Determines the amount of system resources which are required by the X.25 layer to avoid congestion. When system resources drop below this threshold, the X.25 layer does the following: - prohibits new virtual circuits from being established on any SAP (service access point) - initiates flow control on all existing virtual circuits receiving data (an RNR is transmitted on each circuit) When global resources rise above this threshold after having dropped below it, the X.25 layer does the following: - it disables flow control on all suspended virtual circuits (transmits a RR on each circuit that that it previously transmitted an RNR on) - permits new virtual circuits to be established The value of this object must not be less than the value of object x25LowerPoolThreshold. Range of Values: 1 - 99 Default Value: 40 (40 percent) Related Objects: x25LowerPoolThreshold x25SapFlowControlTimer Configuration Changed: administrative