MIB Viewer

OMNI-gx2CEB-MIB

119 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.20.1Nodegx2CEBDescriptor
1.3.6.1.4.1.1166.6.1.2.20.1NodetrapCEBConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.20.2Tablegx2CEBAnalogTablenot-accessiblemandatoryThis table contains gx2CEB specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.20.2NodetrapCEBConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.20.2.1Rowgx2CEBAnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.20.2.1.1Columngx2CEBAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.20.2.1.2ColumnceblabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.3ColumncebuomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.4ColumncebmajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.20.2.1.5ColumncebmajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.6ColumncebminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.20.2.1.7ColumncebminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.8ColumncebcurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.20.2.1.9ColumncebstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.2.1.10ColumncebminValueModTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.11ColumncebmaxValueModTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.12ColumncebalarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.13ColumnceblabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.14ColumncebuomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.15ColumncebmajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.20.2.1.16ColumncebmajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.20.2.1.17ColumncebminorHighFanCurrentread-onlyobsoleteThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.20.2.1.18ColumncebminorLowFanCurrentread-onlyobsoleteThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.20.2.1.19ColumncebcurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.20.2.1.20ColumncebstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.2.1.21ColumncebminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.20.2.1.22ColumncebmaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.20.2.1.23ColumncebalarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.24ColumnceblabelAnalogVoltage01read-onlyoptionalThe value of this object provides the label of the Analog Voltage number 01 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.25ColumncebuomAnalogVoltage01read-onlyoptionalThe value of this object provides the Unit of Measure of the Analog Voltage number 01 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.26ColumncebmajorHighAnalogVoltage01read-onlymandatoryThe value of this object provides the Major High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.27ColumncebmajorLowAnalogVoltage01read-onlymandatoryThe value of this object provides the Major Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.28ColumncebminorHighAnalogVoltage01read-onlymandatoryThe value of this object provides the Minor High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.29ColumncebminorLowAnalogVoltage01read-onlymandatoryThe value of this object provides the Minor Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.30ColumncebcurrentValueAnalogVoltage01read-onlymandatoryThe value of this object provides the Current value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.20.2.1.31ColumncebstateFlagAnalogVoltage01read-onlymandatoryThe value of this object provides the state of the Analog Voltage number 01 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.2.1.32ColumncebminValueAnalogVoltage01read-onlymandatoryThe value of this object provides the minimum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.33ColumncebmaxValueAnalogVoltage01read-onlymandatoryThe value of this object provides the maximum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.34ColumncebalarmStateAnalogVoltage01read-onlymandatoryThe value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.35ColumnceblabelAnalogVoltage02read-onlyoptionalThe value of this object provides the label of the Analog Voltage number 02 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.36ColumncebuomAnalogVoltage02read-onlyoptionalThe value of this object provides the Unit of Measure of the Analog Voltage number 02 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.37ColumncebmajorHighAnalogVoltage02read-onlymandatoryThe value of this object provides the Major High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.38ColumncebmajorLowAnalogVoltage02read-onlymandatoryThe value of this object provides the Major Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.39ColumncebminorHighAnalogVoltage02read-onlymandatoryThe value of this object provides the Minor High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.40ColumncebminorLowAnalogVoltage02read-onlymandatoryThe value of this object provides the Minor Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.41ColumncebcurrentValueAnalogVoltage02read-onlymandatoryThe value of this object provides the Current value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.20.2.1.42ColumncebstateFlagAnalogVoltage02read-onlymandatoryThe value of this object provides the state of the Analog Voltage number 02 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.2.1.43ColumncebminValueAnalogVoltage02read-onlymandatoryThe value of this object provides the minimum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.44ColumncebmaxValueAnalogVoltage02read-onlymandatoryThe value of this object provides the maximum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.45ColumncebalarmStateAnalogVoltage02read-onlymandatoryThe value of this object provides the curent alarm state of the Analog Voltage number 02 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.46ColumnceblabelAnalogVoltage03read-onlyoptionalThe value of this object provides the label of the Analog Voltage number 03 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.47ColumncebuomAnalogVoltage03read-onlyoptionalThe value of this object provides the Unit of Measure of the Analog Voltage number 03 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.48ColumncebmajorHighAnalogVoltage03read-onlymandatoryThe value of this object provides the Major High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.49ColumncebmajorLowAnalogVoltage03read-onlymandatoryThe value of this object provides the Major Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.50ColumncebminorHighAnalogVoltage03read-onlymandatoryThe value of this object provides the Minor High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.51ColumncebminorLowAnalogVoltage03read-onlymandatoryThe value of this object provides the Minor Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.52ColumncebcurrentValueAnalogVoltage03read-onlymandatoryThe value of this object provides the Current value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.20.2.1.53ColumncebstateFlagAnalogVoltage03read-onlymandatoryThe value of this object provides the state of the Analog Voltage number 03 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.2.1.54ColumncebminValueAnalogVoltage03read-onlymandatoryThe value of this object provides the minimum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.55ColumncebmaxValueAnalogVoltage03read-onlymandatoryThe value of this object provides the maximum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.56ColumncebalarmStateAnalogVoltage03read-onlymandatoryThe value of this object provides the curent alarm state of the Analog Voltage number 03 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.57ColumnceblabelAnalogVoltage04read-onlyoptionalThe value of this object provides the label of the Analog Voltage number 04 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.58ColumncebuomAnalogVoltage04read-onlyoptionalThe value of this object provides the Unit of Measure of the Analog Voltage number 04 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.59ColumncebmajorHighAnalogVoltage04read-onlymandatoryThe value of this object provides the Major High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.60ColumncebmajorLowAnalogVoltage04read-onlymandatoryThe value of this object provides the Major Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.61ColumncebminorHighAnalogVoltage04read-onlymandatoryThe value of this object provides the Minor High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.62ColumncebminorLowAnalogVoltage04read-onlymandatoryThe value of this object provides the Minor Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.63ColumncebcurrentValueAnalogVoltage04read-onlymandatoryThe value of this object provides the Current value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.20.2.1.64ColumncebstateFlagAnalogVoltage04read-onlymandatoryThe value of this object provides the state of the Analog Voltage number 04 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.2.1.65ColumncebminValueAnalogVoltage04read-onlymandatoryThe value of this object provides the minimum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.66ColumncebmaxValueAnalogVoltage04read-onlymandatoryThe value of this object provides the maximum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.67ColumncebalarmStateAnalogVoltage04read-onlymandatoryThe value of this object provides the curent alarm state of the Analog Voltage number 04 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.68ColumnceblabelAnalogVoltage05read-onlyoptionalThe value of this object provides the label of the Analog Voltage number 05 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.69ColumncebuomAnalogVoltage05read-onlyoptionalThe value of this object provides the Unit of Measure of the Analog Voltage number 05 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.2.1.70ColumncebmajorHighAnalogVoltage05read-onlymandatoryThe value of this object provides the Major High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.71ColumncebmajorLowAnalogVoltage05read-onlymandatoryThe value of this object provides the Major Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.72ColumncebminorHighAnalogVoltage05read-onlymandatoryThe value of this object provides the Minor High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.20.2.1.73ColumncebminorLowAnalogVoltage05read-onlymandatoryThe value of this object provides the Minor Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.20.2.1.74ColumncebcurrentValueAnalogVoltage05read-onlymandatoryThe value of this object provides the Current value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.20.2.1.75ColumncebstateFlagAnalogVoltage05read-onlymandatoryThe value of this object provides the state of the Analog Voltage number 05 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.2.1.76ColumncebminValueAnalogVoltage05read-onlymandatoryThe value of this object provides the minimum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.77ColumncebmaxValueAnalogVoltage05read-onlymandatoryThe value of this object provides the maximum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is rep…
1.3.6.1.4.1.1166.6.1.2.20.2.1.78ColumncebalarmStateAnalogVoltage05read-onlymandatoryThe value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter.
1.3.6.1.4.1.1166.6.1.2.20.3Tablegx2CEBStatusTablenot-accessiblemandatoryThis table contains gx2CEB specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.20.3NodetrapCEBfanCurrentAlarmThis trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.20.3.2Rowgx2CEBStatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.20.3.2.1Columngx2CEBStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.20.3.2.2ColumnceblabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.20.3.2.3ColumncebvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.20.3.2.4ColumncebstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.3.2.5ColumnceblabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.20.3.2.6ColumncebvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.20.3.2.7ColumncebstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.3.2.8ColumnceblabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.20.3.2.9ColumncebvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.20.3.2.10ColumncebstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.3.2.11ColumnceblabelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.20.3.2.12ColumncebvalueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.20.3.2.13ColumncebstateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.20.4Tablegx2CEBFactoryTablenot-accessiblemandatoryThis table contains gx2CEB specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.20.4NodetrapCEBModuleTempAlarmThis trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.20.4.3Rowgx2CEBFactoryEntrynot-accessiblemandatoryThis list contains Factory parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.20.4.3.1Columngx2CEBFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.20.4.3.2ColumncebbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.20.4.3.3ColumncebbootStatusByteread-onlymandatoryThis object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 =…
1.3.6.1.4.1.1166.6.1.2.20.4.3.4Columncebbank1CRCread-onlymandatoryThis object provides the CRC code of bank 0. The display formate for the data is Hex.
1.3.6.1.4.1.1166.6.1.2.20.4.3.5Columncebbank2CRCread-onlymandatoryThis object provides the CRC code of bank 1.The display formate for the data is Hex.
1.3.6.1.4.1.1166.6.1.2.20.4.3.6ColumncebprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.20.4.3.7ColumncebfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.20.4.3.8ColumncebcalculateCRCread-onlyobsoleteThis object indicates which of the Enums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.20.4.3.9ColumncebhourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.20.4.3.10ColumncebflashPrgCntAread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.20.4.3.11ColumncebflashPrgCntBread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.20.4.3.12ColumncebflashBankARevread-onlymandatoryThis object provides the revision of flash bank 0. The rev is 2 characters.
1.3.6.1.4.1.1166.6.1.2.20.4.3.13ColumncebflashBankBRevread-onlymandatoryThis object provides the revision of flash bank 1. The rev is 2 characters.
1.3.6.1.4.1.1166.6.1.2.20.5NodetrapCEBFlashAlarmThis trap is issued when the Laser Modules detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.20.6NodetrapCEBBankBootAlarmThis trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.20.7NodetrapCEBAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.20.8NodetrapCEBFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.