MIB Viewer

ACC-SLOT

96 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5.1.1.5NodeaccSlot
1.3.6.1.4.1.5.1.1.5.2TableaccSlotTablenot-accessiblemandatoryA list of physical port entries. The number of entries is given by the value of accSlotNum.
1.3.6.1.4.1.5.1.1.5.2.1RowaccSlotEntrynot-accessiblemandatoryA table entry providing information about a specific physical port.
1.3.6.1.4.1.5.1.1.5.2.1.11ColumnaccSlotInPktsread-onlymandatoryNumber of packets received on this physical interface.
1.3.6.1.4.1.5.1.1.5.2.1.17ColumnaccSlotOutPktsread-onlymandatoryNumber of packets transmitted on this physical interface.
1.3.6.1.4.1.5.1.1.5.2.1.21ColumnaccSlotNumChangesread-onlymandatoryNumber of times that this interface has changed state (either up-to-down or down-to-up).
1.3.6.1.4.1.5.1.1.5.2.1.22ColumnaccSlotProtocolread-writemandatoryProtocol used on this slot. note that these enumerated values match those in accBrPortProtocol.
1.3.6.1.4.1.5.1.1.5.2.1.23ColumnaccSlotClockModeread-writemandatoryClock mode of this port
1.3.6.1.4.1.5.1.1.5.2.1.24ColumnaccSlotQueueModeread-writemandatoryQueuing mode for this slot Fair queuing provides per-conversation bandwidth allocation, with additional bandwidth allocated to higher priority traffic. Precede…
1.3.6.1.4.1.5.1.1.5.2.1.25ColumnaccSlotDialProcedureread-writemandatoryDial Procedure.
1.3.6.1.4.1.5.1.1.5.2.1.26ColumnaccSlotResyncModeread-writemandatoryEstablishes operational mode of the Resync function for crypto gear. When active, a link-down condition intitiates resynchronization, which is manifested by se…
1.3.6.1.4.1.5.1.1.5.2.1.27ColumnaccSlotCompressModeread-writemandatoryEstablishes operational mode of Data Compression. This functionality is appropriate for serial lines.
1.3.6.1.4.1.5.1.1.5.2.1.29ColumnaccSlotCompressV42bisP1read-onlymandatoryNumber of codewords
1.3.6.1.4.1.5.1.1.5.2.1.30ColumnaccSlotCompressV42bisP2read-onlymandatoryMaximum string size
1.3.6.1.4.1.5.1.1.5.2.1.31ColumnaccSlotCompressDcs221P1read-writemandatoryCompression Mode
1.3.6.1.4.1.5.1.1.5.2.1.32ColumnaccSlotSevereCongPctread-writemandatoryPercent Congested
1.3.6.1.4.1.5.1.1.5.2.1.33ColumnaccSlotDialAddressread-writemandatoryDial Address.
1.3.6.1.4.1.5.1.1.5.2.1.34ColumnaccSlotCompressRevisionread-writemandatoryIndicates which data compression algorithm should be used for this physical port. If the confi gured protocol is Frame Relay, X.25 or PPP, the com pression mod…
1.3.6.1.4.1.5.1.1.5.2.1.35ColumnaccSlotCompressMaxStreamsread-writemandatoryThe maximum number of independent data streams for this physical port. This object determines the size of the history buffer pool.
1.3.6.1.4.1.5.1.1.5.2.1.36ColumnaccSlotCompressMessageLevelread-writemandatory.
1.3.6.1.4.1.5.1.1.5.2.1.37ColumnaccSlotIfTyperead-writemandatory.
1.3.6.1.4.1.5.1.1.5.2.1.38ColumnaccSlotE1FrameModeread-writemandatory.
1.3.6.1.4.1.5.1.1.5.2.1.39ColumnaccSlotLastChangeY2Kread-onlymandatoryTime when a state change was last detected on this physical port. The seven byte long octet string represents year 2000 compliant date and time, and is laid ou…
1.3.6.1.4.1.5.1.1.5.3TableaccCardSlotTablenot-accessiblemandatoryA table providing objects for each installed card in the system chassis slots.
1.3.6.1.4.1.5.1.1.5.3.1RowaccCardSlotEntrynot-accessiblemandatoryContains a summary of objects for a slot entry.
1.3.6.1.4.1.5.1.1.5.3.1.1ColumnaccCardSlotNumread-onlymandatoryAn integer that uniquely identifies the card slot within the system chassis.
1.3.6.1.4.1.5.1.1.5.3.1.2ColumnaccCardSlotTyperead-onlymandatoryAn integer value which uniquely identifies the card type.
1.3.6.1.4.1.5.1.1.5.3.1.3ColumnaccCardSlotRevNumread-onlymandatoryA printable ASCII string representing the card rev number.
1.3.6.1.4.1.5.1.1.5.3.1.4ColumnaccCardSlotSerNumread-onlymandatoryA printable ASCII string representing the card serial num.
1.3.6.1.4.1.5.1.1.5.3.1.5ColumnaccCardSlotPortCnfread-onlymandatoryA printable ASCII string representing the interface configuration on this slot.
1.3.6.1.4.1.5.1.1.5.3.1.6ColumnaccCardSlotAdminStateread-writemandatoryAn integer value which uniquely identifies the card administration state.
1.3.6.1.4.1.5.1.1.5.3.1.7ColumnaccCardSlotOperStateread-writemandatoryAn integer value which uniquely identifies the card operational state.
1.3.6.1.4.1.5.1.1.5.3.1.8ColumnaccCardSlotIndexread-onlymandatoryThe ifIndex for this slot.
1.3.6.1.4.1.5.1.1.5.3.1.9ColumnaccCardSlotNum11Slotread-onlymandatoryAn integer that uniquely identifies the card slot within the 11-Slot system chassis. This can be used as an alternate index into accCardSlotTable.
1.3.6.1.4.1.5.1.1.5.4TableaccCardInterfaceTablenot-accessiblemandatoryA table providing interface information for each interface on the system indicating how they relate to system slots.
1.3.6.1.4.1.5.1.1.5.4.1RowaccCardInterfaceEntrynot-accessiblemandatoryContains a summary of objects for an interface entry.
1.3.6.1.4.1.5.1.1.5.4.1.1ColumnaccCardInterfaceNumread-onlymandatoryAn integer that uniquely identifies the interface within the slot card.
1.3.6.1.4.1.5.1.1.5.4.1.2ColumnaccCardInterfaceTyperead-onlymandatoryThe interface type - need to define enumerations here !!
1.3.6.1.4.1.5.1.1.5.4.1.3ColumnaccCardInterfaceSlotNumread-onlymandatoryThe slot number that this interface resides on - corresponds to accCardSlotNum.
1.3.6.1.4.1.5.1.1.5.4.1.4ColumnaccCardInterfaceIndexread-onlymandatoryThe ifIndex for this interface.
1.3.6.1.4.1.5.1.1.5.5TableaccCardCircuitTablenot-accessiblemandatoryA table providing information for each circuit installed in the system chassis, indicating how they relate to slots and interfaces.
1.3.6.1.4.1.5.1.1.5.5.1RowaccCardCircuitEntrynot-accessiblemandatoryContains a summary of objects for a circuit entry.
1.3.6.1.4.1.5.1.1.5.5.1.1ColumnaccCardCircuitNumread-onlymandatoryAn integer that uniquely identifies the circuit within the interface.
1.3.6.1.4.1.5.1.1.5.5.1.2ColumnaccCardCircuitSlotNumread-onlymandatoryThe slot number that this circuit resides on - corresponds to accCardSlotNum.
1.3.6.1.4.1.5.1.1.5.5.1.3ColumnaccCardCircuitInterfaceNumread-onlymandatoryThe interface number that this circuit resides on - corresponds to accCardInterfaceNum.
1.3.6.1.4.1.5.1.1.5.5.1.4ColumnaccCardCircuitIndexread-onlymandatoryThe ifIndex for this circuit.
1.3.6.1.4.1.5.1.1.5.6NodeaccCardSlotTraps
1.3.6.1.4.1.5.1.1.5.6.1ScalaraccCardSlotTrapMsgread-onlymandatoryEnterprise Trap Message for CardSlot
1.3.6.1.4.1.5.1.1.5.6.1NodeaccRmReqResetTrapThis trap is generated when a particular command which is a part of feature that is set to ON from OFF using the EME feature indicating that a reload can actua…
1.3.6.1.4.1.5.1.1.5.6.2NodeaccRmFeatureTrapThis trap is generated when a particular command which is a part of feature that is set to OFF using the EME feature. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT…
1.3.6.1.4.1.5.1.1.5.6.3NodeaccRmCardRemovedTrapThis indicates that a Card has been removed and tried to acticvate or deactivate the respective card SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL…
1.3.6.1.4.1.5.1.1.5.6.4NodeaccRmActvComplTrapWhen the command to activate a card is issued. This trap indicates the activation was sucessfully done SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITION…
1.3.6.1.4.1.5.1.1.5.6.5NodeaccRmActvStartTrapWhen the command to activate card is issued. This trap indicates the activation has started SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VAR…
1.3.6.1.4.1.5.1.1.5.6.6NodeaccRmActvFailTrapWhen the command (set slot state) to activate card is issued. This trap is generated in case of a failure or Mismatch of the slot. SEVERITY-DEFAULT: Critical E…
1.3.6.1.4.1.5.1.1.5.6.7NodeaccRmDeActvStartTrapWhen the command (set slot state) to deactivate card is issued. This trap indicates the deactivation has started. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT:…
1.3.6.1.4.1.5.1.1.5.6.8NodeaccRmDeActvComplTrapWhen the command (set slot state) to deactivate a card is issued. This trap indicates the deactivation was sucessfully done SEVERITY-DEFAULT: Critical EVENTTYP…
1.3.6.1.4.1.5.1.1.5.6.9NodeaccRmCardRemvdTrapThis indicates that a Card has been removed after deactivating the slot using the set slot state command SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITI…
1.3.6.1.4.1.5.1.1.5.6.10NodeaccRmInvStateTrapIf the card is BUSY and cannot be deactivated this trap is generated SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeq…
1.3.6.1.4.1.5.1.1.5.6.11NodeaccRmFaultHndlTrapFault Hndl, Invalid State SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15
1.3.6.1.4.1.5.1.1.5.6.12NodeaccRmFaultIndTrapFault Indication (reason), Slot SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAU…
1.3.6.1.4.1.5.1.1.5.6.13NodeaccRmDataCallTrapThis is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap c…
1.3.6.1.4.1.5.1.1.5.6.14NodeaccRmDataEnableTrapThis is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the initiate data call request has come, then th…
1.3.6.1.4.1.5.1.1.5.6.15NodeaccRmDataCallAccptTrapThis is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap c…
1.3.6.1.4.1.5.1.1.5.6.16NodeaccRmDataSwitchTrapThis is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap c…
1.3.6.1.4.1.5.1.1.5.6.17NodeaccRmFrmWareLoadAbortTrapThis is a trap which is because of a alloc failure due to memory shortage. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLo…
1.3.6.1.4.1.5.1.1.5.6.18NodeaccRmBfrAllocTrapThis is a trap which is because of a alloc failure due to memory shortage. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLo…
1.3.6.1.4.1.5.1.1.5.6.19NodeaccRmLoadAbortTrapIf the file is corrupted the loading is aborted and is indicated by this trap. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTr…
1.3.6.1.4.1.5.1.1.5.6.20NodeaccRmFrmwrCompatiblTrapIf the extension is not supported by the version of the apl file then this trap is sent. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLE…
1.3.6.1.4.1.5.1.1.5.6.21NodeaccRmLoadTrap5This is basically a revision mismatch. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-…
1.3.6.1.4.1.5.1.1.5.6.22NodeaccRmSwUpGradeMsgTrapTHIS ROUTER WILL NOT OPERATE WITH FULL FUNCTIONALITY UNTIL A VALID KEY HAS BEEN ENTERED SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIAB…
1.3.6.1.4.1.5.1.1.5.6.23NodeaccRmInSuffRAMTrapThis is a memory related trap indicating that sufficient RAM is not on the borad, so that the admin can take the appropriate action of increasing the memory or…
1.3.6.1.4.1.5.1.1.5.6.24NodeaccRmPwrSplyMalfnTrapThis is a TIGRIS Power supply trap indicating that the one of the Power Supply is not OK and should be replaced. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: …
1.3.6.1.4.1.5.1.1.5.6.25NodeaccRmPwrSplyStatTrapWhen one of the DUAL TIGRIS Power supply is removed or inserted this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITION…
1.3.6.1.4.1.5.1.1.5.6.26NodeaccRmFanStatTrapIf the fan in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEX…
1.3.6.1.4.1.5.1.1.5.6.27NodeaccRmDcStatTrapIf the AC componemt in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDIT…
1.3.6.1.4.1.5.1.1.5.6.28NodeaccRmAcStatTrapIf the DC componemt in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARI…
1.3.6.1.4.1.5.1.1.5.6.29NodeaccRmPwr1PresTrapIf the power supply is removed or installed this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: {…
1.3.6.1.4.1.5.1.1.5.6.30NodeaccRmPwrFan1TrapIf the Tigris power supply fan fails or recovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIAB…
1.3.6.1.4.1.5.1.1.5.6.31NodeaccRmPwrDc1TrapIf the Tigris power supply DC Component fails or recovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TE…
1.3.6.1.4.1.5.1.1.5.6.32NodeaccRmPwrAc1TrapIf the Tigris power supply AC Component fails or recovered this trap is generated. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: {…
1.3.6.1.4.1.5.1.1.5.6.33NodeaccRmEalm2TrapTrap indicating the external 2nd alarm status of the fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCard…
1.3.6.1.4.1.5.1.1.5.6.34NodeaccRmEalm1TrapTrap indicating the external 1st alarm status of the fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCard…
1.3.6.1.4.1.5.1.1.5.6.35NodeaccRmChasFanPresTrapTrap indicating the status of the chasis fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg …
1.3.6.1.4.1.5.1.1.5.6.36NodeaccRmChasFanIndTrapTrap indicating the status of the chasis fan whether it failed or recovered. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VAR…
1.3.6.1.4.1.5.1.1.5.6.37NodeaccRmLowMemTrapThis indicates very clearly that the Memory is very low and the admin has to do some dagnostics and take a quick action on the various memory critical issues f…
1.3.6.1.4.1.5.1.1.5.6.38NodeaccRmLanDiagsTrapWhen the diagnostics on the particular LAN slot fails this trap is generated. Indicating that there is some problem with that interface. SEVERITY-DEFAULT: Crit…
1.3.6.1.4.1.5.1.1.5.6.39NodeaccRmWanDiagsTrapWhen the diagnostics on the particular WAN slot fails this trap is generated. Indicating that there is some problem with that interface. SEVERITY-DEFAULT: Crit…
1.3.6.1.4.1.5.1.1.5.6.40NodeaccRmCardDiagsTrapWhen the diagnostics on the particular CARD slot fails this trap is generated. Indicating that there is some problem with that CARD. SEVERITY-DEFAULT: Critical…
1.3.6.1.4.1.5.1.1.5.6.41NodeaccRmResetTrapThis trap is to prompt the admin to reset the router as he would have changed some settings and they will be effective only after a reset for example change/de…
1.3.6.1.4.1.5.1.1.5.6.42NodeaccRmIdbTrapSEVERITY-DEFAULT: Indeterminate EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0
1.3.6.1.4.1.5.1.1.5.6.43NodeaccRmLdngElemManTrapBrowser loading Element Manager at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE…
1.3.6.1.4.1.5.1.1.5.6.44NodeaccRmInterFileJavaManTrapIntermediate file sent to Java Manager %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PC…
1.3.6.1.4.1.5.1.1.5.6.45NodeaccRmBrowLdngSetupWizTrapBrowser loading Java Setup Wizard at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAU…
1.3.6.1.4.1.5.1.1.5.6.46NodeaccRmConfWizLddTrapConfiguration Wizard is being loaded by the browser at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCard…
1.3.6.1.4.1.5.1.1.5.6.47NodeaccRmPriConfScrTrapPrimary config script sent to Configuration Wizard at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardS…
1.3.6.1.4.1.5.1.1.5.6.48NodeaccRmInstAccAppLddTrapInstant Access applet is being loaded by the browser at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCar…