MIB Viewer

starMCEAssocDown

NOTIFICATION-TYPE
1.3.6.1.4.1.8164.2.1292
Status
current
Sub-identifiers
0
An MCE Association is down. Problem Cause: SCTP connection between MME and MCE has been brought down - could be for any of the following reasons - i) network connectivity between MME and MCE is broken. ii) MCE has gracefully terminated the SCTP association with MME. iii) MME has gracefully terminated the SCTP association with MCE, typically due to operation intervention that would have effected mme-embms-service. Action to be taken - In case the SCTP association between MME and MCE is abnormally closed, check for network connectivity between MME and MCE. Condition Clear Alarm: In case the association termination was abnormal, A starPeerAssocUp notification will be generated when the MCE association is up