MIB Viewer

rptrBasSelfTest1

OBJECT-TYPE
1.3.6.1.4.1.23.2.2.1.1.1.11
Access
read-write
Status
mandatory
Sub-identifiers
0
Setting this variable to selfTest(2) causes the repeater to perform a agent-specific, non- disruptive self-test that has the following characteristics: (1) The nature of the tests is not specified. (2) The test does not change the state of the repeater or management information about the repeater. (3) The test does not inject packets onto any segment. (4) The test does not prevent the relay of any packets. (5) The test does not interfere with management functions. After performing this test the agent will update the repeater health information. If a change in the repeater health has occurred, the agent will send a rptrHealth trap. Setting this variable to noSelfTest(1) has no effect. The agent will always return the value noSelfTest(1) when this variable is read.
INTEGER { noSelfTest(1), selfTest(2) }