MIB Viewer

x25RouteMask

OBJECT-TYPE
1.3.6.1.4.1.495.2.1.6.29.3
Access
read-write
Status
mandatory
Source
CXX25-MIB
Sub-identifiers
0
Determines the number of digits to use for routing calls. If set to value '0', calls are routed normally, according to the called address specified. A value greater than '0' indicates how many called address digits are used to scan the route table. Any call received with a called address containing less or more digits than specified for this object is refused. Range of Values: 0 - 15 Default Value: 0 Related Objects: x25SapRouteDirection x25RouteTable Configuration Changed: administrative