MIB Viewer

x25PvcTxThruputClass

OBJECT-TYPE
1.3.6.1.4.1.495.2.1.6.29.27.1.16
Access
read-write
Status
mandatory
Source
CXX25-MIB
Sub-identifiers
0
The transmit throughput class across the line. At the source side, it defines the throughput class used for packets transmitted to the source interface. At the destination side, it defines the throughput class used for packets received from the destination interface (service access point). This overrides the default settings for the SAP. Options: bps75 (3) bps150 (4) bps300 (5) bps600 (6) bps1200 (7) bps2400 (8) bps4800 (9) bps9600 (10) bps19200 (11) bps48000 (12) bps64000 (13) Default Value: bps9600 (10) Configuration Changed: administrative
ThruputClass