OMNI-gx2EA1000-MIB
208 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.33.1 | Nodegx2ea1000Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.33.1 | NodetrapEA1000ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.2 | Tablegx2ea1000AnalogTable | not-accessible | mandatory | This table contains gx2Ea1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.33.2 | NodetrapEA1000ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.33.2.1 | Rowgx2ea1000AnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.1 | Columngx2ea1000AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.2 | Columnea1000labelOffsetNomMonitor | read-only | optional | The value of this object provides the label of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.3 | Columnea1000uomOffsetNomMonitor | read-only | optional | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.4 | Columnea1000majorHighOffsetNomMonitor | read-only | mandatory | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.5 | Columnea1000majorLowOffsetNomMonitor | read-only | mandatory | The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.6 | Columnea1000minorHighOffsetNomMonitor | read-only | mandatory | The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.7 | Columnea1000minorLowOffsetNomMonitor | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.8 | Columnea1000currentValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.9 | Columnea1000stateFlagOffsetNomMonitor | read-only | mandatory | The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.10 | Columnea1000minValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.11 | Columnea1000maxValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.12 | Columnea1000alarmStateOffsetNomMonitor | read-only | mandatory | The value of this object provides the curent alarm state of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.13 | Columnea1000labelOffsetNomCnt | read-only | optional | The value of this object provides the label of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.14 | Columnea1000uomOffsetNomCnt | read-only | optional | The value of this object provides the label of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.15 | Columnea1000majorHighOffsetNomCnt | read-only | optional | The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.16 | Columnea1000majorLowOffsetNomCnt | read-only | optional | The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.17 | Columnea1000minorHighOffsetNomCnt | read-only | optional | The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.18 | Columnea1000minorLowOffsetNomCnt | read-only | optional | The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.19 | Columnea1000currentValueOffsetNomCnt | read-write | mandatory | The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEE… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.20 | Columnea1000stateFlagOffsetNomCnt | read-only | mandatory | The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.21 | Columnea1000minValueOffsetNomCnt | read-only | mandatory | The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.22 | Columnea1000maxValueOffsetNomCnt | read-only | mandatory | The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.23 | Columnea1000alarmStateOffsetNomCnt | read-only | mandatory | The value of this object provides the curent alarm state of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.24 | Columnea1000labelOptPower | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.25 | Columnea1000uomOptPower | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.26 | Columnea1000majorHighOptPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.27 | Columnea1000majorLowOptPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.28 | Columnea1000minorHighOptPower | read-only | optional | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.29 | Columnea1000minorLowOptPower | read-only | optional | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.30 | Columnea1000currentValueOptPower | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.31 | Columnea1000stateFlagOptPower | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.32 | Columnea1000minValueOptPower | read-only | mandatory | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.33 | Columnea1000maxValueOptPower | read-only | mandatory | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.34 | Columnea1000alarmStateOptPower | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.35 | Columnea1000labelLaserTemp | read-only | optional | The value of this object provides the label of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.36 | Columnea1000uomLaserTemp | read-only | optional | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.37 | Columnea1000majorHighLaserTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.38 | Columnea1000majorLowLaserTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.39 | Columnea1000minorHighLaserTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.40 | Columnea1000minorLowLaserTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.41 | Columnea1000currentValueLaserTemp | read-only | mandatory | The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.42 | Columnea1000stateFlagLaserTemp | read-only | mandatory | The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.43 | Columnea1000minValueLaserTemp | read-only | mandatory | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.44 | Columnea1000maxValueLaserTemp | read-only | mandatory | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.45 | Columnea1000alarmStateLaserTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.46 | Columnea1000labelLaserBias | read-only | optional | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.47 | Columnea1000uomLaserBias | read-only | optional | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.48 | Columnea1000majorHighLaserBias | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.49 | Columnea1000majorLowLaserBias | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.50 | Columnea1000minorHighLaserBias | read-only | optional | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.51 | Columnea1000minorLowLaserBias | read-only | optional | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.52 | Columnea1000currentValueLaserBias | read-only | mandatory | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.53 | Columnea1000stateFlagLaserBias | read-only | mandatory | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.54 | Columnea1000minValueLaserBias | read-only | mandatory | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.55 | Columnea1000maxValueLaserBias | read-only | mandatory | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.56 | Columnea1000alarmStateLaserBias | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.57 | Columnea1000labelTecCurrent | read-only | optional | The value of this object provides the label of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.58 | Columnea1000uomTecCurrent | read-only | optional | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.59 | Columnea1000majorHighTecCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.60 | Columnea1000majorLowTecCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.61 | Columnea1000minorHighTecCurrent | read-only | optional | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.62 | Columnea1000minorLowTecCurrent | read-only | optional | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.63 | Columnea1000currentValueTecCurrent | read-only | mandatory | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.64 | Columnea1000stateFlagTecCurrent | read-only | mandatory | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.65 | Columnea1000minValueTecCurrent | read-only | mandatory | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.66 | Columnea1000maxValueTecCurrent | read-only | mandatory | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.67 | Columnea1000alarmStateTecCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.68 | Columnea1000labelModuleTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.69 | Columnea1000uomModuleTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.70 | Columnea1000majorHighModuleTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.71 | Columnea1000majorLowModuleTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.72 | Columnea1000minorHighModuleTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.73 | Columnea1000minorLowModuleTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.74 | Columnea1000currentValueModuleTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.75 | Columnea1000stateFlagModuleTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.76 | Columnea1000minValueModuleTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.77 | Columnea1000maxValueModuleTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.78 | Columnea1000alarmStateModuleTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.79 | Columnea1000labelFan1Speed | read-only | optional | The value of this object provides the label of the Fan 1 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.80 | Columnea1000uomFan1Speed | read-only | optional | The value of this object provides the Unit of Measure of the Fan 1 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.81 | Columnea1000majorHighFan1Speed | read-only | optional | The value of this object provides the Major High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.82 | Columnea1000majorLowFan1Speed | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.83 | Columnea1000minorHighFan1Speed | read-only | optional | The value of this object provides the Minor High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.84 | Columnea1000minorLowFan1Speed | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.85 | Columnea1000currentValueFan1Speed | read-only | mandatory | The value of this object provides the Current value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.86 | Columnea1000stateFlagFan1Speed | read-only | mandatory | The value of this object provides the state of the Fan 1 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.87 | Columnea1000minValueFan1Speed | read-only | mandatory | The value of this object provides the minimum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.88 | Columnea1000maxValueFan1Speed | read-only | mandatory | The value of this object provides the maximum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.89 | Columnea1000alarmStateFan1Speed | read-only | mandatory | The value of this object provides the curent alarm state of the Fan 1 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.90 | Columnea1000labelFan2Speed | read-only | optional | The value of this object provides the label of the Fan 2 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.91 | Columnea1000uomFan2Speed | read-only | optional | The value of this object provides the Unit of Measure of the Fan 2 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.92 | Columnea1000majorHighFan2Speed | read-only | optional | The value of this object provides the Major High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.93 | Columnea1000majorLowFan2Speed | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.94 | Columnea1000minorHighFan2Speed | read-only | optional | The value of this object provides the Minor High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.95 | Columnea1000minorLowFan2Speed | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.96 | Columnea1000currentValueFan2Speed | read-only | mandatory | The value of this object provides the Current value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.97 | Columnea1000stateFlagFan2Speed | read-only | mandatory | The value of this object provides the state of the Fan 2 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.98 | Columnea1000minValueFan2Speed | read-only | mandatory | The value of this object provides the minimum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.99 | Columnea1000maxValueFan2Speed | read-only | mandatory | The value of this object provides the maximum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.100 | Columnea1000alarmStateFan2Speed | read-only | mandatory | The value of this object provides the curent alarm state of the Fan 2 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.101 | Columnea1000label12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.102 | Columnea1000uom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.103 | Columnea1000majorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.104 | Columnea1000majorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.105 | Columnea1000minorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.106 | Columnea1000minorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.107 | Columnea1000currentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.108 | Columnea1000stateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.109 | Columnea1000minValue12Volt | read-only | mandatory | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.110 | Columnea1000maxValue12Volt | read-only | mandatory | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.33.2.1.111 | Columnea1000alarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3 | Tablegx2ea1000DigitalTable | not-accessible | mandatory | This table contains gx2Ea1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.33.3 | NodetrapEA1000RFInputAlarm | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.3.2 | Rowgx2ea1000DigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.1 | Columngx2ea1000DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.2 | Columnea1000labelRfInput | read-only | optional | The value of this object provides the label of the RF Input Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.3 | Columnea1000enumRfInput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.4 | Columnea1000valueRfInput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.5 | Columnea1000stateflagRfInput | read-only | mandatory | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.6 | Columnea1000labelOptOutput | read-only | optional | The value of this object provides the label of the Optical Output Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.7 | Columnea1000enumOptOutput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.8 | Columnea1000valueOptOutput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.9 | Columnea1000stateflagOptOutput | read-only | mandatory | The value of this object provides the ea1000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.10 | Columnea1000labelLaserMode | read-only | optional | The value of this object provides the label of the Laser Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.11 | Columnea1000enumLaserMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.12 | Columnea1000valueLaserMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.13 | Columnea1000stateflagLaserMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.14 | Columnea1000labelAttenSetting | read-only | optional | The value of this object provides the label of the Attenuation Setting Ditital Parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.15 | Columnea1000enumAttenSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.16 | Columnea1000valueAttenSetting | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.17 | Columnea1000stateflagAttenSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.18 | Columnea1000labelLaserSecMode | read-only | optional | The value of this object provides the label of the Laser Secondary Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.19 | Columnea1000enumLaserSecMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.20 | Columnea1000valueLaserSecMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.21 | Columnea1000stateflagLaserSecMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.22 | Columnea1000labelVideoOffset | read-only | optional | The value of this object provides the label of the Video Offset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.23 | Columnea1000enumVideoOffset | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.24 | Columnea1000valueVideoOffset | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.25 | Columnea1000stateflagVideoOffset | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.26 | Columnea1000labelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.27 | Columnea1000enumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.28 | Columnea1000valueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.3.2.29 | Columnea1000stateflagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.4 | Tablegx2ea1000StatusTable | not-accessible | mandatory | This table contains gx2Ea1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.33.4 | NodetrapEA1000RFOverloadAlarm | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.4.3 | Rowgx2ea1000StatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.1 | Columngx2ea1000StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.2 | Columnea1000labelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.3 | Columnea1000valueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.4 | Columnea1000stateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.5 | Columnea1000labelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.6 | Columnea1000valueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.7 | Columnea1000stateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.8 | Columnea1000labelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.9 | Columnea1000valueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.10 | Columnea1000stateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.11 | Columnea1000labelLaserDataCRC | read-only | optional | The value of this object provides the label of the Laser Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.12 | Columnea1000valueLaserDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.13 | Columnea1000stateflagLaserDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.14 | Columnea1000labelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.15 | Columnea1000valueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.16 | Columnea1000stateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.17 | Columnea1000labelRFInputStatus | read-only | optional | The value of this object provides the label of the RF Input Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.18 | Columnea1000valueRFInputStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.33.4.3.19 | Columnea1000stateflagRFInputStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.33.5 | Tablegx2ea1000FactoryTable | not-accessible | mandatory | This table contains gx2Ea1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.33.5 | NodetrapEA1000RFOffsetAlarm | This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this param… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.5.4 | Rowgx2ea1000FactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.1 | Columngx2ea1000FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.2 | Columnea1000bootControlByteValue | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.3 | Columnea1000bootStatusByteValue | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.4 | Columnea1000bank1CRCValue | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.5 | Columnea1000bank2CRCValue | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.6 | Columnea1000prgEEPROMByteValue | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.7 | Columnea1000factoryCRCValue | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.8 | Columnea1000calculateCRCValue | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.9 | Columnea1000hourMeterValue | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.10 | Columnea1000flashPrgCntAValue | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.11 | Columnea1000flashPrgCntBValue | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.12 | Columnea1000flashBankARevValue | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.33.5.4.13 | Columnea1000flashBankBRevValue | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.33.6 | NodetrapEA1000OpticalPowerAlarm | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this p… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.7 | NodetrapEA1000LaserBiasAlarm | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.8 | NodetrapEA1000LaserTempAlarm | This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.9 | NodetrapEA1000TECCurrentAlarm | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.10 | NodetrapEA1000Fan1SpeedAlarm | This trap is issued when the Laser Modules Fan 1 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.11 | NodetrapEA1000Fan2SpeedAlarm | This trap is issued when the Laser Modules Fan 2 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.12 | NodetrapEA100012vAlarm | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this paramet… | ||
| 1.3.6.1.4.1.1166.6.1.2.33.13 | NodetrapEA1000ModuleTempAlarm | This trap is issued when the Laser Module Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.14 | NodetrapEA1000FlashAlarm | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.15 | NodetrapEA1000LaserBiasCntLoopAlarm | This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.16 | NodetrapEA1000BankBootAlarm | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.17 | NodetrapEA1000LaserBiasCntLoopInitAlarm | This trap is issued when the Laser Bias Control loop init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.18 | NodetrapEA1000RFParamInitAlarm | This trap is issued when the RF parameter Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.19 | NodetrapEA1000TECParamInitAlarm | This trap is issued when the TEC Parameter Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.20 | NodetrapEA1000AttnTableInitAlarm | This trap is issued when the Attenuator Table Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.21 | NodetrapEA1000PowerMeterTableInitAlarm | This trap is issued when the Power Meter Table Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.22 | NodetrapEA1000LaserDataCRCAlarm | This trap is issued when the Laser Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.23 | NodetrapEA1000AlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.24 | NodetrapEA1000FactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.25 | NodetrapEA1000UserRFOffAlarm | This trap is issued when the the User RF is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.26 | NodetrapEA1000UserOpticalOffAlarm | This trap is issued when the User Optical Power is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.33.27 | NodetrapEA1000ResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. |