18 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.495.2.1.6.42.1Tablev34SlotTablenot-accessiblemandatoryDescribes a table that contains configuration information about each V34 modem and its associated hardware port.
1.3.6.1.4.1.495.2.1.6.42.1.1Rowv34SlotEntrynot-accessiblemandatoryDescribes the configuration information applied to a specific V34 modem and its associated hardware port.
1.3.6.1.4.1.495.2.1.6.42.1.1.1Columnv34SlotNumberread-onlymandatoryIdentifies a numerical value applied to the modem. Each device has a unique number.
1.3.6.1.4.1.495.2.1.6.42.1.1.2Columnv34SlotAliasread-writemandatoryAssigns a name used for the alias. Each modem requires a unique name. You may not assign the same name twice. Default Value: none Range of Values: Up to twelve…
1.3.6.1.4.1.495.2.1.6.42.1.1.3Columnv34SlotRowStatusread-writemandatoryDetermines the status of the objects in in a table row. Default Value: none Options: invalid (1): row is flagged, after next reset the values will be disabled …
1.3.6.1.4.1.495.2.1.6.42.1.1.4Columnv34SlotStatusread-onlymandatoryIdentifies the presence or absence of a V.34 modem in the slot and if present, whether it has failed initialization. Default Value: none Options: v34-not-prese…
1.3.6.1.4.1.495.2.1.6.42.1.1.5Columnv34SlotModemStringread-writemandatoryDetermines a string to be sent to the modem upon initialization. Default Value: none Range of Values: 0-32 alphanumberic characters Configuration Changed: admi…
1.3.6.1.4.1.495.2.1.6.42.1.1.6Columnv34SlotDialNumberread-writemandatorySpecifies the number used to dial the remote modem. Default Value: none Range of Values: An octet string of 12 numeric characters Configuration Changed: admini…
1.3.6.1.4.1.495.2.1.6.42.1.1.7Columnv34SlotAnswerModeread-writemandatoryDetermines whether the device will answer an incoming call. Default Value: answer-enabled (2) Options: answer-disabled (1) answer-enabled (2) test-mode (3) Con…
1.3.6.1.4.1.495.2.1.6.42.1.1.8Columnv34SlotSpeedStatusread-onlymandatoryIdentifies the connection rate operative during the current dial call only. Default Value: none Options: speed-0-300 (1) speed-600 (2) speed-1200 (3) speed-240…
1.3.6.1.4.1.495.2.1.6.42.1.1.9Columnv34SlotRetrainStatusread-onlymandatoryIdentifies whether the modem is retraining or not. It is only applicable while the modem is on-line. Default Value: none Options: no-retraining (1) retraining …
1.3.6.1.4.1.495.2.1.6.42.1.1.10Columnv34SlotHookStatusread-onlymandatoryIdentifies whether the modem is 'off-hook' (connected to the telephone line), or 'on-hook' (disconnected). Default Value: none Options: on-hook (1) off-hook (2)
1.3.6.1.4.1.495.2.1.6.42.1.1.11Columnv34SlotRingStatusread-onlymandatoryIdentifies when the modem detects a ring signal from the telephone line. Default Value: none Options: no-ring (1) ring (2)
1.3.6.1.4.1.495.2.1.6.42.1.1.12Columnv34SlotDsrStatusread-onlymandatoryIdentifies the data transfer state of the modem by the status of the Data Set Ready (DSR) signal . Default Value: none Options dsr-deasserted (1): data transfe…
1.3.6.1.4.1.495.2.1.6.42.1.1.13Columnv34SlotDtrStatusread-onlymandatoryIdentifies the status of the Data Terminal Ready (DTR) signal that the motherboard uses to dial the pre-stored phone number (if in originate mode) or to enable…
1.3.6.1.4.1.495.2.1.6.42.1.1.14Columnv34SlotModelread-onlymandatoryIdentifies the model number of the Printed Circuit Board (PCB) as an integer value from 0 to 7. Default Value: none Range of Values: 0-7
1.3.6.1.4.1.495.2.1.6.42.1.1.15Columnv34SlotRevisionread-onlymandatoryIdentifies the revision number of the PCB as an integer value from 0 to 15. Default Value: none Range of Values: 0-15
1.3.6.1.4.1.495.2.1.6.42.1.1.16Columnv34SlotEcoread-onlymandatoryIdentifies the Engineering Change Order (ECO) level of the PCB as an integer value from 0 to 15. Default Value: none Range of Values: 0-15