MIB Viewer

setMsiEntry

OBJECT-TYPE
1.3.6.1.4.1.601.3.1.1.3.18.4.1
Access
not-accessible
Status
current
Sub-identifiers
30
Input alarm attributes and settings. setMsiChassis Identifies which chassis is being addressed. setMsiSlot Identifies which slot position is being addressed. setMsiPort Identifies which port position is being addressed. setMsiMtieStd Set the input port setting of the MTIE limits to predefined values. setMsiMtie10EL1 Set the input port MTIE 10 seconds error threshold for the first limit setting. setMsiMtie10EL2 Set the input port MTIE 10 seconds error threshold for the second limit setting. setMsiMtie10CL1 Set the input port MTIE 10 seconds clear threshold for the first limit setting. setMsiMtie10CL2 Set the input port MTIE 10 seconds clear threshold for the second limit setting. setMsiMtie100EL1 Set the input port MTIE 100 seconds error threshold for the first limit setting. setMsiMtie100EL2 Set the input port MTIE 100 seconds error threshold for the second limit setting. setMsiMtie100CL1 Set the input port MTIE 100 seconds clear threshold for the first limit setting. setMsiMtie100CL2 Set the input port MTIE 100 seconds clear threshold for the second limit setting. setMsiMtie1000EL1 Set the input port MTIE 1000 seconds error threshold for the first limit setting. setMsiMtie1000EL2 Set the input port MTIE 1000 seconds error threshold for the second limit setting. setMsiMtie1000CL1 Set the input port MTIE 1000 seconds clear threshold for the first limit setting. setMsiMtie1000CL2 Set the input port MTIE 1000 seconds clear threshold for the second limit setting. setMsiMtie10000EL1 Set the input port MTIE 10000 seconds error threshold for the first limit setting. setMsiMtie10000EL2 Set the input port MTIE 10000 seconds error threshold for the second limit setting. setMsiMtie10000CL1 Set the input port MTIE 10000 seconds clear threshold for the first limit setting. setMsiMtie10000CL2 Set the input port MTIE 10000 seconds clear threshold for the second limit setting. setMsiMtie100000EL1 Set the input port MTIE 100000 seconds error threshold for the first limit setting. setMsiMtie100000EL2 Set the input port MTIE 100000 seconds error threshold for the second limit setting. setMsiMtie100000CL1 Set the input port MTIE 100000 seconds clear threshold for the first limit setting. setMsiMtie100000CL2 Set the input port MTIE 100000 seconds clear threshold for the second limit setting. setMsiFreqAErrLmt Set the input port frequency error threshold for clock A. setMsiFreqAClrLmt Set the input port frequency clear threshold for clock A. setMsiFreqATau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A. setMsiFreqBErrLmt Set the input port frequency error threshold for clock B. setMsiFreqBClrLmt Set the input port frequency clear threshold for clock B. setMsiFreqBTau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
SetMsiEntry