IEEE8021-PSFP-MIB
78 objects
The Bridge MIB module for managing devices that support the Per-Stream Filtering and Policing enhancements for IEEE 802.1Q Bridges. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q. Copyright (C) IEEE (2018). This version of this MIB module is part of IEEE Std 802.1Q; see the draft itself for full legal notices.
Imported Objects
| IEEE8021-BRIDGE-MIB | ieee8021BridgeBaseComponentId |
| IEEE8021-ST-MIB | IEEE8021STPTPtimeValue |
| IEEE8021-TC-MIB | ieee802dot1mibs |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Counter64 Integer32 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | RowStatus TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.111.2.802.1.1.31 | Identityieee8021PSFPMib | The Bridge MIB module for managing devices that support the Per-Stream Filtering and Policing enhancements for IEEE 802.1Q Bridges. Unless otherwise indicated,… | ||
| 1.3.111.2.802.1.1.31.0 | Nodeieee8021PSFPNotifications | |||
| 1.3.111.2.802.1.1.31.1 | Nodeieee8021PSFPObjects | |||
| 1.3.111.2.802.1.1.31.1.1 | Nodeieee8021PSFPStreamFilterParameters | |||
| 1.3.111.2.802.1.1.31.1.1.1 | Tableieee8021PSFPStreamFilterTable | not-accessible | current | A table that contains the per-filter instance manageable parameters for stream filters. A row in the table exists for each stream filter instance. associated w… |
| 1.3.111.2.802.1.1.31.1.1.1.1 | Rowieee8021PSFPStreamFilterEntry | not-accessible | current | A list of objects that contains the manageable parameters for stream filters for a Bridge component. |
| 1.3.111.2.802.1.1.31.1.1.1.1.1 | Columnieee8021PSFPStreamFilterInstance | not-accessible | current | The StreamFilterInstance parameter is an index into the StreamFilterTable. The value of this object MUST be retained across reinitializations of the management… |
| 1.3.111.2.802.1.1.31.1.1.1.1.2 | Columnieee8021PSFPStreamHandleSpec | read-create | current | The StreamHandleSpec parameter contains a stream identifier specification value. A value of -1 denotes the wild card value; all positive values denote stream i… |
| 1.3.111.2.802.1.1.31.1.1.1.1.3 | Columnieee8021PSFPPrioritySpec | read-create | current | The PrioritySpec parameter contains a priority specification value. A value of -1 denotes the wild card value; zero or positive values denote priority values. … |
| 1.3.111.2.802.1.1.31.1.1.1.1.4 | Columnieee8021PSFPStreamGateInstanceID | read-create | current | The StreamGateInstance parameter contains the index of an entry in the Stream Gate Table. The value of this object MUST be retained across reinitializations of… |
| 1.3.111.2.802.1.1.31.1.1.1.1.5 | Columnieee8021PSFPFilterSpecificationList | read-create | current | The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the conten… |
| 1.3.111.2.802.1.1.31.1.1.1.1.6 | Columnieee8021PSFPMatchingFramesCount | read-only | current | The MatchingFramesCount counter counts received frames that match this stream filter. |
| 1.3.111.2.802.1.1.31.1.1.1.1.7 | Columnieee8021PSFPPassingFramesCount | read-only | current | The PassingFramesCount counter counts received frames that pass the gate associated with this stream filter. |
| 1.3.111.2.802.1.1.31.1.1.1.1.8 | Columnieee8021PSFPNotPassingFramesCount | read-only | current | The NotPassingFramesCount counter counts received frames that do not pass the gate associated with this stream filter. |
| 1.3.111.2.802.1.1.31.1.1.1.1.9 | Columnieee8021PSFPPassingSDUCount | read-only | current | The PassingSDUCount counter counts received frames that pass the SDU size filter specification associated with this stream filter. |
| 1.3.111.2.802.1.1.31.1.1.1.1.10 | Columnieee8021PSFPNotPassingSDUCount | read-only | current | The NotPassingSDUCount counter counts received frames that do not pass the SDU size filter specification associated with this stream filter. |
| 1.3.111.2.802.1.1.31.1.1.1.1.11 | Columnieee8021PSFPREDFramesCount | read-only | current | The REDFramesCount counter counts received frames that were discarded as a result of the operation of the flow meter. |
| 1.3.111.2.802.1.1.31.1.1.1.1.12 | Columnieee8021PSFPStreamBlockedDueToOversizeFrameEnable | read-create | current | The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame fu… |
| 1.3.111.2.802.1.1.31.1.1.1.1.13 | Columnieee8021PSFPStreamBlockedDueToOversizeFrame | read-create | current | The ieee8021PSFPStreamBlockedDueToOversizeFrame object contains a Boolean value that indicates whether, if the ieee8021PSFPStreamBlockedDueToOversizeFrame func… |
| 1.3.111.2.802.1.1.31.1.1.1.1.14 | Columnieee8021PSFPStreamFilterEntryRowStatus | read-create | current | The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
| 1.3.111.2.802.1.1.31.1.2 | Nodeieee8021PSFPStreamGateParameters | |||
| 1.3.111.2.802.1.1.31.1.2.1 | Tableieee8021PSFPStreamGateTable | not-accessible | current | A table that contains the per-gate instance manageable parameters for stream gate scheduling. For a given Bridge component, a row in the table exists for each … |
| 1.3.111.2.802.1.1.31.1.2.1.1 | Rowieee8021PSFPStreamGateEntry | not-accessible | current | A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component. |
| 1.3.111.2.802.1.1.31.1.2.1.1.1 | Columnieee8021PSFPStreamGateInstance | not-accessible | current | The StreamGateInstance parameter is an index into the StreamGateTable. The value of this object MUST be retained across reinitializations of the management sys… |
| 1.3.111.2.802.1.1.31.1.2.1.1.2 | Columnieee8021PSFPGateEnabled | read-create | current | The GateEnabled parameter determines whether the stream gate is active (true) or inactive (false). The value of this object MUST be retained across reinitializ… |
| 1.3.111.2.802.1.1.31.1.2.1.1.3 | Columnieee8021PSFPAdminGateStates | read-create | current | The administrative value of the GateStates parameter for the stream gate. The open value indicates that the gate is open, the closed value indicates that the g… |
| 1.3.111.2.802.1.1.31.1.2.1.1.4 | Columnieee8021PSFPOperGateStates | read-only | current | The operational value of the GateStates parameter for the stream gate. The open value indicates that the gate is open, the closed value indicates that the gate… |
| 1.3.111.2.802.1.1.31.1.2.1.1.5 | Columnieee8021PSFPAdminControlListLength | read-create | current | The administrative value of the ListMax parameter for the gate. The integer value indicates the number of entries (TLVs) in the AdminControlList. The value of … |
| 1.3.111.2.802.1.1.31.1.2.1.1.6 | Columnieee8021PSFPOperControlListLength | read-only | current | The operational value of the ListMax parameter for the gate. The integer value indicates the number of entries (TLVs) in the OperControlList. |
| 1.3.111.2.802.1.1.31.1.2.1.1.7 | Columnieee8021PSFPAdminControlList | read-create | current | The administrative value of the ControlList parameter for the gate. The octet string value represents the contents of the control list as an ordered list of en… |
| 1.3.111.2.802.1.1.31.1.2.1.1.8 | Columnieee8021PSFPOperControlList | read-only | current | The operational value of the ControlList parameter for the gate. The octet string value represents the contents of the control list as an ordered list of entri… |
| 1.3.111.2.802.1.1.31.1.2.1.1.9 | Columnieee8021PSFPAdminCycleTimeNumerator | read-create | current | The administrative value of the numerator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rationa… |
| 1.3.111.2.802.1.1.31.1.2.1.1.10 | Columnieee8021PSFPAdminCycleTimeDenominator | read-create | current | The administrative value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a ratio… |
| 1.3.111.2.802.1.1.31.1.2.1.1.11 | Columnieee8021PSFPOperCycleTimeNumerator | read-only | current | The operational value of the numerator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational n… |
| 1.3.111.2.802.1.1.31.1.2.1.1.12 | Columnieee8021PSFPOperCycleTimeDenominator | read-only | current | The operational value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational… |
| 1.3.111.2.802.1.1.31.1.2.1.1.13 | Columnieee8021PSFPAdminCycleTimeExtension | read-create | current | The administrative value of the CycleTimeExtension parameter for the gate. The value is an unsigned integer number of nanoseconds. The value of this object MUS… |
| 1.3.111.2.802.1.1.31.1.2.1.1.14 | Columnieee8021PSFPOperCycleTimeExtension | read-only | current | The operational value of the CycleTimeExtension parameter for the gate. The value is an unsigned integer number of nanoseconds. |
| 1.3.111.2.802.1.1.31.1.2.1.1.15 | Columnieee8021PSFPAdminBaseTime | read-create | current | The administrative value of the BaseTime parameter for the gate. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of sec… |
| 1.3.111.2.802.1.1.31.1.2.1.1.16 | Columnieee8021PSFPOperBaseTime | read-only | current | The operationsl value of the BaseTime parameter for the gate. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of second… |
| 1.3.111.2.802.1.1.31.1.2.1.1.17 | Columnieee8021PSFPConfigChange | read-create | current | The ConfigChange parameter signals the start of a configuration change for the gate when it is set to TRUE. This should only be done when the various administr… |
| 1.3.111.2.802.1.1.31.1.2.1.1.18 | Columnieee8021PSFPConfigChangeTime | read-only | current | The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of s… |
| 1.3.111.2.802.1.1.31.1.2.1.1.19 | Columnieee8021PSFPTickGranularity | read-only | current | The granularity of the cycle time clock, represented as an unsigned number of tenths of nanoseconds. The value of this object MUST be retained across reinitial… |
| 1.3.111.2.802.1.1.31.1.2.1.1.20 | Columnieee8021PSFPCurrentTime | read-only | current | The current time, in PTPtime, as maintained by the local system. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of sec… |
| 1.3.111.2.802.1.1.31.1.2.1.1.21 | Columnieee8021PSFPConfigPending | read-only | current | The value of the ConfigPending state machine variable. The value is TRUE if a configuration change is in progress but has not yet completed. |
| 1.3.111.2.802.1.1.31.1.2.1.1.23 | Columnieee8021PSFPConfigChangeError | read-only | current | A counter of the number of times that a re-configuration of the traffic schedule has been requested with the old schedule still running and the requested base … |
| 1.3.111.2.802.1.1.31.1.2.1.1.24 | Columnieee8021PSFPAdminIPV | read-create | current | The administrative value of the IPV parameter for the gate. A value of -1 denotes the null value. |
| 1.3.111.2.802.1.1.31.1.2.1.1.25 | Columnieee8021PSFPOperIPV | read-create | current | The operational value of the IPV parameter for the gate. A value of -1 denotes the null value. |
| 1.3.111.2.802.1.1.31.1.2.1.1.26 | Columnieee8021PSFPGateClosedDueToInvalidRxEnable | read-create | current | The PSFPGateClosedDueToInvalidRxEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToInvalidRx function is enabled (TRUE) or di… |
| 1.3.111.2.802.1.1.31.1.2.1.1.27 | Columnieee8021PSFPGateClosedDueToInvalidRx | read-create | current | The PSFPGateClosedDueToInvalidRx object contains a Boolean value that indicates whether, if the PSFPGateClosedDueToInvalidRx function is enabled, all frames ar… |
| 1.3.111.2.802.1.1.31.1.2.1.1.28 | Columnieee8021PSFPGateClosedDueToOctetsExceededEnable | read-create | current | The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (T… |
| 1.3.111.2.802.1.1.31.1.2.1.1.29 | Columnieee8021PSFPGateClosedDueToOctetsExceeded | read-create | current | The PSFPGateClosedDueToOctetsExceeded parameter contains a Boolean value that indicates whether, if the PSFPGateClosedDueToOctetsExceeded function is enabled, … |
| 1.3.111.2.802.1.1.31.1.2.1.1.30 | Columnieee8021PSFPStreamGateEntryRowStatus | read-create | current | The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
| 1.3.111.2.802.1.1.31.1.3 | Nodeieee8021PSFPFlowMeterParameters | |||
| 1.3.111.2.802.1.1.31.1.3.1 | Tableieee8021PSFPFlowMeterTable | not-accessible | current | A table that contains the per-meter instance manageable parameters for flow meters. For a given Bridge component, a row in the table exists for each flow meter… |
| 1.3.111.2.802.1.1.31.1.3.1.1 | Rowieee8021PSFPFlowMeterEntry | not-accessible | current | A list of objects that contains the manageable parameters for flow meters for a Bridge component. |
| 1.3.111.2.802.1.1.31.1.3.1.1.1 | Columnieee8021PSFPFlowMeterInstance | not-accessible | current | The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management syste… |
| 1.3.111.2.802.1.1.31.1.3.1.1.2 | Columnieee8021PSFPFlowMeterCIR | read-create | current | The FlowMeterCIR parameter contains an integer value that represents the CIR value for the flow meter, in bit/second. The value of this object MUST be retained… |
| 1.3.111.2.802.1.1.31.1.3.1.1.3 | Columnieee8021PSFPFlowMeterCBS | read-create | current | The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained acr… |
| 1.3.111.2.802.1.1.31.1.3.1.1.4 | Columnieee8021PSFPFlowMeterEIR | read-create | current | The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained… |
| 1.3.111.2.802.1.1.31.1.3.1.1.5 | Columnieee8021PSFPFlowMeterEBS | read-create | current | The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained acr… |
| 1.3.111.2.802.1.1.31.1.3.1.1.6 | Columnieee8021PSFPFlowMeterCF | read-create | current | The FlowMeterCF parameter contains an integer value that represents the CF value for the flow meter, as an integer value 0 or 1. The value of this object MUST … |
| 1.3.111.2.802.1.1.31.1.3.1.1.7 | Columnieee8021PSFPFlowMeterCM | read-create | current | The FlowMeterCM parameter contains an integer value that represents the CM value for the flow meter, as an enumerated value indicating colorBlind(1) or colorAw… |
| 1.3.111.2.802.1.1.31.1.3.1.1.8 | Columnieee8021PSFPFlowMeterDropOnYellow | read-create | current | The FlowMeterDropOnYellow parameter contains a Boolean value that indicates whether yellow frames are dropped (TRUE) or have drop_eligible set to TRUE (FALSE).… |
| 1.3.111.2.802.1.1.31.1.3.1.1.9 | Columnieee8021PSFPFlowMeterMarkAllFramesRedEnable | read-create | current | The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALS… |
| 1.3.111.2.802.1.1.31.1.3.1.1.10 | Columnieee8021PSFPFlowMeterMarkAllFramesRed | read-create | current | The FlowMeterMarkAllFramesRed parameter contains a Boolean value that indicates whether, if the MarkAllFramesRed function is enabled, all frames are to be disc… |
| 1.3.111.2.802.1.1.31.1.3.1.1.11 | Columnieee8021PSFPFlowMeterEntryRowStatus | read-create | current | The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
| 1.3.111.2.802.1.1.31.1.4 | Nodeieee8021PSFPStreamParameters | |||
| 1.3.111.2.802.1.1.31.1.4.1 | Tableieee8021PSFPStreamParameterTable | not-accessible | current | A table that contains per-Bridge component manageable parameters for PSFP. A row in the table exists for each Bridge component. All writable objects in this ta… |
| 1.3.111.2.802.1.1.31.1.4.1.1 | Rowieee8021PSFPStreamParameterEntry | not-accessible | current | A list of objects that contains the manageable parameters for flow meters for a Bridge component. |
| 1.3.111.2.802.1.1.31.1.4.1.1.1 | Columnieee8021PSFPMaxStreamFilterInstances | read-only | current | The MaxStreamFilterInstances parameter defines the maximum number of stream filter instances that are supported by this Bridge component. |
| 1.3.111.2.802.1.1.31.1.4.1.1.2 | Columnieee8021PSFPMaxStreamGateInstances | read-only | current | The MaxStreamGateInstances parameter defines the maximum number of stream gate instances that are supported by this Bridge component. |
| 1.3.111.2.802.1.1.31.1.4.1.1.3 | Columnieee8021PSFPMaxFlowMeterInstances | read-only | current | The MaxFlowMeterInstances parameter defines the maximum number of flow meter instances that are supported by this Bridge component. |
| 1.3.111.2.802.1.1.31.1.4.1.1.4 | Columnieee8021PSFPSupportedListMax | read-only | current | The SupportedListMax parameter defines the The maximum value supported by this Bridge component of the AdminControlListLength and OperControlListLength paramet… |
| 1.3.111.2.802.1.1.31.2 | Nodeieee8021PSFPConformance | |||
| 1.3.111.2.802.1.1.31.2.1 | Nodeieee8021PSFPCompliances | |||
| 1.3.111.2.802.1.1.31.2.1.1 | Complianceieee8021PSFPCompliance | current | The compliance statement for devices supporting PSFP. Support of the objects defined in this MIB module also requires support of the IEEE8021-BRIDGE-MIB; the p… | |
| 1.3.111.2.802.1.1.31.2.2 | Nodeieee8021PSFPGroups | |||
| 1.3.111.2.802.1.1.31.2.2.1 | Groupieee8021PSFPObjectsGroup | current | Objects that allow management of PSFP. |