MIB Viewer

OMNI-gx2DM2000-MIB

219 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.34.1Nodegx2dm2000Descriptor
1.3.6.1.4.1.1166.6.1.2.34.1NodetrapDM2000ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.34.2Tablegx2dm2000AnalogTablenot-accessiblemandatoryThis table contains gx2Dm2000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.34.2NodetrapDM2000ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.34.2.1Rowgx2dm2000AnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.34.2.1.1Columngx2dm2000AnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.34.2.1.2Columndm2000labelOffsetNomMonitorread-onlyoptionalThe value of this object provides the label of the Offset Monitor Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.3Columndm2000uomOffsetNomMonitorread-onlyoptionalThe value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.4Columndm2000majorHighOffsetNomMonitorread-onlymandatoryThe value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.34.2.1.5Columndm2000majorLowOffsetNomMonitorread-onlymandatoryThe value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.6Columndm2000minorHighOffsetNomMonitorread-onlymandatoryThe value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit…
1.3.6.1.4.1.1166.6.1.2.34.2.1.7Columndm2000minorLowOffsetNomMonitorread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit …
1.3.6.1.4.1.1166.6.1.2.34.2.1.8Columndm2000currentValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
1.3.6.1.4.1.1166.6.1.2.34.2.1.9Columndm2000stateFlagOffsetNomMonitorread-onlymandatoryThe value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
1.3.6.1.4.1.1166.6.1.2.34.2.1.10Columndm2000minValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit …
1.3.6.1.4.1.1166.6.1.2.34.2.1.11Columndm2000maxValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit …
1.3.6.1.4.1.1166.6.1.2.34.2.1.12Columndm2000alarmStateOffsetNomMonitorread-onlymandatoryThe value of this object provides the curent alarm state of the Offset Monitor Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.13Columndm2000labelOffsetNomCntread-onlyoptionalThe value of this object provides the label of the Offset Control Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.14Columndm2000uomOffsetNomCntread-onlyoptionalThe value of this object provides the label of the Offset Control Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.15Columndm2000majorHighOffsetNomCntread-onlymandatoryThe value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit…
1.3.6.1.4.1.1166.6.1.2.34.2.1.16Columndm2000majorLowOffsetNomCntread-onlymandatoryThe value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit …
1.3.6.1.4.1.1166.6.1.2.34.2.1.17Columndm2000minorHighOffsetNomCntread-onlymandatoryThe value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.34.2.1.18Columndm2000minorLowOffsetNomCntread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.19Columndm2000currentValueOffsetNomCntread-writemandatoryThe value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEE…
1.3.6.1.4.1.1166.6.1.2.34.2.1.20Columndm2000stateFlagOffsetNomCntread-onlymandatoryThe value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
1.3.6.1.4.1.1166.6.1.2.34.2.1.21Columndm2000minValueOffsetNomCntread-onlymandatoryThe value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.22Columndm2000maxValueOffsetNomCntread-onlymandatoryThe value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.23Columndm2000alarmStateOffsetNomCntread-onlymandatoryThe value of this object provides the curent alarm state of the Offset Control Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.24Columndm2000labelRelAttenSettingread-onlyoptionalThe value of this object provides the label of the Attenuator Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.25Columndm2000uomRelAttenSettingread-onlyoptionalThe value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.26Columndm2000majorHighRelAttenSettingread-onlymandatoryThe value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.34.2.1.27Columndm2000majorLowRelAttenSettingread-onlymandatoryThe value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.28Columndm2000minorHighRelAttenSettingread-onlymandatoryThe value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.34.2.1.29Columndm2000minorLowRelAttenSettingread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.30Columndm2000currentValueRelAttenSettingread-writemandatoryThe value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.34.2.1.31Columndm2000stateFlagRelAttenSettingread-onlymandatoryThe value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.2.1.32Columndm2000minValueRelAttenSettingread-onlymandatoryThe value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.33Columndm2000maxValueRelAttenSettingread-onlymandatoryThe value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.34Columndm2000alarmStateRelAttenSettingread-onlymandatoryThe value of this object provides the curent alarm state of the Attenuator Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.35Columndm2000labelOptPowerread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.36Columndm2000uomOptPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.37Columndm2000majorHighOptPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.38Columndm2000majorLowOptPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.34.2.1.39Columndm2000minorHighOptPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.40Columndm2000minorLowOptPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.34.2.1.41Columndm2000currentValueOptPowerread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.34.2.1.42Columndm2000stateFlagOptPowerread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.2.1.43Columndm2000minValueOptPowerread-onlymandatoryThe value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.34.2.1.44Columndm2000maxValueOptPowerread-onlymandatoryThe value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.34.2.1.45Columndm2000alarmStateOptPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.46Columndm2000labelLaserBiasread-onlyoptionalThe value of this object provides the label of the Laser Bias Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.47Columndm2000uomLaserBiasread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Bias Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.48Columndm2000majorHighLaserBiasread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.49Columndm2000majorLowLaserBiasread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.34.2.1.50Columndm2000minorHighLaserBiasread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.51Columndm2000minorLowLaserBiasread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.34.2.1.52Columndm2000currentValueLaserBiasread-onlymandatoryThe value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32…
1.3.6.1.4.1.1166.6.1.2.34.2.1.53Columndm2000stateFlagLaserBiasread-onlymandatoryThe value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.2.1.54Columndm2000minValueLaserBiasread-onlymandatoryThe value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.34.2.1.55Columndm2000maxValueLaserBiasread-onlymandatoryThe value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.34.2.1.56Columndm2000alarmStateLaserBiasread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Bias Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.57Columndm2000labelTecCurrentread-onlyoptionalThe value of this object provides the label of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.58Columndm2000uomTecCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the TEC Current Analog parameter..
1.3.6.1.4.1.1166.6.1.2.34.2.1.59Columndm2000majorHighTecCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.34.2.1.60Columndm2000majorLowTecCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.61Columndm2000minorHighTecCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.34.2.1.62Columndm2000minorLowTecCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.63Columndm2000currentValueTecCurrentread-onlymandatoryThe value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.34.2.1.64Columndm2000stateFlagTecCurrentread-onlymandatoryThe value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.2.1.65Columndm2000minValueTecCurrentread-onlymandatoryThe value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.66Columndm2000maxValueTecCurrentread-onlymandatoryThe value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.67Columndm2000alarmStateTecCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.68Columndm2000labelLaserTempread-onlyoptionalThe value of this object provides the label of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.69Columndm2000uomLaserTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.70Columndm2000majorHighLaserTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.71Columndm2000majorLowLaserTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.34.2.1.72Columndm2000minorHighLaserTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.73Columndm2000minorLowLaserTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.34.2.1.74Columndm2000currentValueLaserTempread-onlymandatoryThe value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.34.2.1.75Columndm2000stateFlagLaserTempread-onlymandatoryThe value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.2.1.76Columndm2000minValueLaserTempread-onlymandatoryThe value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.34.2.1.77Columndm2000maxValueLaserTempread-onlymandatoryThe value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.34.2.1.78Columndm2000alarmStateLaserTempread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.79Columndm2000labelModuleTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.80Columndm2000uomModuleTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.81Columndm2000majorHighModuleTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.34.2.1.82Columndm2000majorLowModuleTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.83Columndm2000minorHighModuleTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.34.2.1.84Columndm2000minorLowModuleTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.85Columndm2000currentValueModuleTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.34.2.1.86Columndm2000stateFlagModuleTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.2.1.87Columndm2000minValueModuleTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.88Columndm2000maxValueModuleTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.34.2.1.89Columndm2000alarmStateModuleTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.90Columndm2000labelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.91Columndm2000uomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.92Columndm2000majorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.34.2.1.93Columndm2000majorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.94Columndm2000minorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.34.2.1.95Columndm2000minorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.96Columndm2000currentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.34.2.1.97Columndm2000stateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.2.1.98Columndm2000minValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.99Columndm2000maxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.100Columndm2000alarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.101Columndm2000label12Voltread-onlyoptionalThe value of this object provides the label of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.102Columndm2000uom12Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.2.1.103Columndm2000majorHigh12Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.34.2.1.104Columndm2000majorLow12Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.105Columndm2000minorHigh12Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.34.2.1.106Columndm2000minorLow12Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.107Columndm2000currentValue12Voltread-onlymandatoryThe value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.34.2.1.108Columndm2000stateFlag12Voltread-onlymandatoryThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.2.1.109Columndm2000minValue12Voltread-onlymandatoryThe value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.110Columndm2000maxValue12Voltread-onlymandatoryThe value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.34.2.1.111Columndm2000alarmState12Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.34.3Tablegx2dm2000DigitalTablenot-accessiblemandatoryThis table contains gx2Dm2000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.34.3NodetrapDM2000RFInputAlarmThis trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame…
1.3.6.1.4.1.1166.6.1.2.34.3.2Rowgx2dm2000DigitalEntrynot-accessiblemandatoryThis list contains digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.34.3.2.1Columngx2dm2000DigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.34.3.2.2Columndm2000labelRfInputread-onlyoptionalThe value of this object provides the label of the RF Input Control Digital parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.3Columndm2000enumRfInputread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.34.3.2.4Columndm2000valueRfInputread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.5Columndm2000stateflagRfInputread-onlymandatoryThe value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.3.2.6Columndm2000labelOptOutputread-onlyoptionalThe value of this object provides the label of the Optical Output Control Digital parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.7Columndm2000enumOptOutputread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.34.3.2.8Columndm2000valueOptOutputread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.9Columndm2000stateflagOptOutputread-onlymandatoryThe value of this object provides the dm2000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.3.2.10Columndm2000labelLaserModeread-onlyoptionalThe value of this object provides the label of the Laser Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.11Columndm2000enumLaserModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.34.3.2.12Columndm2000valueLaserModeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.13Columndm2000stateflagLaserModeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.3.2.14Columndm2000labelLaserSecModeread-onlyoptionalThe value of this object provides the label of the Laser Secondary Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.15Columndm2000enumLaserSecModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.34.3.2.16Columndm2000valueLaserSecModeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.17Columndm2000stateflagLaserSecModeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.3.2.18Columndm2000labelVideoOffsetread-onlyoptionalThe value of this object provides the label of the Video Offset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.19Columndm2000enumVideoOffsetread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.34.3.2.20Columndm2000valueVideoOffsetread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.21Columndm2000stateflagVideoOffsetread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.3.2.22Columndm2000labelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.23Columndm2000enumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.34.3.2.24Columndm2000valueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.25Columndm2000stateflagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.3.2.26Columndm2000labelFiberLengthread-onlyoptionalThe value of this object provides the label for the Fiber Length Digital parameter .
1.3.6.1.4.1.1166.6.1.2.34.3.2.27Columndm2000enumFiberLengthread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. The range for fiber length selection is from 0 to 60km, where 0k…
1.3.6.1.4.1.1166.6.1.2.34.3.2.28Columndm2000valueFiberLengthread-writemandatoryThe value of this object is the current value of the parameter. It is used to set fiber length. The value range for this object is: 1 to 61. Where 1 = 0Km and …
1.3.6.1.4.1.1166.6.1.2.34.3.2.29Columndm2000stateflagFiberLengthread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.3.2.30Columndm2000labelWavelengthOffsetread-onlyoptionalThe value of this object provides the label for the Wavelength Offset Digital parameter .
1.3.6.1.4.1.1166.6.1.2.34.3.2.31Columndm2000enumWavelengthOffsetread-onlyoptionalThe value of this object represents the Enumeration values possible for this Digital parameter.
1.3.6.1.4.1.1166.6.1.2.34.3.2.32Columndm2000valueWavelengthOffsetread-writemandatoryThe value of this object is the current value of the parameter. It is used to select a Narrowcast or Full Spectrum application.
1.3.6.1.4.1.1166.6.1.2.34.3.2.33Columndm2000stateflagWavelengthOffsetread-onlymandatoryThe value of this object provides the state of the the Wavelength Offset parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.4Tablegx2dm2000StatusTablenot-accessiblemandatoryThis table contains gx2Dm2000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.34.4NodetrapDM2000RFOverloadAlarmThis trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par…
1.3.6.1.4.1.1166.6.1.2.34.4.3Rowgx2dm2000StatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.34.4.3.1Columngx2dm2000StatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.34.4.3.2Columndm2000labelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.34.4.3.3Columndm2000valueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.34.4.3.4Columndm2000stateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.4.3.5Columndm2000labelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.34.4.3.6Columndm2000valueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.34.4.3.7Columndm2000stateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.4.3.8Columndm2000labelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.34.4.3.9Columndm2000valueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.34.4.3.10Columndm2000stateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.4.3.11Columndm2000labelLaserDataCRCread-onlyoptionalThe value of this object provides the label of the Laser Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.34.4.3.12Columndm2000valueLaserDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.34.4.3.13Columndm2000stateflagLaserDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.4.3.14Columndm2000labelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.34.4.3.15Columndm2000valueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.34.4.3.16Columndm2000stateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.4.3.17Columndm2000labelHWStatusread-onlyoptionalThe value of this object provides the label of the Laser Drive Level Status parameter.
1.3.6.1.4.1.1166.6.1.2.34.4.3.18Columndm2000valueHWStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.34.4.3.19Columndm2000stateflagHWStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.4.3.20Columndm2000labelRFInputStatusread-onlyoptionalThe value of this object provides the label of the RF Input Status parameter.
1.3.6.1.4.1.1166.6.1.2.34.4.3.21Columndm2000valueRFInputStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.34.4.3.22Columndm2000stateflagRFInputStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.34.5Tablegx2dm2000FactoryTablenot-accessiblemandatoryThis table contains gx2Dm2000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.34.5NodetrapDM2000RFOffsetAlarmThis trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this param…
1.3.6.1.4.1.1166.6.1.2.34.5.4Rowgx2dm2000FactoryEntrynot-accessiblemandatoryThis list contains Factory parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.34.5.4.1Columngx2dm2000FactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.34.5.4.2Columndm2000bootControlByteValueread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.34.5.4.3Columndm2000bootStatusByteValueread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.34.5.4.4Columndm2000bank1CRCValueread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.34.5.4.5Columndm2000bank2CRCValueread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.34.5.4.6Columndm2000prgEEPROMByteValueread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.34.5.4.7Columndm2000factoryCRCValueread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.34.5.4.8Columndm2000calculateCRCValueread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.34.5.4.9Columndm2000hourMeterValueread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.34.5.4.10Columndm2000flashPrgCntAValueread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.34.5.4.11Columndm2000flashPrgCntBValueread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.34.5.4.12Columndm2000flashBankARevValueread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.34.5.4.13Columndm2000flashBankBRevValueread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.34.6Tablegx2Dm2000HoldTimeTablenot-accessiblemandatoryThis table contains gx2Dm2000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.34.6NodetrapDM2000OpticalPowerAlarmThis trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this p…
1.3.6.1.4.1.1166.6.1.2.34.6.5Rowgx2Dm2000HoldTimeEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.34.6.5.1Columngx2Dm2000HoldTimeTableIndexread-onlymandatoryThe value of this object is the index of the data object.
1.3.6.1.4.1.1166.6.1.2.34.6.5.2Columngx2Dm2000HoldTimeSpecIndexread-onlymandatoryThe value of this object identifies the index of the alarm object to be modified.
1.3.6.1.4.1.1166.6.1.2.34.6.5.3Columngx2Dm2000HoldTimeDataread-writemandatoryThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered…
1.3.6.1.4.1.1166.6.1.2.34.7NodetrapDM2000LaserBiasAlarmThis trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.34.8NodetrapDM2000LaserTempAlarmThis trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.34.9NodetrapDM2000TECCurrentAlarmThis trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par…
1.3.6.1.4.1.1166.6.1.2.34.10NodetrapDM2000FanCurrentAlarmThis trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par…
1.3.6.1.4.1.1166.6.1.2.34.11NodetrapDM200012vAlarmThis trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this paramet…
1.3.6.1.4.1.1166.6.1.2.34.12NodetrapDM2000ModuleTempAlarmThis trap is issued when the Laser Module Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.34.13NodetrapDM2000FlashAlarmThis trap is issued when the Laser Modules detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.34.14NodetrapDM2000LaserBiasCntLoopAlarmThis trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation.
1.3.6.1.4.1.1166.6.1.2.34.15NodetrapDM2000BankBootAlarmThis trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.34.16NodetrapDM2000LaserBiasCntLoopInitAlarmThis trap is issued when the Laser Bias Control loop init fails.
1.3.6.1.4.1.1166.6.1.2.34.17NodetrapDM2000RFParamInitAlarmThis trap is issued when the RF parameter Init fails.
1.3.6.1.4.1.1166.6.1.2.34.18NodetrapDM2000TECParamInitAlarmThis trap is issued when the TEC Parameter Init fails.
1.3.6.1.4.1.1166.6.1.2.34.19NodetrapDM2000AttnTableInitAlarmThis trap is issued when the Attenuator Table Init fails.
1.3.6.1.4.1.1166.6.1.2.34.20NodetrapDM2000PowerMeterTableInitAlarmThis trap is issued when the Power Meter Table Init fails.
1.3.6.1.4.1.1166.6.1.2.34.21NodetrapDM2000LaserDataCRCAlarmThis trap is issued when the Laser Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.34.22NodetrapDM2000AlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.34.23NodetrapDM2000FactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.34.24NodetrapDM2000UserRFOffAlarmThis trap is issued when the the User RF is turned off.
1.3.6.1.4.1.1166.6.1.2.34.25NodetrapDM2000UserOpticalOffAlarmThis trap is issued when the User Optical Power is turned off.
1.3.6.1.4.1.1166.6.1.2.34.26NodetrapDM2000ResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.