MIB Viewer

LENOVO-XCC-ALERT-MIB

54 objects
This MIB is used by the XCC to define traps for Alert conditions detected by the management firmware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.19046.11.1.158.5IdentitylenovoXCCAlertMIBThis MIB is used by the XCC to define traps for Alert conditions detected by the management firmware.
1.3.6.1.4.1.19046.11.1.158.5.0NodelenovoSpTrapTempCCritical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.19046.11.1.158.5.1NodelenovoSpTrapVoltCCritical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.19046.11.1.158.5.1Nodexcctrapg
1.3.6.1.4.1.19046.11.1.158.5.1.1ScalaraltDateTimeread-onlymandatoryTimestamp of Local Date and Time when alert was generated
1.3.6.1.4.1.19046.11.1.158.5.1.3ScalaraltSpTxtIdread-onlymandatorySP System Identification - Text Identification
1.3.6.1.4.1.19046.11.1.158.5.1.5ScalaraltSysUuidread-onlymandatoryHost System UUID(Universal Unique ID)
1.3.6.1.4.1.19046.11.1.158.5.1.6ScalaraltSysSernread-onlymandatoryHost System Serial Number
1.3.6.1.4.1.19046.11.1.158.5.1.8ScalaraltPriorityread-onlymandatoryAlert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery(8)
1.3.6.1.4.1.19046.11.1.158.5.1.9ScalaraltMsgTextread-onlymandatoryAlert Message Text
1.3.6.1.4.1.19046.11.1.158.5.1.10ScalaraltMsgIDread-onlymandatoryAlert Message ID
1.3.6.1.4.1.19046.11.1.158.5.1.11ScalaraltMsgIDPrefixread-onlymandatoryAlert Message ID
1.3.6.1.4.1.19046.11.1.158.5.1.12ScalaraltHostContactread-onlymandatoryHost Contact
1.3.6.1.4.1.19046.11.1.158.5.1.13ScalaraltHostLocationread-onlymandatoryHost Location
1.3.6.1.4.1.19046.11.1.158.5.1.14ScalaraltHostRoomIDread-onlymandatoryHost Location - Room ID
1.3.6.1.4.1.19046.11.1.158.5.1.15ScalaraltHostRackIDread-onlymandatoryHost Location - Rack ID
1.3.6.1.4.1.19046.11.1.158.5.1.16ScalaraltHostLowestUposread-onlymandatoryHost Location - Lowest U-position
1.3.6.1.4.1.19046.11.1.158.5.1.17ScalaraltHostBladeBayread-onlymandatoryHost Location - BladeBay
1.3.6.1.4.1.19046.11.1.158.5.1.18ScalaraltEventIDread-onlymandatoryEvent Identifier
1.3.6.1.4.1.19046.11.1.158.5.1.19ScalaraltServiceableread-onlymandatoryServiceability information.
1.3.6.1.4.1.19046.11.1.158.5.1.20ScalaraltTestread-onlymandatoryThis event generated for test purposes.
1.3.6.1.4.1.19046.11.1.158.5.1.21ScalaraltFailingFRUsread-onlymandatoryOrdered list of Failing FRU Numbers, separated by commas.
1.3.6.1.4.1.19046.11.1.158.5.1.22ScalaraltHostMTMread-onlymandatoryMachine Type and Model for failing host.
1.3.6.1.4.1.19046.11.1.158.5.1.23ScalaraltAuxDataread-onlymandatoryAuxiliary data that may be included for some events.
1.3.6.1.4.1.19046.11.1.158.5.1.24ScalaraltCommonEventIDread-onlymandatoryCommon Event Identifier
1.3.6.1.4.1.19046.11.1.158.5.1.25ScalaraltEventTyperead-onlymandatoryThe type of event
1.3.6.1.4.1.19046.11.1.158.5.1.26ScalaraltDetectorIDread-onlymandatoryReporting source of event
1.3.6.1.4.1.19046.11.1.158.5.1.27ScalaraltDIMMPartNumberread-onlymandatoryReporting DIMM part number information
1.3.6.1.4.1.19046.11.1.158.5.4NodelenovoSpTrapPowerCCritical Alert: Power failure.
1.3.6.1.4.1.19046.11.1.158.5.5NodelenovoSpTrapHdCCritical Alert: Hard disk drive failure.
1.3.6.1.4.1.19046.11.1.158.5.9NodelenovoSpTrapRdpsCCritical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.19046.11.1.158.5.10NodelenovoSpTrapRdpsNNon-Critical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.19046.11.1.158.5.11NodelenovoSpTrapFanCCritical Alert: Single Fan failure.
1.3.6.1.4.1.19046.11.1.158.5.12NodelenovoSpTrapTempNNon-Critical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.19046.11.1.158.5.13NodelenovoSpTrapVoltNNon-Critical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.19046.11.1.158.5.21NodelenovoSpTrapOsToSSystem Alert: OS Timeout value exceeded.
1.3.6.1.4.1.19046.11.1.158.5.22NodelenovoSpTrapAppSSystem Alert: Application Alert. Refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.158.5.23NodelenovoSpTrapPoffSSystem Alert: Power Off.
1.3.6.1.4.1.19046.11.1.158.5.24NodelenovoSpTrapPonSSystem Alert: Power On.
1.3.6.1.4.1.19046.11.1.158.5.25NodelenovoSpTrapBootSSystem Alert: System Boot Failure.
1.3.6.1.4.1.19046.11.1.158.5.26NodelenovoSpTrapLdrToSSystem Alert: OS Loader Timeout.
1.3.6.1.4.1.19046.11.1.158.5.27NodelenovoSpTrapPFASSystem Alert: Predictive Failure Analysis(PFA) information.
1.3.6.1.4.1.19046.11.1.158.5.30NodelenovoSpTrapRLoginSev-Off Alert: Event Remote Login.
1.3.6.1.4.1.19046.11.1.158.5.35NodelenovoSpTrapSysLogSSystem Alert: System Log 75% full.
1.3.6.1.4.1.19046.11.1.158.5.36NodelenovoSpTrapIhcCCritical Alert: Incompatible hardware configuration.
1.3.6.1.4.1.19046.11.1.158.5.37NodelenovoSpTrapNwChangeSSystem Alert: Network change notification.
1.3.6.1.4.1.19046.11.1.158.5.40NodelenovoSpTrapCPUCCritical Alert: CPU Error.
1.3.6.1.4.1.19046.11.1.158.5.41NodelenovoSpTrapMemoryCCritical Alert: Memory Error.
1.3.6.1.4.1.19046.11.1.158.5.42NodelenovoSpTrapCPUNNon-Critical Alert: CPU Error.
1.3.6.1.4.1.19046.11.1.158.5.43NodelenovoSpTrapMemoryNNon-Critical Alert: Memory Error.
1.3.6.1.4.1.19046.11.1.158.5.50NodelenovoSpTrapHardwareCCritical Alert: Other Failure - refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.158.5.60NodelenovoSpTrapHardwareNNon-Critical Alert: Warning - refer to Message ID for specific condition.
1.3.6.1.4.1.19046.11.1.158.5.164NodelenovoSpTrapPowerNNon-Critical Alert: Power.
1.3.6.1.4.1.19046.11.1.158.5.165NodelenovoSpTrapFanNNon-Critical Alert: Fan Error.