ACC-DS3
24 objects
No module-level DESCRIPTION found.
Imported Objects
| ACC-MIB | accBRG DisplayString IfIndex RowStatus SmdsAddress |
| ACC-SYSTEM | accTrapLogSeqNum |
| RFC1155-SMI | Counter OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5.1.1.79 | TableaccDs3InfcTable | not-accessible | mandatory | The DS3 interface table. |
| 1.3.6.1.4.1.5.1.1.79.1 | RowaccDs3InfcEntry | not-accessible | mandatory | An entry in the DS3 interface table. |
| 1.3.6.1.4.1.5.1.1.79.1.1 | ColumnaccDs3InfcServiceState | read-write | mandatory | Indicates DS3 interface service state. Certain attributes require that the service state be in a certain state before they can be altered. |
| 1.3.6.1.4.1.5.1.1.79.1.2 | ColumnaccDs3InfcLoopbackOp | read-write | mandatory | The local loopback mode of a DS3 interface. The entire DS3 line can be set or each individual DS1 line within the DS3 can be set separately. |
| 1.3.6.1.4.1.5.1.1.79.1.3 | ColumnaccDs3InfcLoopbackCO | read-only | mandatory | The loopback state of a DS3 interface when loopback is initiated remotely. A DS3 line can be set, or individual DS1 lines within the DS3 can be set separately. |
| 1.3.6.1.4.1.5.1.1.79.1.4 | ColumnaccDs3InfcLineLength | read-write | mandatory | The approximate line length. The default is short. |
| 1.3.6.1.4.1.5.1.1.79.1.5 | ColumnaccDs3InfcMdlProtocol | read-write | mandatory | The terminal to terminal path maintenance data link protocol of the DS3 interface. |
| 1.3.6.1.4.1.5.1.1.79.1.6 | ColumnaccDs3InfcTxMdlEic | read-write | mandatory | The local MDL equipment identification code for the DS3 interface. Describes the equipment. |
| 1.3.6.1.4.1.5.1.1.79.1.7 | ColumnaccDs3InfcTxMdlLic | read-write | mandatory | The local MDL location identification code for the DS3 interface. Describes specific location of the equipment. |
| 1.3.6.1.4.1.5.1.1.79.1.8 | ColumnaccDs3InfcTxMdlFic | read-write | mandatory | The local MDL frame identification code for the DS3 interface. Identifies where the specific piece of equipment is located in a building |
| 1.3.6.1.4.1.5.1.1.79.1.9 | ColumnaccDs3InfcTxMdlUnit | read-write | mandatory | The local MDL unit identification for the DS3 interface. It identifies where the specific piece of equipment is located within a bay. |
| 1.3.6.1.4.1.5.1.1.79.1.10 | ColumnaccDs3InfcTxMdlFac | read-write | mandatory | The local MDL facility identification code for the DS3 interface. Describes a specific DS3 path. |
| 1.3.6.1.4.1.5.1.1.79.1.11 | ColumnaccDs3InfcTxMdlPort | read-write | mandatory | The local MDL port identification code for the DS3 interface. Describes port on the equipment that will initiate the idle signal. |
| 1.3.6.1.4.1.5.1.1.79.1.12 | ColumnaccDs3InfcTxMdlGen | read-write | mandatory | The local MDL generator number for the DS3 interface. Describes the signal generator that will initiate the test signal. |
| 1.3.6.1.4.1.5.1.1.79.1.13 | ColumnaccDs3InfcRxMdlEic | read-only | mandatory | The remote MDL equipment identification code for the DS3 interface. Describes the equipment. |
| 1.3.6.1.4.1.5.1.1.79.1.14 | ColumnaccDs3InfcRxMdlLic | read-only | mandatory | The remote MDL location identification code for the DS3 interface. Describes specific location of the equipment. |
| 1.3.6.1.4.1.5.1.1.79.1.15 | ColumnaccDs3InfcRxMdlFic | read-only | mandatory | The remote MDL frame identification code for the DS3 interface. Identifies where the specific piece of equipment is located in a building |
| 1.3.6.1.4.1.5.1.1.79.1.16 | ColumnaccDs3InfcRxMdlUnit | read-only | mandatory | The remote MDL unit identification for the DS3 interface. It identifies where the specific piece of equipment is located within a bay. |
| 1.3.6.1.4.1.5.1.1.79.1.17 | ColumnaccDs3InfcRxMdlFac | read-only | mandatory | The remote MDL unit identification for the DS3 interface. It identifies where the specific piece of equipment is located within a bay. |
| 1.3.6.1.4.1.5.1.1.79.1.18 | ColumnaccDs3InfcRxMdlPort | read-only | mandatory | The remote MDL port identification code for the DS3 interface. Describes port on the equipment that will initiate the idle signal. |
| 1.3.6.1.4.1.5.1.1.79.1.19 | ColumnaccDs3InfcRxMdlGen | read-only | mandatory | The remote MDL generator number for the DS3 interface. Describes the signal generator that will initiate the test signal. |
| 1.3.6.1.4.1.5.1.1.79.1.20 | ColumnaccDs3InfcRxMdlPathAges | read-only | mandatory | |
| 1.3.6.1.4.1.5.1.1.79.1.21 | ColumnaccDs3InfcRxMdlIdleAges | read-only | mandatory | |
| 1.3.6.1.4.1.5.1.1.79.1.22 | ColumnaccDs3InfcRxMdlTestAges | read-only | mandatory |