CXTokenBus-MIB
54 objects
No module-level DESCRIPTION found.
Imported Objects
| CXProduct-SMI | Alias cxTokenBus SapIndex |
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.495.2.1.5.9.1 | TabletbSapTable | not-accessible | mandatory | A table containing configuration information about each LLC service access point. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1 | RowtbSapEntry | not-accessible | mandatory | The parameters for a particular frame relay module service access point. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.1 | ColumntbSapNumber | read-only | mandatory | This object serves to identify the service access point by a numerical value. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.2 | ColumntbSapRowStatus | read-write | mandatory | Indicates whether the particular service access point is configured within the MIB. Service access point entries (rows) may be created by setting this object v… |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.3 | ColumntbSapAlias | read-write | mandatory | Identifies the service access point by a textual name. Names are unique per service access point. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.4 | ColumntbSapCompanionAlias | read-write | mandatory | Identifies the remote service access point that will communicate with this service access point by a textual name. Names are unique per service access point. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.5 | ColumntbSapType | read-write | mandatory | This object serves to identify the service access point by type: 'lower' or 'upper'. In our case, only upper is relevent but this object is kept for uniformity… |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.6 | ColumntbSapStatGathering | read-write | mandatory | This object specifies if the SAP statistics will be updated. If disabled, the counter will always be zero. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.7 | ColumntbSapStatRxUnitDataFrames | read-only | mandatory | Indicates the number of data frames received from the upper layer which requested no acknowledgment from the destination token bus module. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.8 | ColumntbSapStatRxUnitDataOctets | read-only | mandatory | Indicates the number of data octets received from the upper layer which requested no acknowledgment from the destination token bus module. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.9 | ColumntbSapStatRxDataAckFrames | read-only | mandatory | Indicates the number of data frames received from the upper layer which requested an acknowledgment from the destination token bus module. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.10 | ColumntbSapStatRxDataAckOctets | read-only | mandatory | Indicates the number of data octets received from the upper layer which requested an acknowledgment from the destination token bus module. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.11 | ColumntbSapStatTxUnitDataFrames | read-only | mandatory | Indicates the number of data frames sent to the upper layer where the originating card did not request an acknowledgment. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.12 | ColumntbSapStatTxUnitDataOctets | read-only | mandatory | Indicates the number of data octets sent to the upper layer where the originating card did not request an acknowledgment. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.13 | ColumntbSapStatTxDataAckFrames | read-only | mandatory | Indicates the number of data frames sent to the upper layer where the originating card requested an acknowledgment. |
| 1.3.6.1.4.1.495.2.1.5.9.1.1.14 | ColumntbSapStatTxDataAckOctets | read-only | mandatory | Indicates the number of data octets sent to the upper layer where the originating card requested an acknowledgment. |
| 1.3.6.1.4.1.495.2.1.5.9.2 | NodetbDevice | |||
| 1.3.6.1.4.1.495.2.1.5.9.2.1 | ScalartbDevPollingInterval | read-write | mandatory | This determine how often the Token Bus Device will be polled for transmission completion and frame reception. This value is in millisecond. If this value is 0,… |
| 1.3.6.1.4.1.495.2.1.5.9.2.2 | ScalartbRxFrameDescriptors | read-write | mandatory | Number of frame descriptors allocated to the token bus device (MC68824) to perform the receive process. |
| 1.3.6.1.4.1.495.2.1.5.9.2.3 | ScalartbRxBufferDescriptors | read-write | mandatory | Number of buffer descriptors allocated to the token bus device (MC68824) to perform the receive process. |
| 1.3.6.1.4.1.495.2.1.5.9.2.4 | ScalartbTxFrameDescriptors | read-write | mandatory | Number of frame descriptors allocated to the token bus device (MC68824) to perform the transmission process. |
| 1.3.6.1.4.1.495.2.1.5.9.2.5 | ScalartbTxBufferDescriptors | read-write | mandatory | Number of buffer descriptors allocated to the token bus device (MC68824) to perform the transmission process. |
| 1.3.6.1.4.1.495.2.1.5.9.2.6 | ScalartbMaxFrameSizeClass6 | read-write | mandatory | Maximum frame size permit to be transmitted at the access class 6. This maximum must be enforced to guaranty the maximum token rotation time specified above. |
| 1.3.6.1.4.1.495.2.1.5.9.2.7 | ScalartbMaxFrameSizeClass4 | read-write | mandatory | Maximum frame size permit to be transmitted at the access class 4. |
| 1.3.6.1.4.1.495.2.1.5.9.2.8 | ScalartbMaxFrameSizeClass2 | read-write | mandatory | Maximum frame size permit to be transmitted at the access class 2. |
| 1.3.6.1.4.1.495.2.1.5.9.2.9 | ScalartbMaxFrameSizeClass0 | read-write | mandatory | Maximum frame size permit to be transmitted at the access class 0. |
| 1.3.6.1.4.1.495.2.1.5.9.2.10 | ScalartbHiPriorityTokenHoldTime | read-write | mandatory | Maximum time a station can hold the token to transmit frame at the highest priority (access class 6). The value to configure may be calculated with this formul… |
| 1.3.6.1.4.1.495.2.1.5.9.2.11 | ScalartbTargetRotationTimeClass4 | read-write | mandatory | This parameter defines the target rotation time for the access class 4. The value to configure may be calculated with this formula: tbTargetRotationTimeClass4=… |
| 1.3.6.1.4.1.495.2.1.5.9.2.12 | ScalartbTargetRotationTimeClass2 | read-write | mandatory | This parameter defines the target rotation time for the access class 2. The value to configure may be calculated with this formula: tbTargetRotationTimeClass2=… |
| 1.3.6.1.4.1.495.2.1.5.9.2.13 | ScalartbTargetRotationTimeClass0 | read-write | mandatory | This parameter defines the target rotation time for the access class 0. The value to configure may be calculated with this formula: tbTargetRotationTimeClass0=… |
| 1.3.6.1.4.1.495.2.1.5.9.2.14 | ScalartbTargetRotationForMaintenance | read-write | mandatory | This parameter defines the target rotation time for the ring maintenance. The value to configure may be calculated with this formula: tbTargetRotationorMainten… |
| 1.3.6.1.4.1.495.2.1.5.9.2.15 | ScalartbMaxInterSolicitCount | read-write | mandatory | This parameter defines the target rotation time for the ring maintenance. The value to configure may be calculated with this formula: tbTimeForMaintenance = (t… |
| 1.3.6.1.4.1.495.2.1.5.9.2.16 | ScalartbNonRwrMaxRetryLimit | read-write | mandatory | This parameter specifies how many times the MC68824 chip set will try to retransmit a request with no response (RWNR) frame on which it detected a transmission… |
| 1.3.6.1.4.1.495.2.1.5.9.2.17 | ScalartbRwrMaxRetryLimit | read-write | mandatory | This parameter specifies how many time the MC68824 chip set will try to retransmit a request with response (RWR) frame on which it detected a transmission fail… |
| 1.3.6.1.4.1.495.2.1.5.9.2.18 | ScalartbSlotTime | read-write | mandatory | This parameter specifies how much time the MC68824 chip set will wait for a response on a transmission a request with response (RWR) frame. This parameter must… |
| 1.3.6.1.4.1.495.2.1.5.9.2.19 | ScalartbTxNonRwrFailures | read-only | mandatory | Number of transmission failures related to the request with no response frames. |
| 1.3.6.1.4.1.495.2.1.5.9.2.20 | ScalartbTxRwrFailures | read-only | mandatory | Number of transmission failure related to the request with response frames. |
| 1.3.6.1.4.1.495.2.1.5.9.2.21 | ScalartbUnexpectedFrame6s | read-only | mandatory | This counter incrementes when the TBC hears an unexpected frame when expecting a response to a transmitted request with response frame. An unexpected frame in … |
| 1.3.6.1.4.1.495.2.1.5.9.2.22 | ScalartbUnexpectedFrame10s | read-only | mandatory | The TBC module incremented this counter when it executes the 'unexpected frame 10' transition the IEEE 802.4 access control machine (ACM). It occurs when the T… |
| 1.3.6.1.4.1.495.2.1.5.9.2.23 | ScalartbNbUnderruns | read-only | mandatory | This statistic represents the number of times the TBC detected a FIFO underrun during transmission. |
| 1.3.6.1.4.1.495.2.1.5.9.2.24 | ScalartbRxRetryRwrFrames | read-only | mandatory | Number of detected retransmitted request with response frame. This event mostly occurs when the RWR frame or its response is lost. |
| 1.3.6.1.4.1.495.2.1.5.9.2.25 | ScalartbRxNullLsduRwrFrames | read-only | mandatory | Number of received request with response frame which did not contain any LLC service data unit (LDSU). |
| 1.3.6.1.4.1.495.2.1.5.9.2.26 | ScalartbNbPassedTokens | read-only | mandatory | Number of time this station thinks it has sucessfully passed the token. It can be used to calculate the average token rotation time. |
| 1.3.6.1.4.1.495.2.1.5.9.2.27 | ScalartbNbHeardTokens | read-only | mandatory | Number of time this station heard a token where Destination Address (DA) or Source Address (SA) are not equal to This Station (TS) address. This number can be … |
| 1.3.6.1.4.1.495.2.1.5.9.2.28 | ScalartbNbNoSuccessor8Passes | read-only | mandatory | This statistic indicates the number of times this station has gone through the no successor 8 arc in the state machine. This happens when the TBC fails to pass… |
| 1.3.6.1.4.1.495.2.1.5.9.2.29 | ScalartbNbWhoFollowsFrames | read-only | mandatory | This statistic is the number of times this station has had to look for a new next station to pass the token to. This frame is sent as part of the TBC's effort … |
| 1.3.6.1.4.1.495.2.1.5.9.2.30 | ScalartbNbTokenPassFailures | read-only | mandatory | This statistic indicates the number of token pass failed transitions when pass state is equal to pass token. Upon failing to pass the token, the TBC tries to s… |
| 1.3.6.1.4.1.495.2.1.5.9.2.31 | ScalartbRxPeriodNonSilences | read-only | mandatory | This statistic is the number of received periods of non-silence. |
| 1.3.6.1.4.1.495.2.1.5.9.2.32 | ScalartbRxBadCrcFrames | read-only | mandatory | This statistic tracks the number of received frames with FCS (or CRC) errors and the E-bit reset. |
| 1.3.6.1.4.1.495.2.1.5.9.2.33 | ScalartbRxEBitSetFrames | read-only | mandatory | This statistic counts the number of received frames with the E-bit set in the end delimiter. The E bit, or error bit, is set by the regenerative repeater (head… |
| 1.3.6.1.4.1.495.2.1.5.9.2.34 | ScalartbRxFrameFragments | read-only | mandatory | This statistic represents the number of frame fragments (start delimiter (SD) not followed by a valid end delimiter (ED)). A valid frame consists of only data … |
| 1.3.6.1.4.1.495.2.1.5.9.2.35 | ScalartbRxFrameTooLongs | read-only | mandatory | This statistic is the number of received frames tart are too long (>8 KBytes). |
| 1.3.6.1.4.1.495.2.1.5.9.2.36 | ScalartbNbNoFdBdErrors | read-only | mandatory | This statistic counts the number of frames that were not received because there were not enough frame descriptors or there were not enough buffers. |
| 1.3.6.1.4.1.495.2.1.5.9.2.37 | ScalartbNbOverruns | read-only | mandatory | This statistic represents the number of times the TBC detected a FIFO overrun during receive. |