING ( SIZE(64) )