CXCFG-BR-MIB
19 objects
No module-level DESCRIPTION found.
Imported Objects
| CXProduct-SMI | Alias cxCfgDot1dBase cxCfgSrBase |
| RFC-1212 | OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.14.1 | ScalarcxCfgDot1dBaseNumOfDBFilterEntries | read-write | mandatory | Determines the number of entries in the filtering database. Available RAM is the parameter. Range of Values: None Default Value: None Configuration Changed: Ad… |
| 1.3.6.1.4.1.495.2.1.6.14.2 | ScalarcxCfgDot1dBaseNumOfStaticDBFilterEntries | read-write | mandatory | Determines the number of static entries in the filtering database. Available RAM is the parameter. Range of Values: None Default Value: None Configuration Chan… |
| 1.3.6.1.4.1.495.2.1.6.14.3 | TablecxCfgDot1dBasePortTable | not-accessible | mandatory | A table that contains basic information about every port that is associated with this bridge. |
| 1.3.6.1.4.1.495.2.1.6.14.3.1 | RowcxCfgDot1dBasePortEntry | not-accessible | mandatory | Contains configuration information for each port of the bridge. |
| 1.3.6.1.4.1.495.2.1.6.14.3.1.1 | ColumncxCfgDot1dBasePort | read-only | mandatory | Displays the port number. Options: The acceptable values depend on the type of device that you are configuring. In the CX900 architecture: 11, 21, 31, 41, 51, … |
| 1.3.6.1.4.1.495.2.1.6.14.3.1.2 | ColumncxCfgDot1dBasePortIfIndex | read-only | mandatory | Displays the table row that contains configuration or monitoring objects for a specific type of physical interface. Range of Values: From 1 to the total number… |
| 1.3.6.1.4.1.495.2.1.6.14.3.1.3 | ColumncxCfgDot1dBasePortSubnetworkSapAlias | read-write | mandatory | Specifies a name (alias) for the physical or convergence port to which this port binds in order to establish a circuit for transmission. This value must match … |
| 1.3.6.1.4.1.495.2.1.6.14.3.1.4 | ColumncxCfgDot1dBasePortRowStatus | read-write | mandatory | Determines the status of the objects in a table row. Options: invalid (1): Row is flagged; after the next reset the values will be disabled and the row will be… |
| 1.3.6.1.4.1.495.2.1.6.14.3.1.5 | ColumncxCfgDot1dBasePortState | read-write | mandatory | Determines the state of the STP port. Options: On (1): The STP port is set to on. Off (2): The STP port is set to off. OnEther (3): The Ethernet STP port will … |
| 1.3.6.1.4.1.495.2.1.6.14.3.1.6 | ColumncxCfgDot1dBasePortPriority | read-write | mandatory | Determines the filtering/forwarding action and the forwarding priority for data sent from the STP bridge. Options: discard (1): Do not forward the data. forwar… |
| 1.3.6.1.4.1.495.2.1.6.14.4 | ScalarcxCfgDot1dBaseMibLevel | read-only | mandatory | Used to determine current MIB module release supported by the agent. Object is in decimal. |
| 1.3.6.1.4.1.495.2.1.6.17.1 | TablecxCfgSrBasePortTable | not-accessible | mandatory | A table that contains basic information about every port that is associated with this SR bridge. |
| 1.3.6.1.4.1.495.2.1.6.17.1.1 | RowcxCfgSrBasePortEntry | not-accessible | mandatory | Configuration information for each port of the SR bridge. |
| 1.3.6.1.4.1.495.2.1.6.17.1.1.1 | ColumncxCfgSrBasePort | read-only | mandatory | Displays the port number. Options: The acceptable values depend on the type of device that you are configuring. In the CX 900 architecture: 11, 21, 31, 41, 51,… |
| 1.3.6.1.4.1.495.2.1.6.17.1.1.2 | ColumncxCfgSrBasePortIfIndex | read-only | mandatory | Displays the table row that contains configuration or monitoring objects for a specific type of physical interface. Range of Values: From 1 to the total number… |
| 1.3.6.1.4.1.495.2.1.6.17.1.1.3 | ColumncxCfgSrBasePortSubnetworkSapAlias | read-write | mandatory | Specifies a name (alias) for the physical or convergence port to which this SR port binds in order to establish a circuit for transmission. This value must mat… |
| 1.3.6.1.4.1.495.2.1.6.17.1.1.4 | ColumncxCfgSrBasePortRowStatus | read-write | mandatory | Determines the status of the objects in a table row. Options: invalid (1): Row is flagged. After the next reset the values will be disabled and the row will be… |
| 1.3.6.1.4.1.495.2.1.6.17.1.1.5 | ColumncxCfgSrBasePortState | read-write | mandatory | Determines the state of the SR port. You can control activity at the port by changing this value. Options: on (1): The SR port is set to on. off (2): The SR po… |
| 1.3.6.1.4.1.495.2.1.6.17.1.1.6 | ColumncxCfgSrBasePortPriority | read-write | mandatory | Determines the filtering/forwarding action and the forwarding priority for data sent from the SR bridge. Options: discard (1): Do not forward the data. forward… |