CONV-MIB
29 objects
No module-level DESCRIPTION found.
Imported Objects
| CXProduct-SMI | Alias cxConv |
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.8.1 | TablecxConvTable | not-accessible | mandatory | Provides configuration information and attributes of each of the module's convergence ports. The table contains two rows of default entries; some of these entr… |
| 1.3.6.1.4.1.495.2.1.6.8.1.1 | RowcxConvEntry | not-accessible | mandatory | |
| 1.3.6.1.4.1.495.2.1.6.8.1.1.1 | ColumncxConvPort | read-only | mandatory | Identifies the number of a specific convergence port. This number acts as an index to this and the cxFwkCircuitTable. Range of Values: 1 - 32 Default Value: No… |
| 1.3.6.1.4.1.495.2.1.6.8.1.1.2 | ColumncxConvPortAlias | read-write | mandatory | Determines a textual name (alias), assigned by the network administrator, which identifies a particular convergence port. The alias is used by the routing and … |
| 1.3.6.1.4.1.495.2.1.6.8.1.1.3 | ColumncxConvRowStatus | read-write | mandatory | Determines the status of the objects in a table row. Options: valid (1): values are enabled invalid (2) row is flagged, after next reset values will be disable… |
| 1.3.6.1.4.1.495.2.1.6.8.1.1.4 | ColumncxConvIfIndex | read-only | mandatory | Identifies the table row that contains configuration or monitoring objects for a specific type of physical interface. Range of Values: 1 to the number of entri… |
| 1.3.6.1.4.1.495.2.1.6.8.1.1.5 | ColumncxConvState | read-write | mandatory | Determines whether the convergence port is active (on). When the object is set to on, transmission can begin over the port; when the object is set to off trans… |
| 1.3.6.1.4.1.495.2.1.6.8.1.1.6 | ColumncxConvCompression | read-write | mandatory | Determines whether the port is linked to a compression port. If the port is not linked to a compression port the value is 0. If the port is linked to a compres… |
| 1.3.6.1.4.1.495.2.1.6.8.1.1.7 | ColumncxConvCompCompatibility | read-write | mandatory | Determines the data compression synchronization algorithm. When the CX1000 interfaces with Memotec models CL2800, CL5050, CL5200, CL5300, or CL5500, this objec… |
| 1.3.6.1.4.1.495.2.1.6.8.2 | TablecxFwkCircuitTable | not-accessible | mandatory | Provides the attributes of the WAN service(s) used and the circuits established by each convergence port. It also identifies statistical information about the … |
| 1.3.6.1.4.1.495.2.1.6.8.2.1 | RowcxFwkCircuitEntry | not-accessible | mandatory | |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.1 | ColumncxFwkCircuitPort | read-only | mandatory | Identifies the convergence port by a unique index number. This number acts as an index for this and the cxConvTable. Range of Values: 1 to the number of conver… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.2 | ColumncxFwkCircuitState | read-only | mandatory | Identifies the current state of the circuit between the convergence port and the destination port. Options: opened (1): The circuit is active closed (2): The c… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.3 | ColumncxFwkCircuitRowStatus | read-write | mandatory | Determines the status of the objects in a table row. Options: invalid (1): row is flagged, after next reset the values will be disabled and the row will be del… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.4 | ColumncxFwkServiceType | read-write | mandatory | Determines the WAN service used. At the present time, frame relay is the only WAN service available. Options: frameRelay (1) notSpecified (256) Default Value: … |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.5 | ColumncxFwkServiceProtocol | read-write | mandatory | Identifies the type of connection the WAN service uses. At the present time, Permanent Virtual Circuit (PVC) is the only type of connection available. Options … |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.6 | ColumncxFwkServiceName | read-only | mandatory | Identifies the textual name of the WAN service used. The system updates the name automatically when it selects a WAN service for transmission. Frame Relay is t… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.7 | ColumncxFwkDestAddress | read-only | mandatory | Identifies the address used to reach the WAN service provider. Range of Values: 20 octets, each octet ranging from 00 to FF. Default Value: None |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.8 | ColumncxFwkDestAlias | read-write | mandatory | Determines a unique textual name (assigned by a network administrator) identifying the destination frame relay circuit. Range of Values: 0-16 alphanumeric char… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.9 | ColumncxFwkServiceCircuitMdu | read-write | mandatory | Determines the maximum size of the data unit (in octets) that may be transmitted over the WAN circuit. Range of Values: 0 to 8192 Default Value: 1600 Configura… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.10 | ColumncxFwkServiceCost | read-write | mandatory | Determines the cost of the WAN service. Cost is typically inverse to the throughput. The smaller the number, the greater the throughput on the port. A value of… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.11 | ColumncxFwkServiceCardId | read-only | mandatory | Identifies the number of the chassis slot that contains the WAN service (FR600). This object is not applicable in the CX900 architecture. Range of Values: 1-16… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.12 | ColumncxFwkServiceSapId | read-only | mandatory | Identifies the ID of the WAN service's SAP (service access point) that the convergence port uses to establish the circuit. This object is not used if there is … |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.13 | ColumncxFwkServiceRouteRef | read-write | mandatory | Determines a routing reference number. This number provides a reference for WAN service providers that offer multiplexing (it is required in situations where m… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.15 | ColumncxFwkStatsInternalErrors | read-only | mandatory | Identifies the number of internal errors recognized by the convergence port. Range of Values: 1 to 4, 294, 967, 295 Default Value: 0 |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.16 | ColumncxFwkStatsRegistrationErrors | read-only | mandatory | Identifies the number of errors that occurred when the convergence port attempted to register itself to the framework. Range of Values: 1 to 4, 294, 967, 295 D… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.17 | ColumncxFwkStatsQueryErrors | read-only | mandatory | Identifies the number of times the convergence port requested a service that was not available. Range of Values: 1 to 4, 294, 967, 295 Default Value: 0 |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.18 | ColumncxFwkStatsOpenErrors | read-only | mandatory | Identifies the number of errors that occurred when the convergence port attempted to establish a connection with a WAN service. A value here may indicate conge… |
| 1.3.6.1.4.1.495.2.1.6.8.2.1.19 | ColumncxFwkStatsResets | read-only | mandatory | Identifies the number of resets received from the WAN service. A large value here may signify a breakdown on the bus or the WAN circuit. Range of Values: 1 to … |