MIB Viewer

CXMCVOX-MIB

537 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.495.2.1.1.2NodecxMcVox
1.3.6.1.4.1.495.2.1.1.2.1NodecxMcVoxGlobal
1.3.6.1.4.1.495.2.1.1.2.1NodecxMcVoxTrapStatusReports that there is a change in the functional state of the voice channel. cxMcVoxTrapStatus = 1 if the port is disabled cxMcVoxTrapStatus = 2 if the port is…
1.3.6.1.4.1.495.2.1.1.2.1.1ScalarcxMcVoxGlobalAdmPathLngread-writeobsoleteobsolete. The ReinitNet/ReinitPath commands have been replaced by ReinitRouting.
1.3.6.1.4.1.495.2.1.1.2.1.2ScalarcxMcVoxGlobalReinitPathread-writeobsoleteThe ReinitNet/ReinitPath commands have been replaced by ReinitRouting.
1.3.6.1.4.1.495.2.1.1.2.1.3ScalarcxMcVoxGlobalClearPathread-writedeprecatedPath ID no longer exists with the new voice routing scheme Determines whether to restore all administrative Path IDs to the default factory settings. The setti…
1.3.6.1.4.1.495.2.1.1.2.1.4ScalarcxMcVoxGlobalReinitNetread-writeobsoleteThe ReinitNet/ReinitPath commands have been replaced by ReinitRouting.
1.3.6.1.4.1.495.2.1.1.2.1.5ScalarcxMcVoxGlobalClearNetread-writedeprecatedNetwork ID no longer exists in the new voice routing scheme (Voice Routing or VR). Determines whether to restore all administrative routing entries (i.e. netwo…
1.3.6.1.4.1.495.2.1.1.2.1.6ScalarcxMcVoxGlobalAdmLocalIdread-writeoptionalDetermines the administrative ID (name) for the local voice station. Note: This object must be defined in order to obtain a successful voice connection. Range …
1.3.6.1.4.1.495.2.1.1.2.1.7ScalarcxMcVoxGlobalOpeLocalIdread-onlyoptionalDisplays the operative ID (name) for the local voice station. Note: This object must be defined in order to obtain a successful voice connection. You cannot mo…
1.3.6.1.4.1.495.2.1.1.2.1.8ScalarcxMcVoxGlobalTensionRingread-onlymandatoryDisplays the state of the ring generator power supply. The power supply resides on the ring generator card located on the voice I/O card. You cannot modify thi…
1.3.6.1.4.1.495.2.1.1.2.1.9ScalarcxMcVoxGlobalTensionDcread-onlymandatoryDisplays the state of the DC power supply on the voice I/O card. Options: down (1): The DC power supply on the voice I/O card is down. up (2):The DC power supp…
1.3.6.1.4.1.495.2.1.1.2.1.10ScalarcxMcVoxGlobalTrapRingread-writemandatoryDetermines if the ring generator power supply trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins…
1.3.6.1.4.1.495.2.1.1.2.1.11ScalarcxMcVoxGlobalTrapDcread-writemandatoryDetermines if the DC power supply trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins to monitor …
1.3.6.1.4.1.495.2.1.1.2.1.12ScalarcxMcVoxGlobalAdmGrpNbPollread-writedeprecatedThe maximum number of remote voice station(s) that the the local voice station polls within a single call request has been moved from the Global Parameters gro…
1.3.6.1.4.1.495.2.1.1.2.1.13ScalarcxMcVoxGlobalOpeGrpNbPollread-onlydeprecatedThe the maximum number of remote voice stations the local voice station polls with a single call request. has been moved from the Global Parameters group to th…
1.3.6.1.4.1.495.2.1.1.2.1.14ScalarcxMcVoxGlobalClearGrpread-writeoptionalDetermines whether to restore all administrative Group IDs to the default factory settings. The setting of this object is dynamic. When set to 'yes' all admini…
1.3.6.1.4.1.495.2.1.1.2.1.15ScalarcxMcVoxGlobalOpePathLngread-onlyobsoleteThe Operational Path Length commands are now in the Operational Path table.
1.3.6.1.4.1.495.2.1.1.2.1.16ScalarcxMcVoxGlobalReinitRoutingread-writeoptionalTriggers the reinitialization of the operative routing table. The setting of this object is dynamic. When set to 'yes', all administrative routing, path and gr…
1.3.6.1.4.1.495.2.1.1.2.1.17ScalarcxMcVoxGlobalForceDefConfigread-writeoptionalDetermines whether the default factory configuration will replace both the administrative and operative configurations. The setting of this object is dynamic. …
1.3.6.1.4.1.495.2.1.1.2.1.18ScalarcxMcVoxGlobalReinitPinTableread-writeoptionalSaves the PIN table configuration in non-volatile memory, but only enables it if the object cxMcVoxGlobalAdmEnablePinTable is set to 'yes'. Options: no (1) yes…
1.3.6.1.4.1.495.2.1.1.2.1.19ScalarcxMcVoxGlobalAdmEnablePinTableread-writeoptionalSpecifies whether the voice station verifies PIN (Personal Identification Numbers) codes before allowing a connection to be established. Options: no (1) yes (2…
1.3.6.1.4.1.495.2.1.1.2.1.20ScalarcxMcVoxGlobalOpeEnablePinTableread-onlyoptionalDisplays the operational state of PIN verification. Options: no (1) yes (2) Default Value: no (1)
1.3.6.1.4.1.495.2.1.1.2.1.21ScalarcxMcVoxGlobalReinitCodesTableread-writeoptionalCopy the planned zone code configuration table into active zone code table (non-volatile memory). Options: no (1) yes (2) Default Value: no (1)
1.3.6.1.4.1.495.2.1.1.2.1.22ScalarcxMcVoxGlobalAdmEnableCodesTableread-writeoptionalThe CX900 does not currently support this object. Specifies whether the voice station verifies incoming telephone codes against its internal remote translation…
1.3.6.1.4.1.495.2.1.1.2.1.23ScalarcxMcVoxGlobalOpeEnableCodesTableread-onlyoptionalThe CX900 does not currently support this object. Displays the operational state of the remote translation table. Options: no (1) yes (2) Default Value: none
1.3.6.1.4.1.495.2.1.1.2.1.24ScalarcxMcVoxGlobalSoftRevread-onlyoptionalDisplays the software revision of the local voice station . You cannot modify this object. It is a display that the software provides. Range of Values: a maxim…
1.3.6.1.4.1.495.2.1.1.2.1.100ScalarcxMcVoxGlobalGlmInBetwReqTimeread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 2000 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.1.101ScalarcxMcVoxGlobalGlmMaxTimeToTxReqread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 1500
1.3.6.1.4.1.495.2.1.1.2.1.102ScalarcxMcVoxGlobalGlmInBetwRespTimeread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.1.103ScalarcxMcVoxGlobalGlmMaxTimeToTxRespread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 1500
1.3.6.1.4.1.495.2.1.1.2.1.104ScalarcxMcVoxGlobalGlmVoiceSilenceTimeread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 100 to 60000 Default Value: 3000
1.3.6.1.4.1.495.2.1.1.2.1.105ScalarcxMcVoxGlobalGlmSupervSilenceTimeread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 1000 to 60000 Default Value: 3000
1.3.6.1.4.1.495.2.1.1.2.1.106ScalarcxMcVoxGlobalGsdAutoCnctDelayread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 1 to 20000 Default Value: 1
1.3.6.1.4.1.495.2.1.1.2.1.107ScalarcxMcVoxGlobalClearLclExtread-writeoptionalClears Local Extensions after the next Reset. Planned Local Extensions are cleared immediately. Options: no (1): Local Extensions are not cleared. yes (2): Loc…
1.3.6.1.4.1.495.2.1.1.2.1.108ScalarcxMcVoxGlobalClearRmtExtread-writeoptionalClears Remote Extensions after the next Reset. Planned Remote Extensions are cleared immediately. Options: no (1): Remote Extensions are not cleared. yes (2): …
1.3.6.1.4.1.495.2.1.1.2.1.109ScalarcxMcVoxGlobalWanSlotread-writemandatoryDetermines the slot number of the FR600 card that is performing Voice Routing with the new Voice Routing scheme. Range of Values: 1 to 16 Default Value: 1
1.3.6.1.4.1.495.2.1.1.2.1.110ScalarcxMcVoxGlobalNetNbDigitsread-writemandatoryDetermines the number of digits used to represent Local Extensions, Remote Extensions and Remote Extension group IDs. Range of Values: 1 to 4 Default Value: 3
1.3.6.1.4.1.495.2.1.1.2.1.111ScalarcxMcVoxMibLevelread-onlymandatoryUsed to determine current MIB module release supported by the agent. Object is in decimal.
1.3.6.1.4.1.495.2.1.1.2.1.112ScalarcxMcVoxGlobalRecogAccread-writemandatoryThis specifies whether to recognize the defined Access Code. With the option enabled, if the Access Code is recognized, it is stripped from the dialing digit f…
1.3.6.1.4.1.495.2.1.1.2.1.113ScalarcxMcVoxGlobalAccCoderead-writemandatoryDetermines the numeric code to access the international network. Range of Values: 1 to 5 numeric digits Default Value: 011 Configuration Changed: operational
1.3.6.1.4.1.495.2.1.1.2.1.114ScalarcxMcVoxGlobalAccCodeLngread-onlymandatoryDetermines the number of digits in the configured Access Code.
1.3.6.1.4.1.495.2.1.1.2.1.115ScalarcxMcVoxGlobalAdmPinCodeLngread-writemandatoryDetermines the administrative number of digits in all Personal Identification Numbers (PINs).
1.3.6.1.4.1.495.2.1.1.2.1.116ScalarcxMcVoxGlobalOpePinCodeLngread-onlymandatoryDetermines the operational number of digits in all Personal Identification Numbers (PINs).
1.3.6.1.4.1.495.2.1.1.2.1.117ScalarcxMcVoxGlobalClearHistoryTableread-writemandatoryDetermines whether to clear ALL logging information from the history table. Options: disable(1): No action enable(2): Clear history table completely
1.3.6.1.4.1.495.2.1.1.2.1.118ScalarcxMcVoxGlobalHistoryMaxNumberOfEntriesread-writemandatoryThe maximum number of entries in the history table.
1.3.6.1.4.1.495.2.1.1.2.1.119ScalarcxMcVoxGlobalHistoryPercentageFullread-writemandatoryThe percentage of the history table that must be filled before a trap is sent to the management station.
1.3.6.1.4.1.495.2.1.1.2.1.120ScalarcxMcVoxGlobalTrapHistoryread-writemandatoryDetermines if the call history trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins to monitor the…
1.3.6.1.4.1.495.2.1.1.2.1.121ScalarcxMcVoxGlobalLseTimerT2read-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.1.122ScalarcxMcVoxGlobalLseTimerT3read-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 550
1.3.6.1.4.1.495.2.1.1.2.1.123ScalarcxMcVoxGlobalExtBitMaskread-writemandatoryThis object is a bitmap that selects up to cxMcVoxGlobalNetNbDigits, which can be set up to 4 digits, corresponding to a bit that is set. The default value cor…
1.3.6.1.4.1.495.2.1.1.2.2TablecxMcVoxCfgTablenot-accessiblemandatoryVoice station configuration Table.
1.3.6.1.4.1.495.2.1.1.2.2NodecxMcVoxTrapRingReports that there is a change in the functional state of the ring generator power supply. cxMcVoxTrapRing = 2 if the ringing generator is good cxMcVoxTrapRing…
1.3.6.1.4.1.495.2.1.1.2.2.1RowcxMcVoxCfgEntrynot-accessiblemandatoryVoice station configuration row definition.
1.3.6.1.4.1.495.2.1.1.2.2.1.1ColumncxMcVoxCfgCardIndexread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.2.1.2ColumncxMcVoxCfgPortIndexread-onlymandatoryDisplays the number of the voice port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up…
1.3.6.1.4.1.495.2.1.1.2.2.1.3ColumncxMcVoxCfgDriverAdmUsedread-writemandatoryDetermines the administrative driver of the port. The driver controls which signals the port supports. A port can only support one type of driver at any one ti…
1.3.6.1.4.1.495.2.1.1.2.2.1.4ColumncxMcVoxCfgDriverOpeUsedread-onlymandatoryDisplays the operative driver currently running on the port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxC…
1.3.6.1.4.1.495.2.1.1.2.2.1.5ColumncxMcVoxCfgTrapOnLineread-writedeprecatedDetermines the state of the port's online trap. When set to 'enable', every time a fax or phone call begins (i.e. the port switches from online to offline), th…
1.3.6.1.4.1.495.2.1.1.2.2.1.6ColumncxMcVoxCfgTrapOffLineread-writedeprecatedDetermines the state of the port's offline trap. When set to 'enable', every time a fax or phone call ends ( i.e. the port switches from offline to online) the…
1.3.6.1.4.1.495.2.1.1.2.2.1.7ColumncxMcVoxCfgTrapStatusread-writemandatoryDetermines the state of the port's status trap. When set to 'enable', every time the functional state of the voice channel changes (i.e. up or down) the SNMP a…
1.3.6.1.4.1.495.2.1.1.2.2.1.8ColumncxMcVoxCfgTrapStateread-writedeprecatedDetermines the state of the port's outgoing calls trap. When set to 'enable', every time an outgoing call request is in process the SNMP agent generates a trap…
1.3.6.1.4.1.495.2.1.1.2.2.1.9ColumncxMcVoxCfgTestPortread-writeoptionalDetermines the state of the port's self test. When set to 'yes', this object triggers the port to intiate a self-test. The port examines various hardware compo…
1.3.6.1.4.1.495.2.1.1.2.2.1.10ColumncxMcVoxCfgToneTestread-writemandatoryDetermines the state of the port's standard tone test (1004Hz). When set to 'enable', this object triggers the port to perform a tone test. The port tests its …
1.3.6.1.4.1.495.2.1.1.2.2.1.11ColumncxMcVoxCfgReinitPortread-writeoptionalDetermines the port's reinitialization state. The setting of this object is dynamic. When set to 'yes', this object triggers the port to write all administrati…
1.3.6.1.4.1.495.2.1.1.2.2.1.12ColumncxMcVoxCfgClearPortread-writeoptionalDetermines whether to restore all administrative voice port configurations to the default factory settings. The setting of this object is dynamic. When set to …
1.3.6.1.4.1.495.2.1.1.2.2.1.14ColumncxMcVoxCfgOpeAcelpRevread-onlyoptionalDisplays the ACELP software revision currently running on the operative voice channel. Range of Values: 0 to 12 alphanumeric characters. You can use any combin…
1.3.6.1.4.1.495.2.1.1.2.2.1.15ColumncxMcVoxCfgCmdImmTestread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 4294967295 Default Value: 0
1.3.6.1.4.1.495.2.1.1.2.2.1.16ColumncxMcVoxCfgCmdTestread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 4294967295 Default Value: 0
1.3.6.1.4.1.495.2.1.1.2.2.1.17ColumncxMcVoxCfgMaxPktFrameread-writemandatoryThe number of voice packet included in a voice frame. Less voice packet there is in a frame, bigger is the bandwitdh overhead on the WAN link, but better is th…
1.3.6.1.4.1.495.2.1.1.2.2.1.18ColumncxMcVoxCfgMaxSkewread-writemandatoryThe number of msec of skew that the end-to-end synchronization algorithm must compensate.
1.3.6.1.4.1.495.2.1.1.2.3NodecxMcVoxStatAndLog
1.3.6.1.4.1.495.2.1.1.2.3NodecxMcVoxTrapDcReports that there is a change in the functional state of the DC power supply. cxMcVoxGlobalTensionDc = 2 if the DC power supply is good cxMcVoxGlobalTensionDc…
1.3.6.1.4.1.495.2.1.1.2.3.1TablecxMcVoxStatusTablenot-accessiblemandatoryVoice station status table.
1.3.6.1.4.1.495.2.1.1.2.3.1.1RowcxMcVoxStatusEntrynot-accessiblemandatoryVoice station status row definition.
1.3.6.1.4.1.495.2.1.1.2.3.1.1.1ColumncxMcVoxStatusCardNumberread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values: CX900: 1 to 6 CX100…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.2ColumncxMcVoxStatusPortNumberread-onlymandatoryDisplays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable …
1.3.6.1.4.1.495.2.1.1.2.3.1.1.3ColumncxMcVoxStatusPortStatusread-onlymandatoryDisplays the functional status of the port. You cannot modify this object. It is a display that the software provides. Options: disable (1): port is not functi…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.4ColumncxMcVoxStatusHookLocalread-onlymandatoryDisplays the state of the local port's ability to establish a connection. When the status shows 'on', the port is idle and ready to transmit. You cannot modify…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.5ColumncxMcVoxStatusHookRemread-onlymandatoryDisplays the state of the remote port's ability to establish a connection. When the status shows 'on', the remote port is idle and ready to transmit. You canno…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.6ColumncxMcVoxStatusIoAccessread-onlymandatoryDisplays the results of the test that the CPU performs on the accessibility of the voice channel control registers residing on the voice I/O card. This object …
1.3.6.1.4.1.495.2.1.1.2.3.1.1.7ColumncxMcVoxStatusChannelAccessread-onlymandatoryDisplays the results of the test the CPU performs on the DPRAM. This object displays results from the self-test which you initiate using the object cxMcVoxCfgt…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.8ColumncxMcVoxStatusDspRamread-onlymandatoryDisplays the results of the test the DSP performs on the accessibility of the RAM memory on the voice I/O card. This object displays results from the self-test…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.9ColumncxMcVoxStatusDspDpramread-onlymandatoryDisplays the results of the test the DSP performs on the voice I/O card's DPRAM memory. This object displays results from the self-test which you initiate usin…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.10ColumncxMcVoxStatusSamplingTimeread-onlymandatoryDisplays the results of the test the DSP performs on the sampling rate of a voice stream. The DSP tests that the sampling rate is done at 8KHz. This object dis…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.11ColumncxMcVoxStatusWatchdogread-onlymandatoryDisplays the results of the test the CPU performs on the watchdog timer which resides on the voice I/O card. This object displays results from the self-test wh…
1.3.6.1.4.1.495.2.1.1.2.3.1.1.12ColumncxMcVoxStatusRemPortStatusread-onlymandatoryDisplays the channel number of the attached remote port. You cannot modify this object. Range of Values: 0-4294967295
1.3.6.1.4.1.495.2.1.1.2.3.1.1.13ColumncxMcVoxStatusInputDbmLevelread-onlymandatoryDisplays the current Dbm level of the input analog voice signal. You cannot modify this object. . Range of Values: 700 to 1050 (-30dBm to 5dBm) Default Value: …
1.3.6.1.4.1.495.2.1.1.2.3.1.1.14ColumncxMcVoxStatusPhyIfTyperead-onlymandatory
1.3.6.1.4.1.495.2.1.1.2.3.1.1.100ColumncxMcVoxStatusDspUtilizationread-onlymandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 1000 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.3.1.1.101ColumncxMcVoxStatusIOResetStateread-onlymandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: in-reset (1) normal (2) unknown (3)
1.3.6.1.4.1.495.2.1.1.2.3.2TablecxMcVoxEventTablenot-accessibledeprecatedOnLine/OffLine events table for incoming/outgoing calls.
1.3.6.1.4.1.495.2.1.1.2.3.2.1RowcxMcVoxEventEntrynot-accessibledeprecatedOnline/Offline events row definition.
1.3.6.1.4.1.495.2.1.1.2.3.2.1.1ColumncxMcVoxEventCardNumberread-onlydeprecatedDisplays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 4 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.3.2.1.2ColumncxMcVoxEventPortNumberread-onlydeprecatedDisplays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000…
1.3.6.1.4.1.495.2.1.1.2.3.2.1.3ColumncxMcVoxEventLogIndexread-onlydeprecatedDisplays the index number of the event log. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.3.2.1.4ColumncxMcVoxEventDateAndTimeOnLineread-onlydeprecatedDisplays the date and time of the last online event. An online event is any incoming or outgoing call that the voice station generates. The format of the displ…
1.3.6.1.4.1.495.2.1.1.2.3.2.1.5ColumncxMcVoxEventDateAndTimeOffLineread-onlydeprecatedDisplays the date and time of the last offline event. An offline event is any incoming or outgoing call that the voice station terminates. The format of the di…
1.3.6.1.4.1.495.2.1.1.2.3.2.1.6ColumncxMcVoxEventPhoneNumberread-onlydeprecatedDisplays the phone number (including any voice mail digits) the user enters to reach a remote telephone or fax machine. This object is irrelevant for incoming …
1.3.6.1.4.1.495.2.1.1.2.3.2.1.7ColumncxMcVoxEventLnkStateread-onlydeprecatedDisplays the status of the link to the remote telephone or fax machine. You cannot modify this object. Options: remUnavailable (1): the routing specifies a rem…
1.3.6.1.4.1.495.2.1.1.2.3.2.1.8ColumncxMcVoxEventPinread-onlydeprecatedDisplays the Personal Identification Number (PIN) that is validated against the local voice station card PIN number table. Range of Values: 2 to 8 numeric digi…
1.3.6.1.4.1.495.2.1.1.2.3.2.1.9ColumncxMcVoxEventClrEvtsread-writedeprecatedDetermines whether to clear ALL logging information from the Event group table. Options: no (1) yes (2) Default Value: no (1) Configuration Change: none
1.3.6.1.4.1.495.2.1.1.2.3.3TablecxMcVoxStateTablenot-accessibledeprecatedConnections table for outgoing calls.
1.3.6.1.4.1.495.2.1.1.2.3.3.1RowcxMcVoxStateEntrynot-accessibledeprecatedOutgoing call connection state row definition.
1.3.6.1.4.1.495.2.1.1.2.3.3.1.1ColumncxMcVoxStateCardNumberread-onlydeprecatedDisplays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values: CX900: 1 to 6 CX100…
1.3.6.1.4.1.495.2.1.1.2.3.3.1.2ColumncxMcVoxStatePortNumberread-onlydeprecatedDisplays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable …
1.3.6.1.4.1.495.2.1.1.2.3.3.1.3ColumncxMcVoxStateLogIndexread-onlydeprecatedDisplays the number of the table row containing objects used for monitoring the path state. You cannot modify this object. Range of Values: 1 to 4294967295 Def…
1.3.6.1.4.1.495.2.1.1.2.3.3.1.4ColumncxMcVoxStatePathIdread-onlydeprecatedDisplays the Path ID or Group ID that the user dials to access the remote telephone or fax machine. Displays the Path ID or Group ID that the user dials to acc…
1.3.6.1.4.1.495.2.1.1.2.3.3.1.5ColumncxMcVoxStateDateAndTimeread-onlydeprecatedDisplays the date and time the link associated with the Path/Group ID changed state (i.e. the call was initiated). The format of the display is as follows: Yea…
1.3.6.1.4.1.495.2.1.1.2.3.3.1.6ColumncxMcVoxStateLnkStateread-onlydeprecatedDisplays the status of the link to the remote telephone or fax machine. You cannot modify this object. Options: remUnavailable (1): the routing specifies a rem…
1.3.6.1.4.1.495.2.1.1.2.3.3.1.7ColumncxMcVoxStateRmtExtread-onlydeprecatedDisplays the Remote Extension or Group ID that the user dials to access the remote telephone or fax machine. You cannot modify this object. Range of Values: 1 …
1.3.6.1.4.1.495.2.1.1.2.4NodecxMcVoxHistoryTrapInforms the management station of the fact that the history table needs servicing.
1.3.6.1.4.1.495.2.1.1.2.4TablecxMcVoxPathAdmTablenot-accessibledeprecatedPlanned pathID table.
1.3.6.1.4.1.495.2.1.1.2.4.1RowcxMcVoxPathAdmEntrynot-accessibledeprecatedPlanned pathID row definition.
1.3.6.1.4.1.495.2.1.1.2.4.1.1ColumncxMcVoxPathAdmIndexread-onlydeprecatedDisplays the index number of the Path ID. You cannot modify this object. Range of Values: 1 to 300 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.4.1.2ColumncxMcVoxPathAdmRowStatusread-writedeprecatedDetermines the status of the objects in a table row. Options: invalid (1): Row is deleted from the table immediately, however values are still in effect until …
1.3.6.1.4.1.495.2.1.1.2.4.1.3ColumncxMcVoxPathAdmPathIdread-writedeprecatedDetermines the administrative numeric dialing code that the user enters to access the remote telephone or fax machine. Note: The length of the ID must match th…
1.3.6.1.4.1.495.2.1.1.2.4.1.4ColumncxMcVoxPathAdmRemStationIdread-writedeprecatedDetermines the administrative ID (name) of the remote voice station. Note: The remote voice station must exist in the Network Routing table before its ID can b…
1.3.6.1.4.1.495.2.1.1.2.4.1.5ColumncxMcVoxPathAdmHuntread-writedeprecatedDetermines the port numbers included in the administrative Hunt Group. A Hunt Group identifies multiple ports on a single remote voice station (as defined with…
1.3.6.1.4.1.495.2.1.1.2.4.1.6ColumncxMcVoxPathAdmLngread-writedeprecatedDetermines the length (in digits) of the administrative Path ID. Note: If you modify the current operative value to one that is a lower digit, the current oper…
1.3.6.1.4.1.495.2.1.1.2.5TablecxMcVoxPathOpeTablenot-accessibledeprecatedActive pathID table.
1.3.6.1.4.1.495.2.1.1.2.5.1RowcxMcVoxPathOpeEntrynot-accessibledeprecatedActive pathID row definition.
1.3.6.1.4.1.495.2.1.1.2.5.1.1ColumncxMcVoxPathOpeIndexread-onlydeprecatedDisplays the index number of the operational Path ID. You cannot modify this object. Range of Values: 1 to 300 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.5.1.2ColumncxMcVoxPathOpePathIdread-onlydeprecatedDisplays the operational Path ID. The Path ID is the numeric dialing code the user enters to gain access to the remote telephone or fax machine. You cannot mod…
1.3.6.1.4.1.495.2.1.1.2.5.1.3ColumncxMcVoxPathOpeRemStationIdread-onlydeprecatedDisplays the operational ID (name) of the remote voice station. Note: The remote voice station must exist in the Network Routing table before its ID can be def…
1.3.6.1.4.1.495.2.1.1.2.5.1.4ColumncxMcVoxPathOpeHuntread-onlydeprecatedDisplays the port numbers included in the operational Hunt Group. A Hunt Group identifies multiple ports on a single remote voice station (as defined with the …
1.3.6.1.4.1.495.2.1.1.2.5.1.5ColumncxMcVoxPathOpeLngread-onlydeprecatedDisplays the length (in digits) of the operative Path ID. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPath…
1.3.6.1.4.1.495.2.1.1.2.6TablecxMcVoxNetAdmTablenot-accessibledeprecatedPlanned NET entries.
1.3.6.1.4.1.495.2.1.1.2.6.1RowcxMcVoxNetAdmEntrynot-accessibledeprecatedPlanned NET row.
1.3.6.1.4.1.495.2.1.1.2.6.1.1ColumncxMcVoxNetAdmIndexread-onlydeprecatedDisplays the index number of the administrative network routing entry. You cannot modify this object. Range of Values: 1 to 300 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.6.1.2ColumncxMcVoxNetAdmRowStatusread-writedeprecatedDetermines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be…
1.3.6.1.4.1.495.2.1.1.2.6.1.3ColumncxMcVoxNetAdmRemStationIdread-writedeprecatedDetermines the administrative ID (name) of the remote voice station. Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capita…
1.3.6.1.4.1.495.2.1.1.2.6.1.4ColumncxMcVoxNetAdmLocalLnkStationread-writedeprecatedDetermines the slot number holding the local CPU board supporting the GMF software. This value is always '1' if the CPU is in the CX900 architecture. Range of …
1.3.6.1.4.1.495.2.1.1.2.6.1.5ColumncxMcVoxNetAdmRouteread-writedeprecatedDetermines the number that identifies the administrative link entry in the GMF (Gateway Mux Frame Relay). The network administrator assigns this number in sequ…
1.3.6.1.4.1.495.2.1.1.2.6.1.6ColumncxMcVoxNetAdmRemVoxStationread-writedeprecatedDetermines the slot number holding the remote CPU board that supports the voice software. This value is always '1' if the remote CPU is in the CX900 architectu…
1.3.6.1.4.1.495.2.1.1.2.7TablecxMcVoxNetOpeTablenot-accessibledeprecatedActive net entries table.
1.3.6.1.4.1.495.2.1.1.2.7.1RowcxMcVoxNetOpeEntrynot-accessibledeprecatedActive net entry row definition.
1.3.6.1.4.1.495.2.1.1.2.7.1.1ColumncxMcVoxNetOpeIndexread-onlydeprecatedDisplays the index number of the operative network routing entry. You cannot modify this object Range of Values: 1 to 300 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.7.1.2ColumncxMcVoxNetOpeRemStationIdread-onlydeprecatedDisplays the operative ID (name) of the remote voice station. You cannot modify this object. If you want to change the value you must modify the object cxMcVox…
1.3.6.1.4.1.495.2.1.1.2.7.1.3ColumncxMcVoxNetOpeLocalLnkStationread-onlydeprecatedDisplays the slot number holding the local CPU board supporting the GMF software. This value is always '1' if the CPU is in the CX900 architecture. You cannot …
1.3.6.1.4.1.495.2.1.1.2.7.1.4ColumncxMcVoxNetOpeRouteread-onlydeprecatedDisplays the number that identifies the operative link entry. The network administrator assigns this number to identify the route in the routing table. You can…
1.3.6.1.4.1.495.2.1.1.2.7.1.5ColumncxMcVoxNetOpeRemVoxStationread-onlydeprecatedDisplays the slot number holding the remote CPU board that supports the voice software. This value is always '1' if the remote CPU is in the CX900 architecture…
1.3.6.1.4.1.495.2.1.1.2.8NodecxMcVoxDriverAdm
1.3.6.1.4.1.495.2.1.1.2.8.1TablecxMcVoxEmAdmTablenot-accessiblemandatoryVoice station planned E&M Table.
1.3.6.1.4.1.495.2.1.1.2.8.1.1RowcxMcVoxEmAdmEntrynot-accessiblemandatoryVoice station planned E&M row definition.
1.3.6.1.4.1.495.2.1.1.2.8.1.1.1ColumncxMcVoxEmAdmCardUsedread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
1.3.6.1.4.1.495.2.1.1.2.8.1.1.2ColumncxMcVoxEmAdmPortUsedread-onlymandatoryDisplays the number of the voice port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable valu…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.3ColumncxMcVoxEmAdmPortStatusread-writemandatoryDetermines the functional status of the administrative E&M port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: …
1.3.6.1.4.1.495.2.1.1.2.8.1.1.4ColumncxMcVoxEmAdmVocoderread-writemandatoryDetermines the transmission speed (in bits per second) of the compressed voice stream on the administrative E&M port. Defining the speed also sets the ACELP vo…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.5ColumncxMcVoxEmAdmFaxBwread-writemandatoryDetermines the speed (in bits per second) of the FAX channel on the administrative E&M port. This value also determines the bandwidth required to pass FAX traf…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.6ColumncxMcVoxEmAdmAutoCnxread-writeobsoleteObsolete.
1.3.6.1.4.1.495.2.1.1.2.8.1.1.7ColumncxMcVoxEmAdmPathIdread-writedeprecatedPath IDs no longer exist in the new Voice Routing (VR) scheme. Determines the Path ID used for auto-connection on the administrative E&M port. The Path ID is a…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.8ColumncxMcVoxEmAdmTxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice transmissions on the administrative E&M port. The transmission gain can be modified in th…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.9ColumncxMcVoxEmAdmRxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice reception on the administrative E&M port. The reception gain can be modified in the admin…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.10ColumncxMcVoxEmAdmEchoCancelread-writemandatoryDetermines the state of echo cancellation on the administrative E&M port. When set to 'enable', at both the local and remote ends, echo cancellation stops echo…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.11ColumncxMcVoxEmAdmTyperead-writemandatoryDetermines the type of E&M interface on the administrative E&M port. Each of the five interface types has a unique signal-to-wire pattern. Make sure that you s…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.12ColumncxMcVoxEmAdmModeread-writemandatoryDetermines the signalling mode for the administrative E&M port. The signalling mode refers to the wires of the physical connection and how they are connected. …
1.3.6.1.4.1.495.2.1.1.2.8.1.1.13ColumncxMcVoxEmAdmDialTyperead-writemandatoryDetermines the dialing method of the administrative E&M port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.14ColumncxMcVoxEmAdmSignalTyperead-writemandatoryDetermines the type of signalling on the administrative E&M port. The signalling type refers to the line seizure technique Options: normal (1) delay (2) wink (…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.15ColumncxMcVoxEmAdmAc15Typeread-writemandatoryDetermines the type of AC15 signals the administrative E&M port uses to seize the line for transmission. This object is only relevant to E&M ports using the AC…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.16ColumncxMcVoxEmAdmAc15TimeOnread-writemandatoryDetermines the length of time, in milliseconds, the AC15 pulse remains on. This object is only relevant to E&M ports using the AC15 signalling type (as defined…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.17ColumncxMcVoxEmAdmAc15TimeOffread-writemandatoryDetermines the length of time, in milliseconds, the AC15 pulse remains off. This object is only relevant to E&M ports using the AC15 signalling type (as define…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.18ColumncxMcVoxEmAdmCnctTyperead-writemandatoryDetermines the method the administrative E&M port uses to make connections. Options: switched (1): the port connects each call according to the dialing code th…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.19ColumncxMcVoxEmAdmRingTyperead-writemandatoryDetermines the ring type of the administrative E&M port. The ring types provide different ring timing to match the different ring cycles in networks. Options: …
1.3.6.1.4.1.495.2.1.1.2.8.1.1.20ColumncxMcVoxEmAdmRmtExtread-writemandatoryDetermines the Remote Extension or Group Id used for auto-connection on the E&M port. The Remote Extension is a numeric dialing code that the user enters to ga…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.21ColumncxMcVoxEmAdmRmtIdread-writeoptionalDetermines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connect…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.22ColumncxMcVoxEmAdmTranspModeread-writemandatoryDetermines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party …
1.3.6.1.4.1.495.2.1.1.2.8.1.1.23ColumncxMcVoxEmAdmFaxEnableread-writemandatoryDetermines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software w…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.24ColumncxMcVoxEmAdmBroadcastread-writemandatoryCetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Def…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.25ColumncxMcVoxEmAdmImpedanceread-writemandatoryDisplays the input line impedance of the operative E&M interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohm…
1.3.6.1.4.1.495.2.1.1.2.8.1.1.26ColumncxMcVoxEmAdmVoiceConnectionread-onlymandatoryIndicates which voice path is provided by the E&M interface. Options: two-wires (1) four-wires (2)
1.3.6.1.4.1.495.2.1.1.2.8.2TablecxMcVoxFxsAdmTablenot-accessiblemandatory
1.3.6.1.4.1.495.2.1.1.2.8.2.1RowcxMcVoxFxsAdmEntrynot-accessiblemandatory
1.3.6.1.4.1.495.2.1.1.2.8.2.1.1ColumncxMcVoxFxsAdmCardUsedread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
1.3.6.1.4.1.495.2.1.1.2.8.2.1.2ColumncxMcVoxFxsAdmPortUsedread-onlymandatoryDisplays the number of the voice port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port CX1000: 1 o…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.3ColumncxMcVoxFxsAdmPortStatusread-writemandatoryDetermines the functional status of the administrative port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: disa…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.4ColumncxMcVoxFxsAdmVocoderread-writemandatoryDetermines the transmission speed (in bits per second) of the compressed voice stream on the administrative FXS port. Defining the speed also sets the ACELP vo…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.5ColumncxMcVoxFxsAdmFaxBwread-writemandatoryDetermines the speed (in bits per second) of the FAX channel on the administrative FXS port. This value also determines the bandwidth required to pass FAX traf…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.6ColumncxMcVoxFxsAdmAutoCnxread-writeobsoleteobsolete
1.3.6.1.4.1.495.2.1.1.2.8.2.1.7ColumncxMcVoxFxsAdmPathIdread-writedeprecatedPath IDs no longer exist with the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone o…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.8ColumncxMcVoxFxsAdmTxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice transmissions on the administrative FXS port. The transmission gain can be modified in th…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.9ColumncxMcVoxFxsAdmRxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice reception on the administrative FXS port. The reception gain can be modified in the admin…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.10ColumncxMcVoxFxsAdmEchoCancelread-writemandatoryDetermines the state of echo cancellation on the administrative FXS port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoe…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.11ColumncxMcVoxFxsAdmSignalingread-writemandatoryDetermines the type of signalling the administrative FXS port uses to seize the line. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-star…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.12ColumncxMcVoxFxsAdmTimeOnread-writeobsoleteobsolete
1.3.6.1.4.1.495.2.1.1.2.8.2.1.13ColumncxMcVoxFxsAdmTimeOffread-writeobsoleteobsolete
1.3.6.1.4.1.495.2.1.1.2.8.2.1.14ColumncxMcVoxFxsAdmCnctTyperead-writemandatoryDetermines the method the administrative FXS port uses to make connections. Options: switched (1): the port connects each call according to the dialing code th…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.15ColumncxMcVoxFxsAdmRingTyperead-writemandatoryDetermines the ring type of the administrative FXS port. The ring types provide different ring timing to match the different ring cycles in networks. Options: …
1.3.6.1.4.1.495.2.1.1.2.8.2.1.16ColumncxMcVoxFxsAdmImpedanceread-writemandatoryDetermines the input line impedance of the administrative FXS port. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) Configura…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.17ColumncxMcVoxFxsAdmDialTyperead-writemandatoryDetermines the dialing method of the administrative FXS port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.18ColumncxMcVoxFxsAdmDidSignalTyperead-writemandatoryNote: This object only applies to those ports with the object cxMcVoxFxsAdmSignaling set to 'did'. Determines the type of signaling on the administrative FXS p…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.19ColumncxMcVoxFxsAdmRmtExtread-writemandatoryDetermines the Remote Extension or Group Id used for auto-connection on the FXS port. The Remote Extension is a numeric dialing code that the user enters to ac…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.20ColumncxMcVoxFxsAdmRmtIdread-writeoptionalDetermines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection with fixed type conne…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.21ColumncxMcVoxFxsAdmTranspModeread-writemandatoryDetermines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party …
1.3.6.1.4.1.495.2.1.1.2.8.2.1.22ColumncxMcVoxFxsAdmFaxEnableread-writemandatoryDetermines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software w…
1.3.6.1.4.1.495.2.1.1.2.8.2.1.23ColumncxMcVoxFxsAdmBroadcastread-writemandatoryCetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Def…
1.3.6.1.4.1.495.2.1.1.2.8.3TablecxMcVoxFxoAdmTablenot-accessiblemandatorycx Voice Station Administrative FXO Table.
1.3.6.1.4.1.495.2.1.1.2.8.3.1RowcxMcVoxFxoAdmEntrynot-accessiblemandatorycx Voice Station Administrative FXO Entry
1.3.6.1.4.1.495.2.1.1.2.8.3.1.1ColumncxMcVoxFxoAdmCardUsedread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values CX900: 1 to 6 CX1000…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.2ColumncxMcVoxFxoAdmPortUsedread-onlymandatoryDisplays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable …
1.3.6.1.4.1.495.2.1.1.2.8.3.1.3ColumncxMcVoxFxoAdmPortStatusread-writemandatoryDetermines the functional status of the administrative port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: disa…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.4ColumncxMcVoxFxoAdmVocoderread-writemandatoryDetermines the transmission speed (in bits per second) of the compressed voice stream on the administrative FXO port. Defining the speed also sets the ACELP vo…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.5ColumncxMcVoxFxoAdmFaxBwread-writemandatoryDetermines the speed (in bits per second) of the FAX channel on the administrative FXO port. This value also determines the bandwidth required to pass FAX traf…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.6ColumncxMcVoxFxoAdmAutoCnxread-writeobsoleteobsolete
1.3.6.1.4.1.495.2.1.1.2.8.3.1.7ColumncxMcVoxFxoAdmPathIdread-writedeprecatedPath IDs no longer exist with the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone o…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.8ColumncxMcVoxFxoAdmTxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice transmission on the administrative FXO port. The transmission gain can be modified in the…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.9ColumncxMcVoxFxoAdmRxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice reception on the administrative FXO port. The reception gain can be modified in the admin…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.10ColumncxMcVoxFxoAdmEchoCancelread-writemandatoryDetermines the state of echo cancellation on the administrative FXO port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoe…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.11ColumncxMcVoxFxoAdmSignalingread-writemandatoryDetermines the type of signalling the administrative FXO port uses to seize the line. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-star…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.12ColumncxMcVoxFxoAdmCnctTyperead-writemandatoryDetermines the method the administrative FXO port uses to make connections. Options: switched (1): the port connects each call according to the dialing code th…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.13ColumncxMcVoxFxoAdmRingTyperead-writemandatoryDetermines the ring type of the administrative FXO port. The ring types provide different ring timing to match the different ring cycles in networks. Options: …
1.3.6.1.4.1.495.2.1.1.2.8.3.1.14ColumncxMcVoxFxoAdmImpedanceread-writemandatoryDetermines the input line impedance of the administrative FXO interface. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) Conf…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.15ColumncxMcVoxFxoAdmDialTyperead-writemandatoryDetermines the dialing method of the administrative FXO port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.16ColumncxMcVoxFxoAdmDidSignalTyperead-writemandatoryNote: This object only applies to those ports with the object cxMcVoxFxoAdmSignaling set to 'did'. Determines the type of signaling on the administrative FXO p…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.17ColumncxMcVoxFxoAdmRmtExtread-writemandatoryDetermines the Remote Extension or Group Id used for auto-connection on the FXO port. The Remote Extension is a numeric dialing code that the user enters to ga…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.18ColumncxMcVoxFxoAdmRmtIdread-writeoptionalDetermines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection with fixed type conne…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.19ColumncxMcVoxFxoAdmTranspModeread-writemandatoryDetermines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party …
1.3.6.1.4.1.495.2.1.1.2.8.3.1.20ColumncxMcVoxFxoAdmFaxEnableread-writemandatoryDetermines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software w…
1.3.6.1.4.1.495.2.1.1.2.8.3.1.21ColumncxMcVoxFxoAdmBroadcastread-writemandatoryCetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Def…
1.3.6.1.4.1.495.2.1.1.2.9NodecxMcVoxDriverOpe
1.3.6.1.4.1.495.2.1.1.2.9.1TablecxMcVoxEmOpeTablenot-accessiblemandatory
1.3.6.1.4.1.495.2.1.1.2.9.1.1RowcxMcVoxEmOpeEntrynot-accessiblemandatory
1.3.6.1.4.1.495.2.1.1.2.9.1.1.1ColumncxMcVoxEmOpeCardUsedread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
1.3.6.1.4.1.495.2.1.1.2.9.1.1.2ColumncxMcVoxEmOpePortUsedread-onlymandatoryDisplays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.3ColumncxMcVoxEmOpePortStatusread-onlymandatoryDisplays the functional status of the operative port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmpor…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.4ColumncxMcVoxEmOpeVocoderread-onlymandatoryDisplays the transmission speed (in bits per second) of the compressed voice stream on the operative E&M port. Defining the speed also sets the ACELP voice com…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.5ColumncxMcVoxEmOpeFaxBwread-writemandatoryDetermines the speed (in bits per second) of the FAX channel on the operative E&M port. This value also determines the bandwidth required to pass FAX traffic t…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.6ColumncxMcVoxEmOpeAutoCnxread-onlyobsoleteobsolete
1.3.6.1.4.1.495.2.1.1.2.9.1.1.7ColumncxMcVoxEmOpePathIdread-onlydeprecatedPath IDs no longer exist in the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or …
1.3.6.1.4.1.495.2.1.1.2.9.1.1.8ColumncxMcVoxEmOpeTxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice transmissions on the operative E&M port. The transmission gain can be modified in the adm…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.9ColumncxMcVoxEmOpeRxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice reception on the operative E&M port. The reception gain can be modified in the administra…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.10ColumncxMcVoxEmOpeEchoCancelread-onlymandatoryDisplays the state of echo cancellation on the operative E&M port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from …
1.3.6.1.4.1.495.2.1.1.2.9.1.1.11ColumncxMcVoxEmOpeTyperead-onlymandatoryDisplays the type of E&M interface of the operative E&M port. Each of the five interface types has a unique signal-to-wire pattern. Be sure to select the inter…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.12ColumncxMcVoxEmOpeModeread-onlymandatoryDisplays the signalling mode for the operative E&M port. The signalling mode refers to the wires of the physical connection and how they are connected. The mod…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.13ColumncxMcVoxEmOpeDialTyperead-onlymandatoryDisplays the dialing method of the operative E&M port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. …
1.3.6.1.4.1.495.2.1.1.2.9.1.1.14ColumncxMcVoxEmOpeSignalTyperead-onlymandatoryDisplays the type of signalling the operative E&M port uses to seize the line. You cannot modify this object. If you want to change the value you must modify t…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.15ColumncxMcVoxEmOpeAc15Typeread-onlymandatoryDisplays the type of AC15 signals the operative E&M port uses to seize the line for transmission. This object is only relevant to E&M ports using the AC15 sign…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.16ColumncxMcVoxEmOpeAc15TimeOnread-writemandatoryDetermines the length of time, in milliseconds, the AC15 pulse remains on. This object is only relevant to E&M ports using the AC15 signalling type (as defined…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.17ColumncxMcVoxEmOpeAc15TimeOffread-writemandatoryDetermines the length of time, in milliseconds, the AC15 pulse remains off. This object is only relevant to E&M ports using the AC15 signalling type (as define…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.18ColumncxMcVoxEmOpeCnctTyperead-onlymandatoryDisplays the method the operative E&M port uses to make connections. This object is only relevant to E&M ports using the AC15 signalling type (as defined using…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.19ColumncxMcVoxEmOpeRingTyperead-onlymandatoryDisplays the ring type of the operative E&M port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modif…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.20ColumncxMcVoxEmOpeRmtExtread-onlymandatoryDetermines the Remote Extension or Group Id used for auto-connection on the E&M port. The Remote Extension is a numeric dialing code that the user enters to ac…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.21ColumncxMcVoxEmOpeRmtIdread-onlyoptionalDisplays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connectio…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.22ColumncxMcVoxEmOpeTranspModeread-onlymandatoryDetermines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party …
1.3.6.1.4.1.495.2.1.1.2.9.1.1.23ColumncxMcVoxEmOpeFaxEnableread-onlymandatoryDisplays the state of the FAX on the operative E&M port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify thi…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.24ColumncxMcVoxEmOpeBroadcastread-onlymandatoryCetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Def…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.25ColumncxMcVoxEmOpeImpedanceread-writemandatoryDisplays the input line impedance of the operative E&M interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohm…
1.3.6.1.4.1.495.2.1.1.2.9.1.1.26ColumncxMcVoxEmOpeVoiceConnectionread-onlymandatoryIndicates which voice path is provided by the E&M interface. Options: two-wires (1) four-wires (2)
1.3.6.1.4.1.495.2.1.1.2.9.2TablecxMcVoxFxsOpeTablenot-accessiblemandatorycx Voice Station active FXS Table.
1.3.6.1.4.1.495.2.1.1.2.9.2.1RowcxMcVoxFxsOpeEntrynot-accessiblemandatorycx Voice Station active FXS Entry
1.3.6.1.4.1.495.2.1.1.2.9.2.1.1ColumncxMcVoxFxsOpeCardUsedread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
1.3.6.1.4.1.495.2.1.1.2.9.2.1.2ColumncxMcVoxFxsOpePortUsedread-onlymandatoryDisplays the number of the voice I/O port. You cannot modify this object Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000:…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.3ColumncxMcVoxFxsOpePortStatusread-onlymandatoryDisplays the functional status of the operative port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmpo…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.4ColumncxMcVoxFxsOpeVocoderread-onlymandatoryDisplays the transmission speed (in bits per second) of the compressed voice stream on the operative FXS port. Defining the speed also sets the ACELP voice com…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.5ColumncxMcVoxFxsOpeFaxBwread-writemandatoryDetermines the speed (in bits per second) of the FAX channel on the operative FXS port. This value also determines the bandwidth required to pass FAX traffic t…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.6ColumncxMcVoxFxsOpeAutoCnxread-onlyobsoleteObsolete
1.3.6.1.4.1.495.2.1.1.2.9.2.1.7ColumncxMcVoxFxsOpePathIdread-onlydeprecatedPath IDs no longer exist in the new Voice Routing (VR) scheme. The PathID was formerly used for auto-connection on the operative FXS port. The Path ID is a num…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.8ColumncxMcVoxFxsOpeTxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice transmissions on the operative FXS port. The transmission gain can be modified in the adm…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.9ColumncxMcVoxFxsOpeRxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice reception on the operative FXS port. The reception gain can be modified in the administra…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.10ColumncxMcVoxFxsOpeEchoCancelread-onlymandatoryDisplays the state of echo cancellation on the operative FXS port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from …
1.3.6.1.4.1.495.2.1.1.2.9.2.1.11ColumncxMcVoxFxsOpeSignalingread-onlymandatoryDisplays the type of signalling the operative FXS port uses to seize the line. You cannot modify this object. If you want to change the value you must modify t…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.12ColumncxMcVoxFxsOpeTimeOnread-onlyobsoleteObsolete
1.3.6.1.4.1.495.2.1.1.2.9.2.1.13ColumncxMcVoxFxsOpeTimeOffread-onlyobsoleteObsoleted
1.3.6.1.4.1.495.2.1.1.2.9.2.1.14ColumncxMcVoxFxsOpeCnctTyperead-onlymandatoryDisplays the method the operative FXS port uses to make connections. You cannot modify this object. If you want to change the value you must modify the object …
1.3.6.1.4.1.495.2.1.1.2.9.2.1.15ColumncxMcVoxFxsOpeRingTyperead-onlymandatoryDisplays the ring type of the operative FXS port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modif…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.16ColumncxMcVoxFxsOpeImpedanceread-writemandatoryDisplays the input line impedance of the operative FXS interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohm…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.17ColumncxMcVoxFxsOpeDialTyperead-onlymandatoryDisplays the dialing method of the operative FXS port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. …
1.3.6.1.4.1.495.2.1.1.2.9.2.1.18ColumncxMcVoxFxsOpeDidSignalTyperead-onlymandatoryDisplays the type of signaling on the operative FXS port. The signaling type refers to the line seizure technique. You cannot modify this object. If you want t…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.19ColumncxMcVoxFxsOpeRmtExtread-onlymandatoryDetermines the Remote Extension or Group Id used for auto-connection on the FXS port. The Remote Extension is a numeric dialing code that the user enters to ga…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.20ColumncxMcVoxFxsOpeRmtIdread-onlyoptionalDisplays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connectio…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.21ColumncxMcVoxFxsOpeTranspModeread-onlymandatoryDetermines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party …
1.3.6.1.4.1.495.2.1.1.2.9.2.1.22ColumncxMcVoxFxsOpeFaxEnableread-onlymandatoryDisplays the state of the FAX on the operative FXS port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify thi…
1.3.6.1.4.1.495.2.1.1.2.9.2.1.23ColumncxMcVoxFxsOpeBroadcastread-onlymandatoryCetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Def…
1.3.6.1.4.1.495.2.1.1.2.9.3TablecxMcVoxFxoOpeTablenot-accessiblemandatorycx Voice Station active FXO Table.
1.3.6.1.4.1.495.2.1.1.2.9.3.1RowcxMcVoxFxoOpeEntrynot-accessiblemandatorycx Voice Station active FXO Entry
1.3.6.1.4.1.495.2.1.1.2.9.3.1.1ColumncxMcVoxFxoOpeCardUsedread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000 1 to 8 Default: none
1.3.6.1.4.1.495.2.1.1.2.9.3.1.2ColumncxMcVoxFxoOpePortUsedread-onlymandatoryDisplays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.3ColumncxMcVoxFxoOpePortStatusread-onlymandatoryDisplays the functional status of the port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmportStatus o…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.4ColumncxMcVoxFxoOpeVocoderread-onlymandatoryDisplays the transmission speed (in bits per second) of the compressed voice stream on the operative FXO port. Defining the speed also sets the ACELP voice com…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.5ColumncxMcVoxFxoOpeFaxBwread-writemandatoryDetermines the speed (in bits per second) of the FAX channel on the operative FXO port. This value also determines the bandwidth required to pass FAX traffic t…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.6ColumncxMcVoxFxoOpeAutoCnxread-onlyobsoleteObsolete
1.3.6.1.4.1.495.2.1.1.2.9.3.1.7ColumncxMcVoxFxoOpePathIdread-onlydeprecatedPath IDs no longer exist in the new Voice Routing (VR) scheme. The PathID was formerly used for auto-connection on the operative FXO port. The Path ID is a num…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.8ColumncxMcVoxFxoOpeTxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice transmissions on the operative FXO port. The transmission gain can be modified in the adm…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.9ColumncxMcVoxFxoOpeRxGainread-writemandatoryDetermines the value defining the sound intensity (loudness) of voice reception on the operative FXO port. The reception gain can be modified in the administra…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.10ColumncxMcVoxFxoOpeEchoCancelread-onlymandatoryDisplays the state of echo cancellation on the operative FXO port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from …
1.3.6.1.4.1.495.2.1.1.2.9.3.1.11ColumncxMcVoxFxoOpeSignalingread-onlymandatoryDisplays the type of signalling the operative FXO port uses to seize the line. You cannot modify this object. If you want to change the value you must modify t…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.12ColumncxMcVoxFxoOpeCnctTyperead-onlymandatoryDisplays the method the operative FXO port uses to make connections. You cannot modify this object. If you want to change the value you must modify the object …
1.3.6.1.4.1.495.2.1.1.2.9.3.1.13ColumncxMcVoxFxoOpeRingTyperead-onlymandatoryDisplays the ring type of the operative FXO port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modif…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.14ColumncxMcVoxFxoOpeImpedanceread-writemandatoryDisplays the input line impedance of the operative FXO interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohm…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.15ColumncxMcVoxFxoOpeDialTyperead-onlymandatoryDisplays the dialing method of the operative FXO port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. …
1.3.6.1.4.1.495.2.1.1.2.9.3.1.16ColumncxMcVoxFxoOpeDidSignalTyperead-onlymandatoryDisplays the type of signaling on the operative FXO port. The signaling type refers to the line seizure technique. You cannot modify this object. If you want t…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.17ColumncxMcVoxFxoOpeRmtExtread-onlymandatoryDetermines the Remote Extension or Group Id used for auto-connection on the FXO port. The Remote Extension is a numeric dialing code that the user enters to ga…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.18ColumncxMcVoxFxoOpeRmtIdread-onlyoptionalDisplays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connectio…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.19ColumncxMcVoxFxoOpeTranspModeread-onlymandatoryDetermines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party …
1.3.6.1.4.1.495.2.1.1.2.9.3.1.20ColumncxMcVoxFxoOpeFaxEnableread-onlymandatoryDisplays the state of the FAX on the operative FXO port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify thi…
1.3.6.1.4.1.495.2.1.1.2.9.3.1.21ColumncxMcVoxFxoOpeBroadcastread-onlymandatoryCetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Def…
1.3.6.1.4.1.495.2.1.1.2.10TablecxMcVoxGrpIdAdmTablenot-accessiblemandatoryVoice Station Group Id identification Table.
1.3.6.1.4.1.495.2.1.1.2.10.1RowcxMcVoxGrpIdAdmEntrynot-accessiblemandatoryAssociates an entry in the GroupId table with a pathId-like identifier for that groupId.
1.3.6.1.4.1.495.2.1.1.2.10.1.1ColumncxMcVoxGrpIdAdmIndexread-onlymandatoryDisplays the index number of the administrative Group ID. You cannot modify this object. It is a display that the software provides. Range of Values: 1 to 32 D…
1.3.6.1.4.1.495.2.1.1.2.10.1.2ColumncxMcVoxGrpIdAdmread-writemandatoryDetermines the administrative Group ID. The Group ID is a dialing code that the user enters to gain access to a remote telephone or FAX machine. The group cont…
1.3.6.1.4.1.495.2.1.1.2.10.1.3ColumncxMcVoxGrpIdLenAdmread-onlymandatoryDetermines the length (in digits) of the administrative Group ID. Range of Values: 1 to 4 Default Value: 3 Configuration Changed: administrative
1.3.6.1.4.1.495.2.1.1.2.10.1.4ColumncxMcVoxGrpIdAdmRowStatusread-writemandatoryDetermines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be…
1.3.6.1.4.1.495.2.1.1.2.10.1.5ColumncxMcVoxGrpIdAdmNbPollread-writeoptionalDetermines the maximum number of remote voice stations in an Extension Group that the local voice station polls with a single call request. Note: This object i…
1.3.6.1.4.1.495.2.1.1.2.11TablecxMcVoxGrpIdOpeTablenot-accessiblemandatorycx Voice Station Group Id identification Table.
1.3.6.1.4.1.495.2.1.1.2.11.1RowcxMcVoxGrpIdOpeEntrynot-accessiblemandatoryAssociates an entry in the GroupId table with a pathId-like identifier for that groupId.
1.3.6.1.4.1.495.2.1.1.2.11.1.1ColumncxMcVoxGrpIdOpeIndexread-onlymandatoryDisplays the index number of the operative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.11.1.2ColumncxMcVoxGrpIdOperead-onlymandatoryDisplays the operative Group ID. The Group ID is a dialing code the user enters to gain access to the remote telephone or FAX machine. The Group ID contains up…
1.3.6.1.4.1.495.2.1.1.2.11.1.3ColumncxMcVoxGrpIdLenOperead-onlymandatoryDetermines the length (in digits) of the operative Group ID. You cannot moify this object. If you want to change the value you must modify the object cxMcVoxGr…
1.3.6.1.4.1.495.2.1.1.2.11.1.4ColumncxMcVoxGrpIdOpeNbPollread-onlyoptionalDetermines the maximum number of remote voice stations in an Extension Group that the local voice station polls with a single call request. Note: This object i…
1.3.6.1.4.1.495.2.1.1.2.12TablecxMcVoxGrpDefAdmTablenot-accessiblemandatoryPlanned GroupID definition table.
1.3.6.1.4.1.495.2.1.1.2.12.1RowcxMcVoxGrpDefAdmEntrynot-accessiblemandatoryPlanned GroupID row definition.
1.3.6.1.4.1.495.2.1.1.2.12.1.1ColumncxMcVoxGrpDefAdmIndexread-onlymandatoryDisplays the index number of the administrative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.12.1.2ColumncxMcVoxGrpDefAdmPriorityread-onlymandatoryDisplays the polling priority level of the administrative Path ID. When the user places a call by entering the Group ID, all Path IDs that you include in the g…
1.3.6.1.4.1.495.2.1.1.2.12.1.3ColumncxMcVoxGrpDefAdmRowStatusread-writemandatoryDetermines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be…
1.3.6.1.4.1.495.2.1.1.2.12.1.4ColumncxMcVoxGrpDefAdmPathIdread-writedeprecatedDetermines the Path ID you want to include in the administrative Group ID. When you include a Path ID in the Group ID, the software automatically assigns a pol…
1.3.6.1.4.1.495.2.1.1.2.12.1.5ColumncxMcVoxGrpDefAdmRmtExtread-writemandatoryDetermines the Remote Extension that you want to include in the Group ID. When you include a Remote Extension in the Group ID, the software automatically assig…
1.3.6.1.4.1.495.2.1.1.2.13TablecxMcVoxGrpDefOpeTablenot-accessiblemandatoryActive GroupID definition table.
1.3.6.1.4.1.495.2.1.1.2.13.1RowcxMcVoxGrpDefOpeEntrynot-accessiblemandatoryActive GroupID row definition.
1.3.6.1.4.1.495.2.1.1.2.13.1.1ColumncxMcVoxGrpDefOpeIndexread-onlymandatoryDisplays the index number of the operative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.13.1.2ColumncxMcVoxGrpDefOpePriorityread-onlymandatoryDisplays the polling priority level of the operative Path ID. When the user places a call by entering the Group ID, all Path IDs that you include in the group …
1.3.6.1.4.1.495.2.1.1.2.13.1.3ColumncxMcVoxGrpDefOpePathIdread-onlydeprecatedDisplays the Path ID included in the operative Group ID. When you include a Path ID in the Group ID, the software automatically assigns a polling priority to i…
1.3.6.1.4.1.495.2.1.1.2.13.1.4ColumncxMcVoxGrpDefOpeRmtExtread-onlymandatoryDetermines the Remote Extension that you want to include in the Group ID. When you include a Remote Extension in the Group ID, the software automatically assig…
1.3.6.1.4.1.495.2.1.1.2.14TablecxMcVoxAdmPinTablenot-accessiblemandatoryPersonal identification number Table.
1.3.6.1.4.1.495.2.1.1.2.14.1RowcxMcVoxAdmPinEntrynot-accessiblemandatoryPersonal identification number row definition.
1.3.6.1.4.1.495.2.1.1.2.14.1.1ColumncxMcVoxAdmPinIndexread-onlymandatoryDisplays the index number of the Personal Identification Number (PIN). You cannot modify this object. Range of Values: 1 to 256 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.14.1.2ColumncxMcVoxAdmPinCoderead-writemandatoryDetermines the Personal Identification Number (PIN) that is validated by the local voice station prior to a call being established. The local voice station ver…
1.3.6.1.4.1.495.2.1.1.2.14.1.3ColumncxMcVoxAdmPinRowStatusread-writemandatoryDetermines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be…
1.3.6.1.4.1.495.2.1.1.2.15TablecxMcVoxOpePinTablenot-accessiblemandatoryPersonal identification number Table.
1.3.6.1.4.1.495.2.1.1.2.15.1RowcxMcVoxOpePinEntrynot-accessiblemandatoryPersonal identification number row definition.
1.3.6.1.4.1.495.2.1.1.2.15.1.1ColumncxMcVoxOpePinIndexread-onlymandatoryDisplays the index number of the Personal identification Number (PIN). You cannot modify this object. Range of Values: 1 to 256. Default Value: none
1.3.6.1.4.1.495.2.1.1.2.15.1.2ColumncxMcVoxOpePinCoderead-onlymandatoryDisplays the Personal Identification Number (PIN) that is validated by the local voice station prior to a call being established. The local voice station verif…
1.3.6.1.4.1.495.2.1.1.2.16TablecxMcVoxAdmLclZoneTablenot-accessiblemandatoryLocal Zone Codes Table.
1.3.6.1.4.1.495.2.1.1.2.16.1RowcxMcVoxAdmLclZoneEntrynot-accessiblemandatoryLocal Zones codes row definition.
1.3.6.1.4.1.495.2.1.1.2.16.1.1ColumncxMcVoxAdmLclZoneIndexread-onlymandatoryDisplays the index number of the administrative local zone code. Range of Values: 1 to 128. Default Value: none
1.3.6.1.4.1.495.2.1.1.2.16.1.2ColumncxMcVoxAdmLclZoneCoderead-writemandatoryDetermines the number of the administrative local zone code which will serve in the verification of the phone number to be dialed depending on where the remote…
1.3.6.1.4.1.495.2.1.1.2.16.1.3ColumncxMcVoxAdmLclZoneLngread-onlymandatoryDetermines the length (in digits) of the administrative local zone code. Range of Values: 1 to 4 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.16.1.4ColumncxMcVoxAdmLclZoneRowStatusread-writemandatoryDetermines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be…
1.3.6.1.4.1.495.2.1.1.2.17TablecxMcVoxOpeLclZoneTablenot-accessiblemandatoryLocal Zones Codes Table.
1.3.6.1.4.1.495.2.1.1.2.17.1RowcxMcVoxOpeLclZoneEntrynot-accessiblemandatoryLocal Zones codes row definition.
1.3.6.1.4.1.495.2.1.1.2.17.1.1ColumncxMcVoxOpeLclZoneIndexread-onlymandatoryDisplays the index number of the operational local zone code. Range of Values: 1 to 128. Default Value: none
1.3.6.1.4.1.495.2.1.1.2.17.1.2ColumncxMcVoxOpeLclZoneCoderead-onlymandatoryDisplays the number of the operational local zone code which will serve in the verification of the phone number to be dialed depending on where the remote CX10…
1.3.6.1.4.1.495.2.1.1.2.17.1.3ColumncxMcVoxOpeLclZoneLngread-onlymandatoryDisplays the length (in digits) of the operational local zone code. You cannot modify this object. If you want to change the length you must change the setting…
1.3.6.1.4.1.495.2.1.1.2.18NodecxMcVoxAdmRTC
1.3.6.1.4.1.495.2.1.1.2.18.1ScalarcxMcVoxAdmRTCCountryread-writedeprecatedThe CX900 does not currently support this object. Determines the number of the administrative local country code which will serve in the verification of the ph…
1.3.6.1.4.1.495.2.1.1.2.18.2ScalarcxMcVoxAdmRTCCountryLngread-writedeprecatedThe CX900 does not currently support this object. Determines the length (in digits) of the administrative local country code. Range of Values: 1 to 4 Default V…
1.3.6.1.4.1.495.2.1.1.2.18.3ScalarcxMcVoxAdmRTCNonLclCountryread-writedeprecatedThe CX900 does not currently support this object. Determines the number of the administrative local country code which will be inserted in front of the Country…
1.3.6.1.4.1.495.2.1.1.2.18.4ScalarcxMcVoxAdmRTCNonLclCountryLngread-writedeprecatedThe CX900 does not currently support this object. Determines the length (in digits) of the administrative non local country code. Range of Values: 1 to 4. Defa…
1.3.6.1.4.1.495.2.1.1.2.18.5ScalarcxMcVoxAdmRTCArearead-writedeprecatedThe CX900 does not currently support this object. Determines the number of the administrative local area code which will serve in the verification of the phone…
1.3.6.1.4.1.495.2.1.1.2.18.6ScalarcxMcVoxAdmRTCAreaLngread-writedeprecatedThe CX900 does not currently support this object. Determines the length (in digits) of the administrative local area code. Range of Values: 1 to 4 Default Valu…
1.3.6.1.4.1.495.2.1.1.2.18.7ScalarcxMcVoxAdmRTCNonLclArearead-writedeprecatedThe CX900 does not currently support this object. Determines the number of the administrative local area code which will be inserted in front of the Area Code …
1.3.6.1.4.1.495.2.1.1.2.18.8ScalarcxMcVoxAdmRTCNonLclAreaLngread-writedeprecatedThe CX900 does not currently support this object. Determines the length (in digits) of the administrative non local area code. Range of Values: 1 to 4. Default…
1.3.6.1.4.1.495.2.1.1.2.18.9ScalarcxMcVoxAdmRTCNonLclZoneread-writedeprecatedThe CX900 does not currently support this object. Determines the number of the administrative local zone code which will be inserted in front of the Zone Code …
1.3.6.1.4.1.495.2.1.1.2.18.10ScalarcxMcVoxAdmRTCNonLclZoneLngread-writedeprecatedThe CX900 does not currently support this object. Determines the length (in digits) of the administrative non local zone code. Range of Values: 1 to 4 Default …
1.3.6.1.4.1.495.2.1.1.2.19NodecxMcVoxOpeRTC
1.3.6.1.4.1.495.2.1.1.2.19.1ScalarcxMcVoxOpeRTCCountryread-onlydeprecatedThe CX900 does not currently support this object. Displays the number of the operative local country code which will serve in the verification of the phone num…
1.3.6.1.4.1.495.2.1.1.2.19.2ScalarcxMcVoxOpeRTCCountryLngread-onlydeprecatedThe CX900 does not currently support this object. Displays the length (in digits) of the operative local country code. Range of Values: 1 to 4. Default Value: …
1.3.6.1.4.1.495.2.1.1.2.19.3ScalarcxMcVoxOpeRTCNonLclCountryread-onlydeprecatedThe CX900 does not currently support this object. Displays the number of the operative local country code which will be inserted in front of the Country Code i…
1.3.6.1.4.1.495.2.1.1.2.19.4ScalarcxMcVoxOpeRTCNonLclCountryLngread-onlydeprecatedThe CX900 does not currently support this object. Displays the length (in digits) of the operative non local country code. Range of Values: 1 to 4. Default Val…
1.3.6.1.4.1.495.2.1.1.2.19.5ScalarcxMcVoxOpeRTCArearead-onlydeprecatedThe CX900 does not currently support this object. Displays the number of the operative local area code which will serve in the verification of the phone number…
1.3.6.1.4.1.495.2.1.1.2.19.6ScalarcxMcVoxOpeRTCAreaLngread-onlydeprecatedThe CX900 does not currently support this object. Displays the length (in digits) of the operative local area code. Range of Values: 1 to 4. Default Value: none
1.3.6.1.4.1.495.2.1.1.2.19.7ScalarcxMcVoxOpeRTCNonLclArearead-onlydeprecatedThe CX900 does not currently support this object. Displays the number of the operative local area code which will be inserted in front of the Area Code if the …
1.3.6.1.4.1.495.2.1.1.2.19.8ScalarcxMcVoxOpeRTCNonLclAreaLngread-onlydeprecatedThe CX900 does not currently support this object. Displays the length (in digits) of the operative non local area code. Range of Values: 1 to 4 Default Value: …
1.3.6.1.4.1.495.2.1.1.2.19.9ScalarcxMcVoxOpeRTCNonLclZoneread-onlydeprecatedThe CX900 does not currently support this object. Displays the number of the operative local zone code which will be inserted in front of the Zone Code if the …
1.3.6.1.4.1.495.2.1.1.2.19.10ScalarcxMcVoxOpeRTCNonLclZoneLngread-onlydeprecatedThe CX900 does not currently support this object. Displays the length (in digits) of the operative non local zone code. Range of Values: 1 to 4 Default Value: …
1.3.6.1.4.1.495.2.1.1.2.20NodecxMcVoxDriverAdmPriv
1.3.6.1.4.1.495.2.1.1.2.20.1TablecxMcVoxAdmPortPrivTablenot-accessiblemandatoryVoice station planned Table.
1.3.6.1.4.1.495.2.1.1.2.20.1.1RowcxMcVoxAdmPortPrivEntrynot-accessiblemandatoryVoice station planned row definition.
1.3.6.1.4.1.495.2.1.1.2.20.1.1.1ColumncxMcVoxAdmCardUsedread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object Range of Values: CX900: 1 to 6 CX1000: 1 to 4 Default: none
1.3.6.1.4.1.495.2.1.1.2.20.1.1.2ColumncxMcVoxAdmPortUsedread-onlymandatoryDisplays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable …
1.3.6.1.4.1.495.2.1.1.2.20.1.1.3ColumncxMcVoxAdmRingTimeOnread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.4ColumncxMcVoxAdmRingTimeOff1read-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 4000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.5ColumncxMcVoxAdmRingTimeOff2read-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.6ColumncxMcVoxAdmEchoCancelLevelread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 100
1.3.6.1.4.1.495.2.1.1.2.20.1.1.7ColumncxMcVoxAdmToneDelayAfterCnctread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.8ColumncxMcVoxAdmToneDelayAfterFlashread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 400
1.3.6.1.4.1.495.2.1.1.2.20.1.1.9ColumncxMcVoxAdmToneOffsetTxGainread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.10ColumncxMcVoxAdmVoiceOffsetTxGainread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.11ColumncxMcVoxAdmAc15InterDigitread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 800
1.3.6.1.4.1.495.2.1.1.2.20.1.1.12ColumncxMcVoxAdmMfToneTholdread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 60
1.3.6.1.4.1.495.2.1.1.2.20.1.1.13ColumncxMcVoxAdmPulseTminread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 15
1.3.6.1.4.1.495.2.1.1.2.20.1.1.14ColumncxMcVoxAdmPulseTmaxread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 125
1.3.6.1.4.1.495.2.1.1.2.20.1.1.15ColumncxMcVoxAdmPulseInterDigitread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 275
1.3.6.1.4.1.495.2.1.1.2.20.1.1.16ColumncxMcVoxAdmDtmfGuardread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 40
1.3.6.1.4.1.495.2.1.1.2.20.1.1.17ColumncxMcVoxAdmDtmfOpeLevelread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: minus-25 (1) minus-28 (2) minus-31 (3) minus-34 (4) Default V…
1.3.6.1.4.1.495.2.1.1.2.20.1.1.18ColumncxMcVoxAdmDtmfTxTimeOnread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 500 Default Value: 75
1.3.6.1.4.1.495.2.1.1.2.20.1.1.19ColumncxMcVoxAdmDtmfTxTimeOffread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 500 Default Value: 75
1.3.6.1.4.1.495.2.1.1.2.20.1.1.20ColumncxMcVoxAdmFlashTminread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 200
1.3.6.1.4.1.495.2.1.1.2.20.1.1.21ColumncxMcVoxAdmFlashTmaxread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 800
1.3.6.1.4.1.495.2.1.1.2.20.1.1.22ColumncxMcVoxAdmFlashTgenread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.20.1.1.23ColumncxMcVoxAdmAfterToneSilencesread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 64
1.3.6.1.4.1.495.2.1.1.2.20.1.1.24ColumncxMcVoxAdmFaxTxGainread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.25ColumncxMcVoxAdmFaxRxGainread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.26ColumncxMcVoxAdmFaxHdlcFlagsread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 2
1.3.6.1.4.1.495.2.1.1.2.20.1.1.27ColumncxMcVoxAdmFaxPreambleDurationread-writedeprecatedWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.28ColumncxMcVoxAdmFaxPreambleDelayread-writedeprecatedWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
1.3.6.1.4.1.495.2.1.1.2.20.1.1.29ColumncxMcVoxAdmFaxCedToneDurationread-writedeprecatedWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.20.1.1.30ColumncxMcVoxAdmFaxInterProtoGapread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 75
1.3.6.1.4.1.495.2.1.1.2.20.1.1.31ColumncxMcVoxAdmFaxTimerDetectSyncread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 7500
1.3.6.1.4.1.495.2.1.1.2.20.1.1.32ColumncxMcVoxAdmFaxTimerWaitIdread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 40000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.33ColumncxMcVoxAdmFaxMinPreambleDurread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.34ColumncxMcVoxAdmFaxMaxPreambleDurread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1200
1.3.6.1.4.1.495.2.1.1.2.20.1.1.35ColumncxMcVoxAdmFaxMinPreambleDlyread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 400
1.3.6.1.4.1.495.2.1.1.2.20.1.1.36ColumncxMcVoxAdmFaxMaxPreambleDlyread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
1.3.6.1.4.1.495.2.1.1.2.20.1.1.37ColumncxMcVoxAdmFaxCedToneDetectionread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.20.1.1.38ColumncxMcVoxAdmFaxCedMinToneDurread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 2600
1.3.6.1.4.1.495.2.1.1.2.20.1.1.39ColumncxMcVoxAdmFaxCedMaxToneDurread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000
1.3.6.1.4.1.495.2.1.1.2.20.1.1.40ColumncxMcVoxAdmFaxMaxHdlcFlagsread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 32
1.3.6.1.4.1.495.2.1.1.2.21NodecxMcVoxDriverOpePriv
1.3.6.1.4.1.495.2.1.1.2.21.1TablecxMcVoxOpePortPrivTablenot-accessiblemandatoryVoice station planned Table.
1.3.6.1.4.1.495.2.1.1.2.21.1.1RowcxMcVoxOpePortPrivEntrynot-accessiblemandatoryVoice station planned row definition.
1.3.6.1.4.1.495.2.1.1.2.21.1.1.1ColumncxMcVoxOpeCardUsedread-onlymandatoryDisplays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none
1.3.6.1.4.1.495.2.1.1.2.21.1.1.2ColumncxMcVoxOpePortUsedread-onlymandatoryDisplays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000…
1.3.6.1.4.1.495.2.1.1.2.21.1.1.3ColumncxMcVoxOpeRingTimeOnread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.4ColumncxMcVoxOpeRingTimeOff1read-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 4000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.5ColumncxMcVoxOpeRingTimeOff2read-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.6ColumncxMcVoxOpeEchoCancelLevelread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 100
1.3.6.1.4.1.495.2.1.1.2.21.1.1.7ColumncxMcVoxOpeToneDelayAfterCnctread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.8ColumncxMcVoxOpeToneDelayAfterFlashread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 400
1.3.6.1.4.1.495.2.1.1.2.21.1.1.9ColumncxMcVoxOpeToneOffsetTxGainread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.10ColumncxMcVoxOpeVoiceOffsetTxGainread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.11ColumncxMcVoxOpeAc15InterDigitread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 800
1.3.6.1.4.1.495.2.1.1.2.21.1.1.12ColumncxMcVoxOpeMfToneTholdread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 60
1.3.6.1.4.1.495.2.1.1.2.21.1.1.13ColumncxMcVoxOpePulseTminread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 15
1.3.6.1.4.1.495.2.1.1.2.21.1.1.14ColumncxMcVoxOpePulseTmaxread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 125
1.3.6.1.4.1.495.2.1.1.2.21.1.1.15ColumncxMcVoxOpePulseInterDigitread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 275
1.3.6.1.4.1.495.2.1.1.2.21.1.1.16ColumncxMcVoxOpeDtmfGuardread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 40
1.3.6.1.4.1.495.2.1.1.2.21.1.1.17ColumncxMcVoxOpeDtmfOpeLevelread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: minus-25 (1) minus-28 (2) minus-31 (3) minus-34 (4) Default V…
1.3.6.1.4.1.495.2.1.1.2.21.1.1.18ColumncxMcVoxOpeDtmfTxTimeOnread-onlymandatoryThis object is read-only. Range of Values: 0 to 500
1.3.6.1.4.1.495.2.1.1.2.21.1.1.19ColumncxMcVoxOpeDtmfTxTimeOffread-onlymandatoryThis object is read-only. Range of Values: 0 to 500
1.3.6.1.4.1.495.2.1.1.2.21.1.1.20ColumncxMcVoxOpeFlashTminread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 200
1.3.6.1.4.1.495.2.1.1.2.21.1.1.21ColumncxMcVoxOpeFlashTmaxread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 800
1.3.6.1.4.1.495.2.1.1.2.21.1.1.22ColumncxMcVoxOpeFlashTgenread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.21.1.1.23ColumncxMcVoxOpeAfterToneSilencesread-onlymandatoryThis object is read-only. Range of Values: 0 to 127
1.3.6.1.4.1.495.2.1.1.2.21.1.1.24ColumncxMcVoxOpeFaxTxGainread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.25ColumncxMcVoxOpeFaxRxGainread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.26ColumncxMcVoxOpeFaxHdlcFlagsread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 2
1.3.6.1.4.1.495.2.1.1.2.21.1.1.27ColumncxMcVoxOpeFaxPreambleDurationread-writedeprecatedWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.28ColumncxMcVoxOpeFaxPreambleDelayread-writedeprecatedWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
1.3.6.1.4.1.495.2.1.1.2.21.1.1.29ColumncxMcVoxOpeFaxCedToneDurationread-writedeprecatedWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.21.1.1.30ColumncxMcVoxOpeFaxInterProtoGapread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 75
1.3.6.1.4.1.495.2.1.1.2.21.1.1.31ColumncxMcVoxOpeFaxTimerDetectSyncread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 7500
1.3.6.1.4.1.495.2.1.1.2.21.1.1.32ColumncxMcVoxOpeFaxTimerWaitIdread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 40000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.33ColumncxMcVoxOpeFaxMinPreambleDurread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.34ColumncxMcVoxOpeFaxMaxPreambleDurread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1200
1.3.6.1.4.1.495.2.1.1.2.21.1.1.35ColumncxMcVoxOpeFaxMinPreambleDlyread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 400
1.3.6.1.4.1.495.2.1.1.2.21.1.1.36ColumncxMcVoxOpeFaxMaxPreambleDlyread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
1.3.6.1.4.1.495.2.1.1.2.21.1.1.37ColumncxMcVoxOpeFaxCedToneDetectionread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500
1.3.6.1.4.1.495.2.1.1.2.21.1.1.38ColumncxMcVoxOpeFaxCedMinToneDurread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 2600
1.3.6.1.4.1.495.2.1.1.2.21.1.1.39ColumncxMcVoxOpeFaxCedMaxToneDurread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000
1.3.6.1.4.1.495.2.1.1.2.21.1.1.40ColumncxMcVoxOpeFaxMaxHdlcFlagsread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 32
1.3.6.1.4.1.495.2.1.1.2.23NodecxMcVoxTimerOpePriv
1.3.6.1.4.1.495.2.1.1.2.23.1TablecxMcVoxOpeTimerPrivTablenot-accessiblemandatoryVoice station planned Table.
1.3.6.1.4.1.495.2.1.1.2.23.1.1RowcxMcVoxOpeTimerPrivEntrynot-accessiblemandatoryVoice station planned row definition.
1.3.6.1.4.1.495.2.1.1.2.23.1.1.1ColumncxMcVoxOpeInterfaceTyperead-onlymandatoryDisplays the interface type of the voice I/O port. You cannot modify this object Options: em (1) fxs (2) fxo (3) Default: none
1.3.6.1.4.1.495.2.1.1.2.23.1.1.2ColumncxMcVoxOpeTimeSeizeInread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 50
1.3.6.1.4.1.495.2.1.1.2.23.1.1.3ColumncxMcVoxOpeTimeWaitDialOutread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 100
1.3.6.1.4.1.495.2.1.1.2.23.1.1.4ColumncxMcVoxOpeTimeWaitDialInread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 200
1.3.6.1.4.1.495.2.1.1.2.23.1.1.5ColumncxMcVoxOpeTimeDialOutread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 50
1.3.6.1.4.1.495.2.1.1.2.23.1.1.6ColumncxMcVoxOpeTimeDialInread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 30
1.3.6.1.4.1.495.2.1.1.2.23.1.1.7ColumncxMcVoxOpeTimeSiOffread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 300
1.3.6.1.4.1.495.2.1.1.2.23.1.1.8ColumncxMcVoxOpeTimeProceedread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 30000
1.3.6.1.4.1.495.2.1.1.2.23.1.1.9ColumncxMcVoxOpeTimeAnswerread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 60000
1.3.6.1.4.1.495.2.1.1.2.23.1.1.10ColumncxMcVoxOpeTimeBeforeToneOffread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000
1.3.6.1.4.1.495.2.1.1.2.23.1.1.11ColumncxMcVoxOpeTimeWinkStartInread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 220
1.3.6.1.4.1.495.2.1.1.2.23.1.1.12ColumncxMcVoxOpeTimeWinkStartOutread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 125
1.3.6.1.4.1.495.2.1.1.2.23.1.1.13ColumncxMcVoxOpeTimeWinkMinread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 140
1.3.6.1.4.1.495.2.1.1.2.23.1.1.14ColumncxMcVoxOpeTimeWinkMaxread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 290
1.3.6.1.4.1.495.2.1.1.2.23.1.1.15ColumncxMcVoxOpeTimeSeizeread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 250
1.3.6.1.4.1.495.2.1.1.2.23.1.1.16ColumncxMcVoxOpeTimeDialread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 210
1.3.6.1.4.1.495.2.1.1.2.23.1.1.17ColumncxMcVoxOpeTimeOffInread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900
1.3.6.1.4.1.495.2.1.1.2.23.1.1.18ColumncxMcVoxOpeTimeSiOnread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 100
1.3.6.1.4.1.495.2.1.1.2.23.1.1.19ColumncxMcVoxOpeTimeOffOutread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 150
1.3.6.1.4.1.495.2.1.1.2.23.1.1.20ColumncxMcVoxOpeTimeDiscInread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 250
1.3.6.1.4.1.495.2.1.1.2.23.1.1.21ColumncxMcVoxOpeTimeDiscOutread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 650
1.3.6.1.4.1.495.2.1.1.2.23.1.1.22ColumncxMcVoxOpeTimeToneOutread-writemandatoryWARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 15000
1.3.6.1.4.1.495.2.1.1.2.24TablecxMcVoxDiagTablenot-accessiblemandatoryVoice station diagnostics and events Table.
1.3.6.1.4.1.495.2.1.1.2.24.1RowcxMcVoxDiagEntrynot-accessiblemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.1ColumncxMcVoxDiagCardIndexread-onlymandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.2ColumncxMcVoxDiagPortIndexread-onlymandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.3ColumncxMcVoxDiagScvEventsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.4ColumncxMcVoxDiagGsdEventsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.5ColumncxMcVoxDiagToneInEventsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.6ColumncxMcVoxDiagToneOutEventsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.7ColumncxMcVoxDiagFaxInEventsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.8ColumncxMcVoxDiagFaxOutEventsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.9ColumncxMcVoxDiagGlmEventsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.10ColumncxMcVoxDiagIbvDiagsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.11ColumncxMcVoxDiagPcvDiagsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.12ColumncxMcVoxDiagGcvDiagsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.13ColumncxMcVoxDiagFaxDiagsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.14ColumncxMcVoxDiagLseDiagsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.15ColumncxMcVoxDiagScvDiagsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.24.1.16ColumncxMcVoxDiagGlmDiagsread-writemandatory
1.3.6.1.4.1.495.2.1.1.2.25NodecxMcVoxDownload
1.3.6.1.4.1.495.2.1.1.2.26TablecxMcVoxLclExtAdmTablenot-accessiblemandatoryPlanned Local Extensions table.
1.3.6.1.4.1.495.2.1.1.2.26.1RowcxMcVoxLclExtAdmEntrynot-accessiblemandatoryPlanned Local Extensions row definition.
1.3.6.1.4.1.495.2.1.1.2.26.1.1ColumncxMcVoxLclExtAdmIndexread-onlymandatoryDisplays the index number of the Remote Extension. You cannot modify this object. Range of Values: 1 to 64 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.26.1.2ColumncxMcVoxLclExtAdmRowStatusread-writemandatoryDetermines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values are disabled and the row is deleted …
1.3.6.1.4.1.495.2.1.1.2.26.1.3ColumncxMcVoxLclExtAdmExtread-writemandatoryDetermines the numeric dialing code to be dialed by remote located parties to access the local telephone or fax machine. Range of Values: 1 to 5 numeric digits…
1.3.6.1.4.1.495.2.1.1.2.26.1.4ColumncxMcVoxLclExtAdmHuntChnlread-writemandatoryDefines the local voice channels to be polled (hunted) during call establishment with the Local Extension (specified by object cxMcVoxLclExtAdmExt). This value…
1.3.6.1.4.1.495.2.1.1.2.27TablecxMcVoxLclExtOpeTablenot-accessiblemandatoryActive Local Extensions table.
1.3.6.1.4.1.495.2.1.1.2.27.1RowcxMcVoxLclExtOpeEntrynot-accessiblemandatoryActive Local Extensions row definition.
1.3.6.1.4.1.495.2.1.1.2.27.1.1ColumncxMcVoxLclExtOpeIndexread-onlymandatoryDisplays the index number of the Remote Extension. You cannot modify this object. Range of Values: 1 to 64 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.27.1.2ColumncxMcVoxLclExtOpeExtread-onlymandatoryDetermines the numeric dialing code to be dialed by remote located parties to access the local telephone or fax machine. Range of Values: 1 to 5 numeric digits…
1.3.6.1.4.1.495.2.1.1.2.27.1.3ColumncxMcVoxLclExtOpeHuntChnlread-onlymandatoryDefines the local voice channels to be polled (hunted) during call establishment with the Local Extension (specified by object cxMcVoxLclExtAdmExt). This value…
1.3.6.1.4.1.495.2.1.1.2.28NodecxMcVoxRegenOpe
1.3.6.1.4.1.495.2.1.1.2.28.1ScalarcxMcVoxRegenOpeExtread-writemandatoryThe RegenOpeExt is used to specify if the local extension tones are to be regenerated.
1.3.6.1.4.1.495.2.1.1.2.28.2ScalarcxMcVoxRegenOpeGidread-writemandatoryThe RegenOpeGid is used to specify if the group ids tones are to be regenerated.
1.3.6.1.4.1.495.2.1.1.2.28.3ScalarcxMcVoxRegenOpeNbDigitsread-writemandatoryThe number of digits to be regenerated.
1.3.6.1.4.1.495.2.1.1.2.28.4ScalarcxMcVoxRegenOpeExtBitMaskread-writemandatoryThis object is a bitmap that selects up to cxMcVoxRegenOpeNbDigits, which can be set up to 8 digits, corresponding to a bit that is set. The default value corr…
1.3.6.1.4.1.495.2.1.1.2.29NodecxMcVoxTranslOpe
1.3.6.1.4.1.495.2.1.1.2.29.1ScalarcxMcVoxTranslOpeCntryCodeEnableread-writemandatoryThis specifies whether to translate the local country code.
1.3.6.1.4.1.495.2.1.1.2.29.2ScalarcxMcVoxTranslOpeCntryCoderead-writemandatoryDisplays the number of the operational local country code which will serve in the verification of the phone number to be dialed depending on where the remote s…
1.3.6.1.4.1.495.2.1.1.2.29.3ScalarcxMcVoxTranslOpeCntryCodeLngread-onlymandatoryDisplays the length (in digits) of the operational local country code. Range of Values: 1 to 4. Default Value: none
1.3.6.1.4.1.495.2.1.1.2.29.4ScalarcxMcVoxTranslOpeCCPrefixread-writemandatoryDisplays the number of the operational local country code which will be inserted in front of the Country Code if the latter does not correspond to the local co…
1.3.6.1.4.1.495.2.1.1.2.29.5ScalarcxMcVoxTranslOpeCCPrefixLngread-onlymandatoryDisplays the length (in digits) of the operational non local country code. Range of Values: 1 to 4. Default Value: none
1.3.6.1.4.1.495.2.1.1.2.29.6ScalarcxMcVoxTranslOpeAreaCodeEnableread-writemandatoryThis specifies whether to translate the local area code.
1.3.6.1.4.1.495.2.1.1.2.29.7ScalarcxMcVoxTranslOpeAreaCoderead-writemandatoryDisplays the number of the operational local area code which will serve in the verification of the phone number to be dialed depending on where the remote site…
1.3.6.1.4.1.495.2.1.1.2.29.8ScalarcxMcVoxTranslOpeAreaCodeLngread-onlymandatoryDisplays the length (in digits) of the operational local area code. Range of Values: 1 to 4. Default Value: none
1.3.6.1.4.1.495.2.1.1.2.29.9ScalarcxMcVoxTranslOpeACPrefixread-writemandatoryDisplays the number of the operational local area code which will be inserted in front of the Area Code if the latter does not correspond to the local country …
1.3.6.1.4.1.495.2.1.1.2.29.10ScalarcxMcVoxTranslOpeACPrefixLngread-onlymandatoryDisplays the length (in digits) of the operational non local area code. Range of Values: 1 to 4 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.29.11ScalarcxMcVoxTranslOpeZoneCodeEnableread-writemandatoryThis specifies whether to translate the local zone code.
1.3.6.1.4.1.495.2.1.1.2.29.12ScalarcxMcVoxTranslOpeZCPrefixread-writemandatoryDisplays the number of the operational local zone code which will be inserted in front of the Zone Code if the latter does not correspond to the local country …
1.3.6.1.4.1.495.2.1.1.2.29.13ScalarcxMcVoxTranslOpeZCPrefixLngread-onlymandatoryDisplays the length (in digits) of the operational non local zone code. Range of Values: 1 to 4 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.30TablecxMcVoxHistoryTablenot-accessiblemandatoryOnLine/OffLine history table for incoming/outgoing calls.
1.3.6.1.4.1.495.2.1.1.2.30.1RowcxMcVoxHistoryEntrynot-accessiblemandatoryOnline/Offline history row definition.
1.3.6.1.4.1.495.2.1.1.2.30.1.1ColumncxMcVoxHistoryIndexread-onlymandatoryThe index number of the history log.
1.3.6.1.4.1.495.2.1.1.2.30.1.2ColumncxMcVoxHistoryLclCardNumberread-onlymandatoryDisplays the voice I/O card slot displacement from the CPU card slot. As an example on the CX1000, card number 1 is directly behind the CPU card and card numbe…
1.3.6.1.4.1.495.2.1.1.2.30.1.3ColumncxMcVoxHistoryLclPortNumberread-onlymandatoryDisplays the number of the voice I/O port. You cannot modify this object. Range of Values: 1 to 15 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.30.1.4ColumncxMcVoxHistoryRmtCardNumberread-onlymandatoryDisplays the remote voice I/O card slot displacement from the CPU card slot. As an example on the CX1000, card number 1 is directly behind th You cannot modify…
1.3.6.1.4.1.495.2.1.1.2.30.1.5ColumncxMcVoxHistoryRmtPortNumberread-onlymandatoryDisplays the number of the voice I/O port that was reached at the remote location. You cannot modify this object. Range of Values: 1 to 15 Default Value: none
1.3.6.1.4.1.495.2.1.1.2.30.1.6ColumncxMcVoxHistoryTimeStampOnLineread-onlymandatoryDisplays the time stamp of the last on-line event. An on-line event is any incoming or outgoing call that is started. The time stamp indicates the number of se…
1.3.6.1.4.1.495.2.1.1.2.30.1.7ColumncxMcVoxHistoryTimeStampOffLineread-onlymandatoryDisplays the time stamp of the last off-line event. An off-line event is any incoming or outgoing call that the voice station terminates. The time stamp indica…
1.3.6.1.4.1.495.2.1.1.2.30.1.8ColumncxMcVoxHistoryLnkStateread-onlymandatoryDisplays the status of the link to the remote user. When the call is successful the status is either 'Incoming' or 'Outgoing'. Else the error type is displayed…
1.3.6.1.4.1.495.2.1.1.2.30.1.9ColumncxMcVoxHistoryPinread-onlymandatoryDisplays the Personal Identification Number (PIN) that is validated against the local voice station card PIN number table. Range of Values: 2 to 8 numeric digi…
1.3.6.1.4.1.495.2.1.1.2.30.1.10ColumncxMcVoxHistoryExtensionOrGrpIdread-onlymandatoryDisplays the extension or group ID the remote user has dialed to reach the local user. This object is irrelevant for outgoing calls. You cannot modify this obj…
1.3.6.1.4.1.495.2.1.1.2.30.1.11ColumncxMcVoxHistoryPhoneNumberread-onlymandatoryFor outgoing calls, this object displays the complete phone number (including any voice mail digits) the user entered to reach the remote user. This can includ…