MIB Viewer

rptrMonPortRunts

OBJECT-TYPE
1.3.6.1.4.1.23.2.2.2.2.1.10
Access
read-only
Status
mandatory
Sub-identifiers
0
Increment counter by one for each carrier event whose ActivityDuration is greater than ShortEventMaxTime and less than RuntMaxTime. RuntMaxTime is greater than 53.2uS and less than 56.0uS. An event whose length is greater than 7.4uS but less than 8.2uS shall increment either the ShortEvent object or the runts object but not both. A non-collision event greater than 53.2uS but less than 56.0uS may or may not be counted as a runt. A non-collision event greater than or equal to 56.0uS shall not be counted as a Runt. RuntMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Note: Runts do not indicate a problem in the network. The approximate minimum time for counter rollover is 16 hours.
Counter