MIB Viewer

x25ChanDirection

OBJECT-TYPE
1.3.6.1.4.1.72.14.12.6.1.15
Access
read-write
Status
mandatory
Sub-identifiers
0
This parameter will determine the direction call can take on the SVC. When set to originate, a call request packet can be originated on the interface. When set to receive, a call request packet can only be received on the interface. When set to both then a call request packet can be both originated or received on the interface. This parameter must be set to originate or both for the objects x25ChanTimeOfDay x25ChanDataInactivity x25ChanAutoConnectTime to be effective.
INTEGER { receive (1), originate (2), both (3) }