CDM-570L
47 objects
Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems.
Imported Objects
| CDM-570 | cdm570 cdm570AlarmMask cdm570Alarms cdm570Conformance cdm570ODU cdm570ODUParams cdm570SystemEquipmentID |
| ComtechEFData | comtechEFData |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6247.24 | Identitycdm570 | Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems. | ||
| 1.3.6.1.4.1.6247.24.1.1.2.7 | Scalarcdm570LBUCOption | read-only | current | BUC option, where: 0 = None 1 = 100 watt 2 = 150 watt |
| 1.3.6.1.4.1.6247.24.1.2.7.9 | Scalarcdm570LAlarmMaskBUC | read-write | current | BUC alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.7.10 | Scalarcdm570LAlarmMaskLNB | read-write | current | LNB alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.8.1 | Nodecdm570LBUC | |||
| 1.3.6.1.4.1.6247.24.1.2.8.1.1 | Scalarcdm570LBUCDCPower | read-write | current | BUC power control, where: 0 = Disable BUC DC Power 1 = Enable BUC DC Power |
| 1.3.6.1.4.1.6247.24.1.2.8.1.2 | Nodecdm570LBUCFSK | |||
| 1.3.6.1.4.1.6247.24.1.2.8.1.2.1 | Scalarcdm570LBUCComms | read-write | current | Enables or disables communication, via the FSK link, with an externally connected Block Up Converted (BUC), where: 0 = Disabled 1 = Enabled |
| 1.3.6.1.4.1.6247.24.1.2.8.1.2.2 | Scalarcdm570LBUCAddress | read-write | current | Indicates the BUC address, between 1 and 15. |
| 1.3.6.1.4.1.6247.24.1.2.8.1.2.3 | Scalarcdm570LBUCRFOutput | read-write | current | Indicates BUC output enable, where: 0 = Off (output disabled) 1 = On (output enabled) |
| 1.3.6.1.4.1.6247.24.1.2.8.1.3 | Scalarcdm570LBUC10MHzReference | read-write | current | Enables or disables the 10 MHz frequency reference to the BUC, where: 0 = Disabled 1 = Enabled |
| 1.3.6.1.4.1.6247.24.1.2.8.1.4 | Nodecdm570LBUCAlarm | |||
| 1.3.6.1.4.1.6247.24.1.2.8.1.4.1 | Scalarcdm570LBUCHighCurrentLimit | read-write | current | BUC high current limit, between 500 and 4000 mA. |
| 1.3.6.1.4.1.6247.24.1.2.8.1.4.2 | Scalarcdm570LBUCLowCurrentLimit | read-write | current | BUC low current limit, between 0 and 3000 mA. BUC low current limit must not exceed BUC high current limit. |
| 1.3.6.1.4.1.6247.24.1.2.8.1.5 | Nodecdm570LBUCLO | |||
| 1.3.6.1.4.1.6247.24.1.2.8.1.5.1 | Scalarcdm570LBUCLOFrequency | read-write | current | BUC transmit LO frequency in the range of 3000 to 65000 MHz. Setting 0 disables this feature. Terminal Frequency = BUC_LO +/- Tx_Frequency (depending on LO mix… |
| 1.3.6.1.4.1.6247.24.1.2.8.1.5.2 | Scalarcdm570LBUCLOMix | read-write | current | BUC LO frequency mix, where: 0 = Low-side mix 1 = High-side mix |
| 1.3.6.1.4.1.6247.24.1.2.8.2 | Nodecdm570LLNB | |||
| 1.3.6.1.4.1.6247.24.1.2.8.2.1 | Scalarcdm570LLNBDCPower | read-write | current | LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage |
| 1.3.6.1.4.1.6247.24.1.2.8.2.2 | Scalarcdm570LLNB10MHzReference | read-write | current | LNB 10MHz frequency reference, where: 0 = Disable LNB 10MHz reference 1 = Enable LNB 10MHz reference |
| 1.3.6.1.4.1.6247.24.1.2.8.2.3 | Nodecdm570LLNBAlarm | |||
| 1.3.6.1.4.1.6247.24.1.2.8.2.3.1 | Scalarcdm570LLNBHighCurrentLimit | read-write | current | LNB upper alarm limit for current, between 50 and 600 mA. |
| 1.3.6.1.4.1.6247.24.1.2.8.2.3.2 | Scalarcdm570LLNBLowCurrentLimit | read-write | current | LNB lower alarm limit for current, between 10 and 400 mA. |
| 1.3.6.1.4.1.6247.24.1.2.8.2.4 | Nodecdm570LLNBLO | |||
| 1.3.6.1.4.1.6247.24.1.2.8.2.4.1 | Scalarcdm570LLNBLOFrequency | read-write | current | LNB receieve LO frequency, in the range of 3000 to 65000 MHz. Setting a 0 disables the feature. Terminal Frequency = LNB_LO +/- Rx_Frequency (depending on High… |
| 1.3.6.1.4.1.6247.24.1.2.8.2.4.2 | Scalarcdm570LLNBLOMix | read-write | current | LO frequency mix, where: 0 = Low-side mix 1 = High-side mix |
| 1.3.6.1.4.1.6247.24.1.3.1.4 | Scalarcdm570LODUAlarms | read-only | current | ODU Faults Value Description of status parameter 0 No ODU faults 1 BUC PLL 3 BUC current 5 BUC voltage 7 LNB current 9 LNB voltage 11 BUC temperature 13 BUC ch… |
| 1.3.6.1.4.1.6247.24.1.3.6.1 | Nodecdm570LBUCParams | |||
| 1.3.6.1.4.1.6247.24.1.3.6.1.1 | Scalarcdm570LBUCCurrent | read-only | current | Indicates the value of the BUC current, between 0 and 9999 mA. Units = mA. |
| 1.3.6.1.4.1.6247.24.1.3.6.1.2 | Scalarcdm570LBUCVoltage | read-only | current | Indicates the value ofthe BUC voltage, between 0 and 64 volts in 0.1 volts. Units = 0.1 volts. |
| 1.3.6.1.4.1.6247.24.1.3.6.1.3 | Scalarcdm570LBUCTemperature | read-only | current | Indicates the BUC temperature in degrees Celsius. If not available, response is -99. Note: This query is only valid when FSK and BUC power are turned On. |
| 1.3.6.1.4.1.6247.24.1.3.6.1.4 | Scalarcdm570LBUCSoftwareVersion | read-only | current | Indicates the BUC software version, between 1 and 15. If not available, response is 0. |
| 1.3.6.1.4.1.6247.24.1.3.6.1.5 | Scalarcdm570LBUCPLLAlarm | read-only | current | BUC PLL lock state, where: 0 = Locked 1 = Unlocked 9 = Unavailable |
| 1.3.6.1.4.1.6247.24.1.3.6.1.6 | Scalarcdm570LBUCPowerLevel | read-only | current | BUC output power level in 0.1 watts. Units = 0.1 watts. Returns 0 when FSK and BUC power are not enabled. |
| 1.3.6.1.4.1.6247.24.1.3.6.1.7 | Scalarcdm570LBUCTerminalTxFrequency | read-only | current | Terminal Tx Frequency = BUC_LO +/- Tx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if BUC LO is zero. |
| 1.3.6.1.4.1.6247.24.1.3.6.2 | Nodecdm570LLNBParams | |||
| 1.3.6.1.4.1.6247.24.1.3.6.2.1 | Scalarcdm570LLNBCurrent | read-only | current | Indicates the value of the LNB current, between 0 and 999 mA. |
| 1.3.6.1.4.1.6247.24.1.3.6.2.2 | Scalarcdm570LLNBVoltage | read-only | current | Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0. |
| 1.3.6.1.4.1.6247.24.1.3.6.2.3 | Scalarcdm570LLNBTerminalRxFrequency | read-only | current | Terminal Rx frequency = LNB LO +/- Rx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if LNB_LO is zero. |
| 1.3.6.1.4.1.6247.24.2 | Nodecdm570Notifications | |||
| 1.3.6.1.4.1.6247.24.2.0 | Nodecdm570NotificationsPrefix | |||
| 1.3.6.1.4.1.6247.24.2.0.4 | Notificationcdm570LODUAlarm | current | CDM-570L BUC and LNB ODU Alarm Trap | |
| 1.3.6.1.4.1.6247.24.3.3 | Nodecdm570LGroups | |||
| 1.3.6.1.4.1.6247.24.3.3.1 | Groupcdm570LObjectsGroup | current | CDM-570L Objects Group. | |
| 1.3.6.1.4.1.6247.24.3.3.2 | Groupcdm570LNotificationsGroup | current | CDM-570L Notifications Group. | |
| 1.3.6.1.4.1.6247.24.3.4 | Nodecdm570LCompliances | |||
| 1.3.6.1.4.1.6247.24.3.4.1 | Compliancecdm570LCompliance | current | CDM-570L Compliance. |