| 1.3.6.1.4.1.5.1.1.5 | NodeaccSlot | |||
| 1.3.6.1.4.1.5.1.1.5.2 | TableaccSlotTable | not-accessible | mandatory | A list of physical port entries. The number of entries is given by the value of accSlotNum. |
| 1.3.6.1.4.1.5.1.1.5.2.1 | RowaccSlotEntry | not-accessible | mandatory | A table entry providing information about a specific physical port. |
| 1.3.6.1.4.1.5.1.1.5.2.1.11 | ColumnaccSlotInPkts | read-only | mandatory | Number of packets received on this physical interface. |
| 1.3.6.1.4.1.5.1.1.5.2.1.17 | ColumnaccSlotOutPkts | read-only | mandatory | Number of packets transmitted on this physical interface. |
| 1.3.6.1.4.1.5.1.1.5.2.1.21 | ColumnaccSlotNumChanges | read-only | mandatory | Number of times that this interface has changed state (either up-to-down or down-to-up). |
| 1.3.6.1.4.1.5.1.1.5.2.1.22 | ColumnaccSlotProtocol | read-write | mandatory | Protocol used on this slot. note that these enumerated values match those in accBrPortProtocol. |
| 1.3.6.1.4.1.5.1.1.5.2.1.23 | ColumnaccSlotClockMode | read-write | mandatory | Clock mode of this port |
| 1.3.6.1.4.1.5.1.1.5.2.1.24 | ColumnaccSlotQueueMode | read-write | mandatory | Queuing mode for this slot Fair queuing provides per-conversation bandwidth allocation, with additional bandwidth allocated to higher priority traffic. Precede… |
| 1.3.6.1.4.1.5.1.1.5.2.1.25 | ColumnaccSlotDialProcedure | read-write | mandatory | Dial Procedure. |
| 1.3.6.1.4.1.5.1.1.5.2.1.26 | ColumnaccSlotResyncMode | read-write | mandatory | Establishes operational mode of the Resync function for crypto gear. When active, a link-down condition intitiates resynchronization, which is manifested by se… |
| 1.3.6.1.4.1.5.1.1.5.2.1.27 | ColumnaccSlotCompressMode | read-write | mandatory | Establishes operational mode of Data Compression. This functionality is appropriate for serial lines. |
| 1.3.6.1.4.1.5.1.1.5.2.1.29 | ColumnaccSlotCompressV42bisP1 | read-only | mandatory | Number of codewords |
| 1.3.6.1.4.1.5.1.1.5.2.1.30 | ColumnaccSlotCompressV42bisP2 | read-only | mandatory | Maximum string size |
| 1.3.6.1.4.1.5.1.1.5.2.1.31 | ColumnaccSlotCompressDcs221P1 | read-write | mandatory | Compression Mode |
| 1.3.6.1.4.1.5.1.1.5.2.1.32 | ColumnaccSlotSevereCongPct | read-write | mandatory | Percent Congested |
| 1.3.6.1.4.1.5.1.1.5.2.1.33 | ColumnaccSlotDialAddress | read-write | mandatory | Dial Address. |
| 1.3.6.1.4.1.5.1.1.5.2.1.34 | ColumnaccSlotCompressRevision | read-write | mandatory | Indicates which data compression algorithm should be used for this physical port. If the confi gured protocol is Frame Relay, X.25 or PPP, the com pression mod… |
| 1.3.6.1.4.1.5.1.1.5.2.1.35 | ColumnaccSlotCompressMaxStreams | read-write | mandatory | The maximum number of independent data streams for this physical port. This object determines the size of the history buffer pool. |
| 1.3.6.1.4.1.5.1.1.5.2.1.36 | ColumnaccSlotCompressMessageLevel | read-write | mandatory | . |
| 1.3.6.1.4.1.5.1.1.5.2.1.37 | ColumnaccSlotIfType | read-write | mandatory | . |
| 1.3.6.1.4.1.5.1.1.5.2.1.38 | ColumnaccSlotE1FrameMode | read-write | mandatory | . |
| 1.3.6.1.4.1.5.1.1.5.2.1.39 | ColumnaccSlotLastChangeY2K | read-only | mandatory | Time when a state change was last detected on this physical port. The seven byte long octet string represents year 2000 compliant date and time, and is laid ou… |
| 1.3.6.1.4.1.5.1.1.5.3 | TableaccCardSlotTable | not-accessible | mandatory | A table providing objects for each installed card in the system chassis slots. |
| 1.3.6.1.4.1.5.1.1.5.3.1 | RowaccCardSlotEntry | not-accessible | mandatory | Contains a summary of objects for a slot entry. |
| 1.3.6.1.4.1.5.1.1.5.3.1.1 | ColumnaccCardSlotNum | read-only | mandatory | An integer that uniquely identifies the card slot within the system chassis. |
| 1.3.6.1.4.1.5.1.1.5.3.1.2 | ColumnaccCardSlotType | read-only | mandatory | An integer value which uniquely identifies the card type. |
| 1.3.6.1.4.1.5.1.1.5.3.1.3 | ColumnaccCardSlotRevNum | read-only | mandatory | A printable ASCII string representing the card rev number. |
| 1.3.6.1.4.1.5.1.1.5.3.1.4 | ColumnaccCardSlotSerNum | read-only | mandatory | A printable ASCII string representing the card serial num. |
| 1.3.6.1.4.1.5.1.1.5.3.1.5 | ColumnaccCardSlotPortCnf | read-only | mandatory | A printable ASCII string representing the interface configuration on this slot. |
| 1.3.6.1.4.1.5.1.1.5.3.1.6 | ColumnaccCardSlotAdminState | read-write | mandatory | An integer value which uniquely identifies the card administration state. |
| 1.3.6.1.4.1.5.1.1.5.3.1.7 | ColumnaccCardSlotOperState | read-write | mandatory | An integer value which uniquely identifies the card operational state. |
| 1.3.6.1.4.1.5.1.1.5.3.1.8 | ColumnaccCardSlotIndex | read-only | mandatory | The ifIndex for this slot. |
| 1.3.6.1.4.1.5.1.1.5.3.1.9 | ColumnaccCardSlotNum11Slot | read-only | mandatory | An integer that uniquely identifies the card slot within the 11-Slot system chassis. This can be used as an alternate index into accCardSlotTable. |
| 1.3.6.1.4.1.5.1.1.5.4 | TableaccCardInterfaceTable | not-accessible | mandatory | A table providing interface information for each interface on the system indicating how they relate to system slots. |
| 1.3.6.1.4.1.5.1.1.5.4.1 | RowaccCardInterfaceEntry | not-accessible | mandatory | Contains a summary of objects for an interface entry. |
| 1.3.6.1.4.1.5.1.1.5.4.1.1 | ColumnaccCardInterfaceNum | read-only | mandatory | An integer that uniquely identifies the interface within the slot card. |
| 1.3.6.1.4.1.5.1.1.5.4.1.2 | ColumnaccCardInterfaceType | read-only | mandatory | The interface type - need to define enumerations here !! |
| 1.3.6.1.4.1.5.1.1.5.4.1.3 | ColumnaccCardInterfaceSlotNum | read-only | mandatory | The slot number that this interface resides on - corresponds to accCardSlotNum. |
| 1.3.6.1.4.1.5.1.1.5.4.1.4 | ColumnaccCardInterfaceIndex | read-only | mandatory | The ifIndex for this interface. |
| 1.3.6.1.4.1.5.1.1.5.5 | TableaccCardCircuitTable | not-accessible | mandatory | A table providing information for each circuit installed in the system chassis, indicating how they relate to slots and interfaces. |
| 1.3.6.1.4.1.5.1.1.5.5.1 | RowaccCardCircuitEntry | not-accessible | mandatory | Contains a summary of objects for a circuit entry. |
| 1.3.6.1.4.1.5.1.1.5.5.1.1 | ColumnaccCardCircuitNum | read-only | mandatory | An integer that uniquely identifies the circuit within the interface. |
| 1.3.6.1.4.1.5.1.1.5.5.1.2 | ColumnaccCardCircuitSlotNum | read-only | mandatory | The slot number that this circuit resides on - corresponds to accCardSlotNum. |
| 1.3.6.1.4.1.5.1.1.5.5.1.3 | ColumnaccCardCircuitInterfaceNum | read-only | mandatory | The interface number that this circuit resides on - corresponds to accCardInterfaceNum. |
| 1.3.6.1.4.1.5.1.1.5.5.1.4 | ColumnaccCardCircuitIndex | read-only | mandatory | The ifIndex for this circuit. |
| 1.3.6.1.4.1.5.1.1.5.6 | NodeaccCardSlotTraps | |||
| 1.3.6.1.4.1.5.1.1.5.6.1 | ScalaraccCardSlotTrapMsg | read-only | mandatory | Enterprise Trap Message for CardSlot |
| 1.3.6.1.4.1.5.1.1.5.6.1 | NodeaccRmReqResetTrap | This trap is generated when a particular command which is a part of feature that is set to ON from OFF using the EME feature indicating that a reload can actua… | ||
| 1.3.6.1.4.1.5.1.1.5.6.2 | NodeaccRmFeatureTrap | This trap is generated when a particular command which is a part of feature that is set to OFF using the EME feature. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT… | ||
| 1.3.6.1.4.1.5.1.1.5.6.3 | NodeaccRmCardRemovedTrap | This indicates that a Card has been removed and tried to acticvate or deactivate the respective card SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL… | ||
| 1.3.6.1.4.1.5.1.1.5.6.4 | NodeaccRmActvComplTrap | When the command to activate a card is issued. This trap indicates the activation was sucessfully done SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITION… | ||
| 1.3.6.1.4.1.5.1.1.5.6.5 | NodeaccRmActvStartTrap | When the command to activate card is issued. This trap indicates the activation has started SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VAR… | ||
| 1.3.6.1.4.1.5.1.1.5.6.6 | NodeaccRmActvFailTrap | When the command (set slot state) to activate card is issued. This trap is generated in case of a failure or Mismatch of the slot. SEVERITY-DEFAULT: Critical E… | ||
| 1.3.6.1.4.1.5.1.1.5.6.7 | NodeaccRmDeActvStartTrap | When the command (set slot state) to deactivate card is issued. This trap indicates the deactivation has started. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT:… | ||
| 1.3.6.1.4.1.5.1.1.5.6.8 | NodeaccRmDeActvComplTrap | When the command (set slot state) to deactivate a card is issued. This trap indicates the deactivation was sucessfully done SEVERITY-DEFAULT: Critical EVENTTYP… | ||
| 1.3.6.1.4.1.5.1.1.5.6.9 | NodeaccRmCardRemvdTrap | This indicates that a Card has been removed after deactivating the slot using the set slot state command SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITI… | ||
| 1.3.6.1.4.1.5.1.1.5.6.10 | NodeaccRmInvStateTrap | If the card is BUSY and cannot be deactivated this trap is generated SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeq… | ||
| 1.3.6.1.4.1.5.1.1.5.6.11 | NodeaccRmFaultHndlTrap | Fault Hndl, Invalid State SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15 | ||
| 1.3.6.1.4.1.5.1.1.5.6.12 | NodeaccRmFaultIndTrap | Fault Indication (reason), Slot SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAU… | ||
| 1.3.6.1.4.1.5.1.1.5.6.13 | NodeaccRmDataCallTrap | This is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap c… | ||
| 1.3.6.1.4.1.5.1.1.5.6.14 | NodeaccRmDataEnableTrap | This is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the initiate data call request has come, then th… | ||
| 1.3.6.1.4.1.5.1.1.5.6.15 | NodeaccRmDataCallAccptTrap | This is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap c… | ||
| 1.3.6.1.4.1.5.1.1.5.6.16 | NodeaccRmDataSwitchTrap | This is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap c… | ||
| 1.3.6.1.4.1.5.1.1.5.6.17 | NodeaccRmFrmWareLoadAbortTrap | This is a trap which is because of a alloc failure due to memory shortage. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLo… | ||
| 1.3.6.1.4.1.5.1.1.5.6.18 | NodeaccRmBfrAllocTrap | This is a trap which is because of a alloc failure due to memory shortage. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLo… | ||
| 1.3.6.1.4.1.5.1.1.5.6.19 | NodeaccRmLoadAbortTrap | If the file is corrupted the loading is aborted and is indicated by this trap. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTr… | ||
| 1.3.6.1.4.1.5.1.1.5.6.20 | NodeaccRmFrmwrCompatiblTrap | If the extension is not supported by the version of the apl file then this trap is sent. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLE… | ||
| 1.3.6.1.4.1.5.1.1.5.6.21 | NodeaccRmLoadTrap5 | This is basically a revision mismatch. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-… | ||
| 1.3.6.1.4.1.5.1.1.5.6.22 | NodeaccRmSwUpGradeMsgTrap | THIS ROUTER WILL NOT OPERATE WITH FULL FUNCTIONALITY UNTIL A VALID KEY HAS BEEN ENTERED SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIAB… | ||
| 1.3.6.1.4.1.5.1.1.5.6.23 | NodeaccRmInSuffRAMTrap | This is a memory related trap indicating that sufficient RAM is not on the borad, so that the admin can take the appropriate action of increasing the memory or… | ||
| 1.3.6.1.4.1.5.1.1.5.6.24 | NodeaccRmPwrSplyMalfnTrap | This is a TIGRIS Power supply trap indicating that the one of the Power Supply is not OK and should be replaced. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: … | ||
| 1.3.6.1.4.1.5.1.1.5.6.25 | NodeaccRmPwrSplyStatTrap | When one of the DUAL TIGRIS Power supply is removed or inserted this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITION… | ||
| 1.3.6.1.4.1.5.1.1.5.6.26 | NodeaccRmFanStatTrap | If the fan in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEX… | ||
| 1.3.6.1.4.1.5.1.1.5.6.27 | NodeaccRmDcStatTrap | If the AC componemt in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDIT… | ||
| 1.3.6.1.4.1.5.1.1.5.6.28 | NodeaccRmAcStatTrap | If the DC componemt in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARI… | ||
| 1.3.6.1.4.1.5.1.1.5.6.29 | NodeaccRmPwr1PresTrap | If the power supply is removed or installed this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: {… | ||
| 1.3.6.1.4.1.5.1.1.5.6.30 | NodeaccRmPwrFan1Trap | If the Tigris power supply fan fails or recovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIAB… | ||
| 1.3.6.1.4.1.5.1.1.5.6.31 | NodeaccRmPwrDc1Trap | If the Tigris power supply DC Component fails or recovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TE… | ||
| 1.3.6.1.4.1.5.1.1.5.6.32 | NodeaccRmPwrAc1Trap | If the Tigris power supply AC Component fails or recovered this trap is generated. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: {… | ||
| 1.3.6.1.4.1.5.1.1.5.6.33 | NodeaccRmEalm2Trap | Trap indicating the external 2nd alarm status of the fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCard… | ||
| 1.3.6.1.4.1.5.1.1.5.6.34 | NodeaccRmEalm1Trap | Trap indicating the external 1st alarm status of the fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCard… | ||
| 1.3.6.1.4.1.5.1.1.5.6.35 | NodeaccRmChasFanPresTrap | Trap indicating the status of the chasis fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg … | ||
| 1.3.6.1.4.1.5.1.1.5.6.36 | NodeaccRmChasFanIndTrap | Trap indicating the status of the chasis fan whether it failed or recovered. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VAR… | ||
| 1.3.6.1.4.1.5.1.1.5.6.37 | NodeaccRmLowMemTrap | This indicates very clearly that the Memory is very low and the admin has to do some dagnostics and take a quick action on the various memory critical issues f… | ||
| 1.3.6.1.4.1.5.1.1.5.6.38 | NodeaccRmLanDiagsTrap | When the diagnostics on the particular LAN slot fails this trap is generated. Indicating that there is some problem with that interface. SEVERITY-DEFAULT: Crit… | ||
| 1.3.6.1.4.1.5.1.1.5.6.39 | NodeaccRmWanDiagsTrap | When the diagnostics on the particular WAN slot fails this trap is generated. Indicating that there is some problem with that interface. SEVERITY-DEFAULT: Crit… | ||
| 1.3.6.1.4.1.5.1.1.5.6.40 | NodeaccRmCardDiagsTrap | When the diagnostics on the particular CARD slot fails this trap is generated. Indicating that there is some problem with that CARD. SEVERITY-DEFAULT: Critical… | ||
| 1.3.6.1.4.1.5.1.1.5.6.41 | NodeaccRmResetTrap | This trap is to prompt the admin to reset the router as he would have changed some settings and they will be effective only after a reset for example change/de… | ||
| 1.3.6.1.4.1.5.1.1.5.6.42 | NodeaccRmIdbTrap | SEVERITY-DEFAULT: Indeterminate EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0 | ||
| 1.3.6.1.4.1.5.1.1.5.6.43 | NodeaccRmLdngElemManTrap | Browser loading Element Manager at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE… | ||
| 1.3.6.1.4.1.5.1.1.5.6.44 | NodeaccRmInterFileJavaManTrap | Intermediate file sent to Java Manager %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PC… | ||
| 1.3.6.1.4.1.5.1.1.5.6.45 | NodeaccRmBrowLdngSetupWizTrap | Browser loading Java Setup Wizard at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAU… | ||
| 1.3.6.1.4.1.5.1.1.5.6.46 | NodeaccRmConfWizLddTrap | Configuration Wizard is being loaded by the browser at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCard… | ||
| 1.3.6.1.4.1.5.1.1.5.6.47 | NodeaccRmPriConfScrTrap | Primary config script sent to Configuration Wizard at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardS… | ||
| 1.3.6.1.4.1.5.1.1.5.6.48 | NodeaccRmInstAccAppLddTrap | Instant Access applet is being loaded by the browser at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCar… |