MIB Viewer

starCardSPCSwitchoverStart

NOTIFICATION-TYPE
1.3.6.1.4.1.8164.2.19
Status
deprecated
Sub-identifiers
0
An SPC switchover operation has begun. The first varbind identifies the SPC being switched away from; the second varbind identifies the SPC being switched to. Note that since an SPC switchover can cause a momentary loss of communication through the management (SPIO) interface, it is possible that this trap will not be successfully delivered. Probable Cause: This is typically caused by an operator action; it can also represent the system recovering from a software or hardware fault. Action to be Taken: If the SPC switchover was unplanned, the admin logs should be examined for the cause of the switchover. If the cause was a software failure, the system crash logs should be examined. Clear Condition: Verify the SPC switchover completes successfully. Clear Condition Alarm: A starCardSPCSwitchoverComplete is generated when the switchover operation has completed.