MIB Viewer

INTELCORPORATION-MULTI-FLEX-SERVER-BLADES-MIB

85 objects
Blade Module of the Multi-Flex Server
OIDNameAccessStatusDescription
1.3.6.1.4.1.343.2.19.1.1.1.12IdentitymultiFlexServerBladesMibModuleBlade Module of the Multi-Flex Server
1.3.6.1.4.1.343.2.19.1.2.2.2.12GroupbladeGroupcurrentDescription.
1.3.6.1.4.1.343.2.19.1.2.10.12ScalarmaxBladesread-onlycurrentMaximum number of Blades possible in this chassis.
1.3.6.1.4.1.343.2.19.1.2.10.22ScalarnumOfBladesread-onlycurrentThe number of Blades in the system.
1.3.6.1.4.1.343.2.19.1.2.10.32ScalarbladePresenceMaskread-onlycurrentASCII representation of bit string reflecting the presence of the blades with the left most 'bit' being bit 1 and maxBlades bits being represented. Thus, '0100…
1.3.6.1.4.1.343.2.19.1.2.10.202IdentitybladescurrentContainer for Blade specific information as well as all components logically contained within.
1.3.6.1.4.1.343.2.19.1.2.10.202.1TablebladeTablenot-accessiblecurrentEach row describes a Blade in the chassis. Note, all blade rows possible for a chassis are present so that the presence field is accessible even when the blade…
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1RowbladeEntrynot-accessiblecurrentIndividual blade entry
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.1ColumnbladeSlotIdread-onlycurrentSlot number which the blade current occupies (or would occupy).
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.2ColumnbladePresenceread-onlycurrentcolumn used to flag the existence of a particular FRU
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.3ColumnmaxFrusread-onlycurrentGiven a board, the Maximum number of FRUs for this board. This parameter is related to the bladeFruPresenceMask as it defines the number of FRUs to be represen…
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.4ColumnnumOfFrusread-onlycurrentThe number FRUs present on the board
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.5ColumnbladeFruPresenceMaskread-onlycurrentASCII representation of bit string reflecting the presence of the FRUs with the left most 'bit' being bit 1 and maxFrus bits being represented. bit 1 - blade, …
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.6ColumnbladePowerLedread-writecurrentState of the Power LED on the Blade (and optionally power control blade)
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.7ColumnbladeFaultLedread-onlycurrentState of the Fault LED on the Blade
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.8ColumnbladePresenceLedread-writecurrentState of the Presence LED on the Blade (and optionally intiate identification)
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.9ColumnbladeBmcFirmwareVersionread-onlycurrentTextual BMC Version of this blade.
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.10ColumnbladeBootBlockVersionread-onlycurrentTextual Boot Block Version of this blade.
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.11ColumnbladeBiosVersionread-onlycurrentTextual BIOS Version of this blade.
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.12ColumnbladeConsoleRedirectionread-onlycurrentConsole redirection configuration within BIOS
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.13ColumnbladeLegacyOsRedirectionread-onlycurrentLegacy OS Redirection configuration within BIOS
1.3.6.1.4.1.343.2.19.1.2.10.202.1.1.14ColumnbladeBootCountread-onlycurrentNumber of times the blade has booted (since manufactured or NVRAM cleared) Will be 0 if unknown (e.g., blade hasn't been powered on at least once since inserti…
1.3.6.1.4.1.343.2.19.1.2.10.202.2TablebladeFruTablenot-accessiblecurrentEach row describes a FRU associated with (and including) a Blade in the chassis There will always be 2 FRU entries for every blade (with the presence field mar…
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1RowbladeFruEntrynot-accessiblecurrentblade & SubFRU common information.
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.1ColumnbladeFruTyperead-onlycurrentcolumn used to identify a particular FRU. FRU 1 is the blade, itself, FRU 2 is the mezzanine card
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.2ColumnbladeFruPresenceread-onlycurrentcolumn used to flag the existence of a particular FRU
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.3ColumnbladeFruVendorread-onlycurrentDevice manufacturer
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.4ColumnbladeFruMfgDateread-onlycurrentManufacture date/time
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.5ColumnbladeFruDeviceNameread-onlycurrentDevice Name
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.6ColumnbladeFruPartread-onlycurrentDevice Part Number
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.7ColumnbladeFruSerialNoread-onlycurrentDevice Serial Number
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.8ColumnbladeFruMaximumPowerread-onlycurrentStatic maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device…
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.9ColumnbladeFruNominalPowerread-onlycurrentStatic Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device…
1.3.6.1.4.1.343.2.19.1.2.10.202.2.1.10ColumnbladeFruAssetTagread-onlycurrentAsset Tag # of device
1.3.6.1.4.1.343.2.19.1.2.10.202.3TablebladeNicTablenot-accessiblecurrentEach row describes a NIC associated with a blade from the system memory as described by the blades SMBIOS entries. For future compatibility, this table is spar…
1.3.6.1.4.1.343.2.19.1.2.10.202.3.1RowbladeNicEntrynot-accessiblecurrentOverall NIC information per blade information
1.3.6.1.4.1.343.2.19.1.2.10.202.3.1.1ColumnbladeNicread-onlycurrentNIC associated with blade (both onboard and optional Mezzanine card) as found within the SMBIOS data for the blade
1.3.6.1.4.1.343.2.19.1.2.10.202.4TablebladeProcessorTablenot-accessiblecurrentEach row describes a Processor associated with a Blade in the chassis as described by the blades SMBIOS entries. As there are multiple Processors available per…
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1RowbladeProcessorEntrynot-accessiblecurrentProcessor(s) per blade information
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.1Columnhandlenot-accessiblecurrentUnique handle within the SMBIOS table for a specific blade which lays out the assorted record types.
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.2ColumnbladeProcessorSocketread-onlycurrentString returned by SMBIOS designating the socket location of the CPU for the indexed blade. The string is returned by the BIOS and is arbitrary as determined b…
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.3ColumnbladeProcessorPresenceread-onlycurrentcolumn used to flag the existence of a particular CPU
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.4ColumnbladeProcessorTyperead-onlycurrentSMBIOS string representing type of Processor in this slot
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.5ColumnbladeProcessorFamilyread-onlycurrentString representing SMBIOS data for the processor family type
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.6ColumnbladeProcessorManufacturerread-onlycurrentString representing SMBIOS data for the Manufacturer of the Processor
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.7ColumnbladeProcessorIDread-onlycurrentSMBIOS string containing the Processor ID field which contains processor-specific information that describes the processor's features.
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.8ColumnbladeProcessorVersionread-onlycurrentString representing SMBIOS data describing the Processor
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.9ColumnbladeProcessorVoltageread-onlycurrentSMBIOS string representing the voltage(s) the processor is capable of
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.10ColumnbladeProcessorExtClockread-onlycurrentSMBIOS value of the External Clock Frequency, in MHZ. If the value is unknown, the field is set to 0
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.11ColumnbladeProcessorMaxSpeedread-onlycurrentSMBIOS value of the Maximum processor speed (in MHz) supported by the system for this processor socket. If the value is unknown, the field is set to 0. Note: T…
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.12ColumnbladeProcessorStatusread-onlycurrentString representing SMBIOS data describing CPU status information
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.13ColumnbladeProcessorUpgraderead-onlycurrentString representing SMBIOS data describing the CPU 'Upgrade' or how the processor is located on the blade
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.14ColumnbladeProcessorSerialNoread-onlycurrentSMBIOS string of the serial number of this processor. This value is set by the manufactureer and normally not changeable.
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.15ColumnbladeProcessorAssetTagread-onlycurrentSMBIOS string of the asset tag of this processor.
1.3.6.1.4.1.343.2.19.1.2.10.202.4.1.16ColumnbladeProcessorPartNoread-onlycurrentSMBIOS string of the part number of this processor. This value is set by the manufactureer and normally not changeable.
1.3.6.1.4.1.343.2.19.1.2.10.202.5TablebladeMemorySummaryTablenot-accessiblecurrentEach row describes the overall summary of the memory configuration for a given blade in the chassis as described by the blades SMBIOS entries. For future compa…
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1RowbladeMemorySummaryEntrynot-accessiblecurrentOverall memory configuration summary per blade information
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.1ColumnbladeMSMaxDevicesread-onlycurrentThe number of slots or sockets available for Memory Devices on the board.
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.2ColumnbladeMSNumOfDevicesread-onlycurrentThe number of slots or sockets populated with Memory Devices on the board.
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.3ColumnbladeMSCapacityread-onlycurrentThe maximum memory capacity in MB for this array.
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.4ColumnbladeMSTotalSizeread-onlycurrentTotal size in MB of all memory physically installed
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.5ColumnbladeMSEffectiveSizeread-onlycurrentMemory available after deducting for failed and redundant memory units
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.6ColumnbladeMSNumFailedread-onlycurrentTotal Number of failed memory devices
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.7ColumnbladeMSDisabledSizeread-onlycurrentTotal size in MB of all disabled memory
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.8ColumnbladeMSSpareSizeread-onlycurrentTotal size in MB of all spare memory (see bladeMSRasPossible & bladeMSRasConfiguration columns)
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.9ColumnbladeMSRasPossibleread-onlycurrentRAS Configuration Possible
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.10ColumnbladeMSRasConfigurationread-onlycurrentRAS Configuration Possible
1.3.6.1.4.1.343.2.19.1.2.10.202.5.1.11ColumnbladeMSErrorCorrectionread-onlycurrentThe primary hardware error correction or detection method supported
1.3.6.1.4.1.343.2.19.1.2.10.202.6TablebladeMemoryTablenot-accessiblecurrentEach row describes an individual memory device for system memory given a specific blade in the chassis as described by the blades SMBIOS entries. For future co…
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1RowbladeMemoryEntrynot-accessiblecurrentOverall memory device per blade information
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.1ColumnbladeMemTotalWidthread-onlycurrentThe total width, in bits, of this memory device, including any check or error-correction bits. If there are no error-correction bits, this value should be equa…
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.2ColumnbladeMemDataWidthread-onlycurrentThe data width, in bits, of this memory device. If 0 and bladeMemTotalWidth is 8 indicates that the device is being used solely to provide 8 error-correction b…
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.3ColumnbladeMemSizeread-onlycurrentThe size of the memory device. If the value is 0, no memory device is installed in the socket (shouldn't occur as the table is sparsely populated); if the size…
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.4ColumnbladeMemGranularityread-onlycurrentThe granularity of the bladeMemSize
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.5ColumnbladeMemFormFactorread-onlycurrentThe implementation form factor for this memory device.
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.6ColumnbladeMemDeviceSetread-onlycurrentIdentifies when the Memory Device is one of a set of Memory Devices that must be populated with all devices of the same type and size and the set to which this…
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.7ColumnbladeMemLocationread-onlycurrentString that identifies the physically labeled socket or board position where the memory device is located
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.8ColumnbladeMemBankread-onlycurrentString that identifies the physically labeled bank where where the memory device is located
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.9ColumnbladeMemTyperead-onlycurrentThe type of memory used in this device
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.10ColumnbladeMemTypeDetailread-onlycurrentThe type of memory used in this device
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.11ColumnbladeMemSpeedread-onlycurrentIdentifies the speed of the device in megahertz (MHz).
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.12ColumnbladeMemManufacturerread-onlycurrentManufacturer of this memory device
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.13ColumnbladeMemSerialNoread-onlycurrentSerial Number of this memory device
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.14ColumnbladeMemAssetTagread-onlycurrentAsset Tag of this memory device
1.3.6.1.4.1.343.2.19.1.2.10.202.6.1.15ColumnbladeMemPartread-onlycurrentPart Number of this memory device