CXEthIo-MIB
31 objects
No module-level DESCRIPTION found.
Imported Objects
| CXProduct-SMI | Alias cxEthIo |
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.45.1 | TableethSapOprTable | not-accessible | mandatory | Provides configuration information for each Ethernet service access point and its associated hardware ports. It also provides statistical information about act… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1 | RowethSapOprEntry | not-accessible | mandatory | Provides the configuration of a particular Ethernet service access point and its associated hardware port. It also provides statistical information about activ… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.1 | ColumnethSapOprNumber | read-only | mandatory | Identifies the service access point by a numerical value. Each service access point is assigned a unique number. The number is assigned by the system. |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.2 | ColumnethSapOprAlias | read-only | mandatory | Identifies the textual name (Alias) of this service access point. Each service access point must have a unique name. Range of Values: 0-16 alphanumeric charact… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.3 | ColumnethSapOprConnectorType | read-only | mandatory | Identifies the connector type used for the hardware port. Options: auto (1): (connector type detected automatically) aui (2): tbaseT (3): 100baseT (4) 100 Mbs … |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.4 | ColumnethSapOprDataGenerator | read-write | mandatory | Determines whether the Data Generator is enabled. The Data Generator is used for testing purposes. Options: disabled (1) enabled (2) enabled-verify(3): The dat… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.5 | ColumnethSapOprGenFrames | read-write | mandatory | Determines the number of times a frame will be generated (for testing purposes). Frames are generated every 1 msec. If the value is set to zero, then frames wi… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.6 | ColumnethSapOprGenFrameSize | read-write | mandatory | Determines the size of the frames (in bytes) to be generated (for testing purposes). If the Data Generator is disabled, then this value is ignored. Range of Va… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.7 | ColumnethSapOprLoopbackType | read-only | mandatory | Determines whether the port performs remote loopback, local loopback or both. Options: none (1): Loopback is disabled. local (2): The Service Access Point asso… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.12 | ColumnethOprControlStats | write-only | mandatory | Determines whether the statistics for the hardware port will be cleared. When the clearSapStats option is selected all the counters for the port are cleared. O… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.14 | ColumnethStatOprLinkState | read-only | mandatory | Identifies whether the hardware port is available. If there is a problem with the port (e.g. a faulty connection) the value will be down. Options: up (1) down … |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.15 | ColumnethStatOprInFrames | read-only | mandatory | Identifies the total number of frames received by this port. The value indicates the activity at this interface. Range of Values: 0 to 4, 294, 967, 295 Default… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.16 | ColumnethStatOprInOctets | read-only | mandatory | Identifies the total number of octets received by this port. The value indicates the activity at this interface. Range of Values: 0 to 4, 294, 967, 295 Default… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.17 | ColumnethStatOprInErrors | read-only | mandatory | Identifies the total number of errors received by this port. Errors include overrun errors, non-octet errors, and CRC errors. A high count may indicate a hardw… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.18 | ColumnethStatOprInDiscards | read-only | mandatory | Identifies the total number of frames received and discarded due to errors or other conditions (i.e. busy, lack of receive buffers, frames received while port … |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.19 | ColumnethStatOprInBusyDiscards | read-only | mandatory | Identifies the total number of frames received and discarded as a result of a lack of receive buffers. A high count may indicate system resources are low. Rang… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.20 | ColumnethStatOprOutFrames | read-only | mandatory | Identifies the total number of frames transmitted by this port. Range of Values: 0 to 4, 294, 967, 295 Default Value: None |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.21 | ColumnethStatOprOutOctets | read-only | mandatory | Identifies the total number of octets transmitted by this port. Range of Values: 0 to 4, 294, 967, 295 Default Value: None |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.22 | ColumnethStatOprOutErrors | read-only | mandatory | Identifies the total number of errors transmitted by this port. The count includes Transmitter Underrun, Carrier sense Lost During Frame Transmission, Attempts… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.23 | ColumnethStatOprOutDiscards | read-only | mandatory | Identifies the total number of frames which were unsuccessfully transmitted due to a lack of transmit buffers. Range of Values: 0 to 4, 294, 967, 295 Default V… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.24 | ColumnethStatOprOutCSLostFrames | read-only | mandatory | Identifies the total number of transmitted frames for which the carrier sense lost condition was encountered during transmission. A high count may indicate tha… |
| 1.3.6.1.4.1.495.2.1.6.45.1.1.25 | ColumnethStatOprRxGenErrors | read-only | mandatory | Identifies the total number of frames received that contain errors (for a port that has enable-verify set in ethSapOprDataGenerator.) Range of Values: 0 to 4, … |
| 1.3.6.1.4.1.495.2.1.6.45.2 | TableethSapAdmTable | not-accessible | mandatory | Provides configuration information for each Ethernet service access point and its associated hardware port. Each row (entry) of the table corresponds to a part… |
| 1.3.6.1.4.1.495.2.1.6.45.2.1 | RowethSapAdmEntry | not-accessible | mandatory | Provides configuration information for a particular Ethernet service access point and its associated hardware port. |
| 1.3.6.1.4.1.495.2.1.6.45.2.1.1 | ColumnethSapAdmNumber | read-only | mandatory | Identifies the service access point by a number. Each service access point is assigned a unique number. The number is assigned by the system. |
| 1.3.6.1.4.1.495.2.1.6.45.2.1.2 | ColumnethSapAdmAlias | read-write | mandatory | Determines the textual name (alias) of this service access point. Each service access point is assigned a unique name. Range of Values: 0-16 alphanumeric chara… |
| 1.3.6.1.4.1.495.2.1.6.45.2.1.3 | ColumnethSapAdmConnectorType | read-write | mandatory | Identifies the connector type used for the hardware port. Options: auto (1): connector type detected automatically aui (2) tbaseT (3) 100baseT (4) 100 Mbs Ethe… |
| 1.3.6.1.4.1.495.2.1.6.45.2.1.4 | ColumnethSapAdmDataGenerator | read-write | mandatory | Determines whether the Data Generator is enabled. The Data Generator is used for testing purposes. Options: disabled (1) enabled.(2) enabled-verify.(3) The dat… |
| 1.3.6.1.4.1.495.2.1.6.45.2.1.5 | ColumnethSapAdmGenFrames | read-write | mandatory | Determines the number of times a frame will be generated (for testing purposes). Frames are generated every 1 msec. If the value is set to zero, then frames wi… |
| 1.3.6.1.4.1.495.2.1.6.45.2.1.6 | ColumnethSapAdmGenFrameSize | read-write | mandatory | Determines the size of the frames (in bytes) to be generated (for testing purposes). If the Data Generator is disabled, then this value is ignored. Range of Va… |
| 1.3.6.1.4.1.495.2.1.6.45.2.1.7 | ColumnethSapAdmLoopbackType | read-write | mandatory | Determines whether the port performs remote loopback, local loopback or both. Options: none (1): Loopback is disabled. local (2): The Service Access Point asso… |