MIB Viewer

unitLedStatus

OBJECT-TYPE
1.3.6.1.4.1.300.110.1.1.14
Access
read-only
Status
mandatory
Sub-identifiers
0
The defined values have the following description Off - The unit is not equipped or is provision in an out of Service state Green - No alarms, status or test conditions exists for the unit Blink Amber - Test conditions are present in the unit Solid Amber - A minor alarm condition persists in the unit or on some interface of the unit, or the unit is powering up. Red - An Alarm condition persists in the unit or on some interface of the unit Blink-Green - reserved Blink-Red - reserved
INTEGER { off (1), green (2), blink-Green (3), blink-Amber (4), solid-Amber (5), red (6), blink-Red (7) }