MIB Viewer

rtxRptrMonitorPortLateCollisions

OBJECT-TYPE
1.3.6.1.4.1.72.14.23.2.2.1.11
Access
read-only
Status
mandatory
Sub-identifiers
0
This counter is incremented by one for each carrier event in which the CIPresent(X) variable has the value SQE (Ref: 9.6.6.2, IEEE 802.3 Std) at any time when the ActivityDuration is greater than the RuntMaxTime. A late collision is counted twice, as both a collision and as a late collision. LateCollisionThreshold has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Note : The approximate minimum time for rollover of this counter is 81 hours.
Counter