NMS520-MIB
95 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.498.8.2 | Nodenms520 | |||
| 1.3.6.1.4.1.498.8.2.1 | Scalarnms520MIBversion | read-only | mandatory | Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number… |
| 1.3.6.1.4.1.498.8.2.2 | Tablenms520UnitCfgTable | not-accessible | mandatory | The NMS520 Unit Configuration table. This table augments the GDC SC5520 Unit Configuration table, providing unit level configuration for each NMS520 device ins… |
| 1.3.6.1.4.1.498.8.2.2.1 | Rownms520UnitCfgEntry | not-accessible | mandatory | The NMS520 Unit Configuration table entry. The information in this entry augments the information in the corresponding entry in the GDC SC Unit Configuration t… |
| 1.3.6.1.4.1.498.8.2.2.1.1 | Columnnms520UnitCfgIndex | read-only | mandatory | The index value which uniquely identifies the NMS520 to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, and dro… |
| 1.3.6.1.4.1.498.8.2.2.1.2 | Columnnms520Nms510CompatibilityMode | read-write | mandatory | The NMS510 compatibility mode. This mode allows the NMS520 to behave in a manner compatible with that of the NMS510 in a DDSI multipoint circuit. If this objec… |
| 1.3.6.1.4.1.498.8.2.2.1.3 | Columnnms520PtToPtSentryTime | read-write | mandatory | The Point to point sentry time nms520PtToPtSentryTime, is used to control the amount of time between unsolicited alarm responses from a remote unit in a point … |
| 1.3.6.1.4.1.498.8.2.2.1.4 | Columnnms520AlarmHystTime | read-write | mandatory | The Alarm hysterysis time nms520AlarmHystTime, is used to control the amount of time a remote must wait between reporting unsolicited alarm conditions. A remot… |
| 1.3.6.1.4.1.498.8.2.2.1.5 | Columnnms520MtpointRmRspIntrvl | read-write | mandatory | The multipoint remote response interval nms520MtpointRmRspIntrvl, is used to control the amount of time between unsolicited alarm responses from a remote unit … |
| 1.3.6.1.4.1.498.8.2.2.1.6 | Columnnms520DtePortType | read-write | mandatory | The value auto(3), indicates that the DTE port is automatically being detected, and set. The rs232(1), will force the DTE port to EIA/TIA-232-E, and v35(2), wi… |
| 1.3.6.1.4.1.498.8.2.2.1.7 | Columnnms520DteCtsDelay | read-write | mandatory | RTS/CTS Delay options ctsOn(1) Forces both RTS and CTS On regardless of the state of the attached business equipment (the transmitter is On regardless of the s… |
| 1.3.6.1.4.1.498.8.2.2.1.8 | Columnnms520DteCtsDelayExt | read-write | mandatory | RTS/CTS Delay options extension ext0mSec(1) Used to enable options cts0mSec(2) or ctsFix3Char(3) from MIB object nms520DteCtsDelay. ext30mSec(2) Provides 30 ms… |
| 1.3.6.1.4.1.498.8.2.2.1.9 | Columnnms520FirmwareLevel | read-only | mandatory | |
| 1.3.6.1.4.1.498.8.2.2.1.10 | Columnnms520DaisyChainBps | read-write | mandatory | Indicates the data rate at which the management data is sent/received when the gdcNmsManagementSource is daisyChain(4). |
| 1.3.6.1.4.1.498.8.2.2.1.11 | Columnnms520AlarmCfgCountWindow | read-write | mandatory | The DDS Alarm Threshold Alarm Interval. It specifies the amount of time in minutes, 1 to 15 minutes, in which the threshold setting is to be exceeded for the a… |
| 1.3.6.1.4.1.498.8.2.2.1.12 | Columnnms520SoftReset | read-write | mandatory | This object will cause software reset in dataset. |
| 1.3.6.1.4.1.498.8.2.2.1.13 | Columnnms520FrontPanelInhibit | read-write | mandatory | Inhibits all front panel test switches. If a test switch is activated while inhibited it will simply be ignored. If enabled via the nms520FrontPanelEnable obje… |
| 1.3.6.1.4.1.498.8.2.2.1.14 | Columnnms520FrontPanelEnable | read-write | mandatory | Enables all front panel test switches. If a test switch is activated while inhibited, via the nms520FrontPanelInhibit object, it will simply be ignored. If ena… |
| 1.3.6.1.4.1.498.8.2.2.1.15 | Columnnms520HdlcInvert | read-write | mandatory | Primary data invert option. Will enhance the quality of data when network does not provide B8Z5. Primarily used with DDS II 56k |
| 1.3.6.1.4.1.498.8.2.2.1.16 | Columnnms520PiggyBackDetect | read-only | mandatory | If set to 2 then either a Data Rate Adadaptor or 530 card is installed. |
| 1.3.6.1.4.1.498.8.2.2.1.17 | Columnnms520UnitType | read-only | mandatory | with IFP(2) means that the unit has a LCD configurable display. single-height(1) means that the unit does NOT have a LCD configurable display. |
| 1.3.6.1.4.1.498.8.2.2.1.18 | Columnnms520ExtPortCtrlOut1 | read-write | mandatory | This option sets the external output state (on/off) of the current network element and displays the external output. |
| 1.3.6.1.4.1.498.8.2.2.1.19 | Columnnms520ExtPortCtrlOut2 | read-write | mandatory | This option sets the external output state (on/off) of the current network element and displays the external output. |
| 1.3.6.1.4.1.498.8.2.4 | Nodenms520AlarmData | |||
| 1.3.6.1.4.1.498.8.2.4.1 | Nodenms520NoResponseAlm | |||
| 1.3.6.1.4.1.498.8.2.4.2 | Nodenms520DiagRxErrAlm | |||
| 1.3.6.1.4.1.498.8.2.4.3 | Nodenms520PowerUpAlm | |||
| 1.3.6.1.4.1.498.8.2.4.4 | Nodenms520EEChkSumErrAlm | |||
| 1.3.6.1.4.1.498.8.2.4.5 | Nodenms520StcLoopbackAlm | |||
| 1.3.6.1.4.1.498.8.2.4.6 | Nodenms520NoNtwkLoopCurrentAlm | |||
| 1.3.6.1.4.1.498.8.2.4.7 | Nodenms520LinePairsReversedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.8 | Nodenms520NoSignalAlm | |||
| 1.3.6.1.4.1.498.8.2.4.9 | Nodenms520FpTestAlm | |||
| 1.3.6.1.4.1.498.8.2.4.10 | Nodenms520StreamingAlm | |||
| 1.3.6.1.4.1.498.8.2.4.11 | Nodenms520DSRLossAlm | |||
| 1.3.6.1.4.1.498.8.2.4.12 | Nodenms520DTRLossAlm | |||
| 1.3.6.1.4.1.498.8.2.4.13 | Nodenms520DTPLossAlm | |||
| 1.3.6.1.4.1.498.8.2.4.14 | Nodenms520DCDLossAlm | |||
| 1.3.6.1.4.1.498.8.2.4.15 | Nodenms520RXDLossAlm | |||
| 1.3.6.1.4.1.498.8.2.4.16 | Nodenms520TXDLossAlm | |||
| 1.3.6.1.4.1.498.8.2.4.17 | Nodenms520TmShortedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.18 | Nodenms520DcdShortedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.19 | Nodenms520DsrShortedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.20 | Nodenms520CtsShortedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.21 | Nodenms520RxdShortedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.22 | Nodenms520RxcShortedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.23 | Nodenms520TxcShortedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.24 | Nodenms520DBURequestForScanAlm | |||
| 1.3.6.1.4.1.498.8.2.4.25 | Nodenms520DBUOnalm | |||
| 1.3.6.1.4.1.498.8.2.4.26 | Nodenms520DBUFailedAlm | |||
| 1.3.6.1.4.1.498.8.2.4.27 | Nodenms520NoDSUResponseAlm | |||
| 1.3.6.1.4.1.498.8.2.4.28 | Nodenms520NoDTEPollingAlm | |||
| 1.3.6.1.4.1.498.8.2.4.29 | Nodenms520JitterAlm | |||
| 1.3.6.1.4.1.498.8.2.4.30 | Nodenms520BpvAlm | |||
| 1.3.6.1.4.1.498.8.2.4.31 | Nodenms520FrameLossAlm | |||
| 1.3.6.1.4.1.498.8.2.4.32 | Nodenms520SignalToNoiseAlm | |||
| 1.3.6.1.4.1.498.8.2.4.33 | Nodenms520RxSignalLowAlm | |||
| 1.3.6.1.4.1.498.8.2.4.34 | Nodenms520ExtInputChangeAlm | |||
| 1.3.6.1.4.1.498.8.2.4.35 | Nodenms520ExtInputLowAlm | |||
| 1.3.6.1.4.1.498.8.2.5 | Tablenms520LineStatsTable | not-accessible | mandatory | The DDS Line Statistics table. |
| 1.3.6.1.4.1.498.8.2.5.1 | Rownms520LineStatsEntry | not-accessible | mandatory | An entry in the DDS Line Statistics Table. |
| 1.3.6.1.4.1.498.8.2.5.1.1 | Columnnms520LineStatsIndex | read-only | mandatory | |
| 1.3.6.1.4.1.498.8.2.5.1.2 | Columnnms520LineStatsInterval | read-only | mandatory | The DDS Line Statistics Interval. It specifies the amount of time in minutes (1 to 15 minutes) the unit will use to report statistical information. The unit wi… |
| 1.3.6.1.4.1.498.8.2.5.1.3 | Columnnms520LineStatsTxInterpretation | read-only | mandatory | This object will report the status of the line measurements, for the selected period. If noSignal(2), it will indicate that there is no receive signal availibl… |
| 1.3.6.1.4.1.498.8.2.5.1.4 | Columnnms520LineStatsTxLevel | read-only | mandatory | Will report the transmit Level of the line to be 0dB txLevel0dB(1), or 6dB txLevel6dB(2) as measured by the unit X minutes ago (1 to 15 miniutes) as specified … |
| 1.3.6.1.4.1.498.8.2.5.1.5 | Columnnms520LineStatsRxLevel | read-only | mandatory | This object will report the receive level measured at X minutes ago (1 to 15 miniutes) as specified by nms520LineStatsInterval. The range is between the -50dB … |
| 1.3.6.1.4.1.498.8.2.5.1.6 | Columnnms520LineStatsSignalToNoiseRatio | read-only | mandatory | This object will the report the signal to noise ratio measured X minutes ago(1 to 15 miniutes) as specified by nms520LineStatsInterval. The range is from 0 to … |
| 1.3.6.1.4.1.498.8.2.5.1.7 | Columnnms520LineStatsSignalQuality | read-only | mandatory | This object will the report the signal quality of the line measured X minutes ago (1 to 15 miniutes) as specified by nms520LineStatsInterval. |
| 1.3.6.1.4.1.498.8.2.5.1.8 | Columnnms520LineStatsJitter | read-only | mandatory | This object will the report the percent jitter of the line measured X minutes ago (1 to 15 miniutes) as specified by nms520LineStatsInterval. The range is 0% t… |
| 1.3.6.1.4.1.498.8.2.5.1.9 | Columnnms520LineStatsBpvCount | read-only | mandatory | This object will the report the number of bipolar violation that have occured over the last X minutes (1 to 15 minutes). The range is from 0 to 99 violations. |
| 1.3.6.1.4.1.498.8.2.5.1.10 | Columnnms520LineStatsFrameLossCount | read-only | mandatory | This object will the report the numbrt of frame losses that have occured over the last X minutes (1 to 15 minutes). The range is from 0 to 99 frame losses. |
| 1.3.6.1.4.1.498.8.2.6 | Tablenms520DiagCfgTable | not-accessible | mandatory | The NMS520 Unit Diagonostic table. |
| 1.3.6.1.4.1.498.8.2.6.1 | Rownms520DiagCfgEntry | not-accessible | mandatory | The NMS520 Unit Diagonostic table entry. |
| 1.3.6.1.4.1.498.8.2.6.1.1 | Columnnms520DiagCfgIndex | read-only | mandatory | The index value which uniquely identifies the NMS520 to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, and dro… |
| 1.3.6.1.4.1.498.8.2.6.1.2 | Columnnms520DiagSendCode | read-write | mandatory | Configures the selftest pattern to be run during any diagonostic test involving selftest. If option SendOtherPattern is selected, then pattern will default to … |
| 1.3.6.1.4.1.498.8.2.6.1.3 | Columnnms520DiagTestExceptions | read-only | mandatory | Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the valu… |
| 1.3.6.1.4.1.498.8.2.6.1.4 | Columnnms520DiagBitErrors | read-only | mandatory | The bit errors of the last diagnostic test that involved a Selftest pattern. Reading bit errors while a diagnostic test in running will cause the unit to drop … |
| 1.3.6.1.4.1.498.8.2.6.1.5 | Columnnms520DiagBlockErrors | read-only | mandatory | The block errors of the last diagnostic test that involved a Selftest pattern. Reading block errors while a diagnostic test in running will cause the unit to d… |
| 1.3.6.1.4.1.498.8.2.6.1.6 | Columnnms520DiagTestReset | read-write | mandatory | This object will halt the execution of any and all diagnostic test that may be running with the exception of the Network Delay Test. |
| 1.3.6.1.4.1.498.8.2.6.1.7 | Columnnms520DiagTimeDelay | read-only | mandatory | This object reads the results of a Network Delay Test. The results are valid only after the test is completed which takes about 10 seconds. The unit for time d… |
| 1.3.6.1.4.1.498.8.2.7 | Tablenms520DiagExcTable | not-accessible | mandatory | The NMS520 Unit Diagonostic table. |
| 1.3.6.1.4.1.498.8.2.7.1 | Rownms520DiagExcEntry | not-accessible | mandatory | The NMS520 Unit Diagonostic table entry. |
| 1.3.6.1.4.1.498.8.2.7.1.1 | Columnnms520DiagExcIndex | read-only | mandatory | The index value which uniquely identifies the NMS520 to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, and dro… |
| 1.3.6.1.4.1.498.8.2.7.1.2 | Columnnms520DiagExtLineloop | read-write | obsolete | Lineloop (or Analoop) can be either a Bilaterial or Unilaterial loopback depending on option ddsDteTermaloop. To initiate a Lineloop with no Selftest SET this … |
| 1.3.6.1.4.1.498.8.2.7.1.3 | Columnnms520DiagIntLineloop | read-write | mandatory | Lineloop (or Analoop) can be either a Bilaterial or Unilaterial loopback depending on option ddsDteTermaloop. To initiate a Lineloop with Selftest SET this obj… |
| 1.3.6.1.4.1.498.8.2.7.1.4 | Columnnms520DiagIntDataloop | read-write | mandatory | To initiate a Dataloop with Selftest SET this object and specifiy a blocksize. The nms520 (the remote) unit will go into Dataloop and the master (the sc5520) u… |
| 1.3.6.1.4.1.498.8.2.7.1.5 | Columnnms520DiagEndToEndSelftest | read-write | mandatory | To initiate an End to End Selftest(Error Rate Test) SET this object and specifiy a blocksize. Both the remote (nms520) amd master (sc5520) units will go into S… |
| 1.3.6.1.4.1.498.8.2.7.1.6 | Columnnms520DiagNetworkDelay | read-write | mandatory | To initiate a Network Delay test SET this object and specifiy runDelayTest. Both the remote (nms520) and master (sc5520) units will go into a test to measure n… |
| 1.3.6.1.4.1.498.8.2.7.1.7 | Columnnms520DiagTestStatus | read-only | mandatory | This object gives the current diagonostic test status. noTest indicates that no diagonostic test is currently active. Reading this object while in a diagonosti… |
| 1.3.6.1.4.1.498.8.2.7.1.8 | Columnnms520DiagExtDataloop | read-write | mandatory | To initiate a Dataloop test with no Selftest SET this object and specifiy external, this will allow the data from the DTE attached to the far end unit (sc5520)… |
| 1.3.6.1.4.1.498.8.2.8 | Tablenms520AlarmCfgTable | not-accessible | mandatory | The GDC NMS520 Alarm Configuration Table. |
| 1.3.6.1.4.1.498.8.2.8.1 | Rownms520AlarmCfgEntry | not-accessible | mandatory | An entry in the GDC NMS520 alarm Configuration table. |
| 1.3.6.1.4.1.498.8.2.8.1.1 | Columnnms520AlarmCfgIndex | read-only | mandatory | This object is the index of the NMS520 Alarm Threshold Configuration table. |
| 1.3.6.1.4.1.498.8.2.8.1.2 | Columnnms520AlarmCfgIdentifier | read-only | mandatory | The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do… |
| 1.3.6.1.4.1.498.8.2.8.1.3 | Columnnms520AlarmCfgThreshold | read-write | mandatory | This function sets/reads the alarm threashold settings criteria. This threshold is used along with the alarm window to determine the number of instances in a g… |