MIB Viewer

OMNI-gx2EM-MIB

211 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.30.1Nodegx2emDescriptor
1.3.6.1.4.1.1166.6.1.2.30.1NodetrapEMConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.30.2Tablegx2emAnalogTablenot-accessiblemandatoryThis table contains gx2Em specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.30.2NodetrapEMConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.30.2.1Rowgx2emAnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.30.2.1.1Columngx2emAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.30.2.1.2ColumnlabelOffsetNomMonitorread-onlyoptionalThe value of this object provides the label of the Offset Monitor Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.3ColumnuomOffsetNomMonitorread-onlyoptionalThe value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.4ColumnmajorHighOffsetNomMonitorread-onlymandatoryThe value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.30.2.1.5ColumnmajorLowOffsetNomMonitorread-onlymandatoryThe value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.6ColumnminorHighOffsetNomMonitorread-onlymandatoryThe value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit…
1.3.6.1.4.1.1166.6.1.2.30.2.1.7ColumnminorLowOffsetNomMonitorread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit …
1.3.6.1.4.1.1166.6.1.2.30.2.1.8ColumncurrentValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
1.3.6.1.4.1.1166.6.1.2.30.2.1.9ColumnstateFlagOffsetNomMonitorread-onlymandatoryThe value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
1.3.6.1.4.1.1166.6.1.2.30.2.1.10ColumnminValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit …
1.3.6.1.4.1.1166.6.1.2.30.2.1.11ColumnmaxValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit …
1.3.6.1.4.1.1166.6.1.2.30.2.1.12ColumnalarmStateOffsetNomMonitorread-onlymandatoryThe value of this object provides the curent alarm state of the Offset Monitor Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.13ColumnlabelOffsetNomCntread-onlyoptionalThe value of this object provides the label of the Offset Control Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.14ColumnuomOffsetNomCntread-onlyoptionalThe value of this object provides the label of the Offset Control Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.15ColumnmajorHighOffsetNomCntread-onlymandatoryThe value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit…
1.3.6.1.4.1.1166.6.1.2.30.2.1.16ColumnmajorLowOffsetNomCntread-onlymandatoryThe value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit …
1.3.6.1.4.1.1166.6.1.2.30.2.1.17ColumnminorHighOffsetNomCntread-onlymandatoryThe value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.30.2.1.18ColumnminorLowOffsetNomCntread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.19ColumncurrentValueOffsetNomCntread-writemandatoryThe value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEE…
1.3.6.1.4.1.1166.6.1.2.30.2.1.20ColumnstateFlagOffsetNomCntread-onlymandatoryThe value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
1.3.6.1.4.1.1166.6.1.2.30.2.1.21ColumnminValueOffsetNomCntread-onlymandatoryThe value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.22ColumnmaxValueOffsetNomCntread-onlymandatoryThe value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.23ColumnalarmStateOffsetNomCntread-onlymandatoryThe value of this object provides the curent alarm state of the Offset Control Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.24ColumnlabelRelAttenSettingread-onlyoptionalThe value of this object provides the label of the Attenuator Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.25ColumnuomRelAttenSettingread-onlyoptionalThe value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.26ColumnmajorHighRelAttenSettingread-onlymandatoryThe value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.30.2.1.27ColumnmajorLowRelAttenSettingread-onlymandatoryThe value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.28ColumnminorHighRelAttenSettingread-onlymandatoryThe value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.30.2.1.29ColumnminorLowRelAttenSettingread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.30ColumncurrentValueRelAttenSettingread-writemandatoryThe value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.30.2.1.31ColumnstateFlagRelAttenSettingread-onlymandatoryThe value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.2.1.32ColumnminValueRelAttenSettingread-onlymandatoryThe value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.33ColumnmaxValueRelAttenSettingread-onlymandatoryThe value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.34ColumnalarmStateRelAttenSettingread-onlymandatoryThe value of this object provides the curent alarm state of the Attenuator Setting Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.35ColumnlabelOptPowerread-onlyoptionalThe value of this object provides the label of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.36ColumnuomOptPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.37ColumnmajorHighOptPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.38ColumnmajorLowOptPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.30.2.1.39ColumnminorHighOptPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.40ColumnminorLowOptPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.30.2.1.41ColumncurrentValueOptPowerread-onlymandatoryThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE…
1.3.6.1.4.1.1166.6.1.2.30.2.1.42ColumnstateFlagOptPowerread-onlymandatoryThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.2.1.43ColumnminValueOptPowerread-onlymandatoryThe value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.30.2.1.44ColumnmaxValueOptPowerread-onlymandatoryThe value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as…
1.3.6.1.4.1.1166.6.1.2.30.2.1.45ColumnalarmStateOptPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.46ColumnlabelLaserBiasread-onlyoptionalThe value of this object provides the label of the Laser Bias Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.47ColumnuomLaserBiasread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Bias Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.48ColumnmajorHighLaserBiasread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.49ColumnmajorLowLaserBiasread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.30.2.1.50ColumnminorHighLaserBiasread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.51ColumnminorLowLaserBiasread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.30.2.1.52ColumncurrentValueLaserBiasread-onlymandatoryThe value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32…
1.3.6.1.4.1.1166.6.1.2.30.2.1.53ColumnstateFlagLaserBiasread-onlymandatoryThe value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.2.1.54ColumnminValueLaserBiasread-onlymandatoryThe value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.30.2.1.55ColumnmaxValueLaserBiasread-onlymandatoryThe value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.30.2.1.56ColumnalarmStateLaserBiasread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Bias Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.57ColumnlabelTecCurrentread-onlyoptionalThe value of this object provides the label of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.58ColumnuomTecCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the TEC Current Analog parameter..
1.3.6.1.4.1.1166.6.1.2.30.2.1.59ColumnmajorHighTecCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.30.2.1.60ColumnmajorLowTecCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.61ColumnminorHighTecCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.30.2.1.62ColumnminorLowTecCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.63ColumncurrentValueTecCurrentread-onlymandatoryThe value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.30.2.1.64ColumnstateFlagTecCurrentread-onlymandatoryThe value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.2.1.65ColumnminValueTecCurrentread-onlymandatoryThe value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.66ColumnmaxValueTecCurrentread-onlymandatoryThe value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.67ColumnalarmStateTecCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.68ColumnlabelLaserTempread-onlyoptionalThe value of this object provides the label of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.69ColumnuomLaserTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.70ColumnmajorHighLaserTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.71ColumnmajorLowLaserTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.30.2.1.72ColumnminorHighLaserTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.73ColumnminorLowLaserTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.30.2.1.74ColumncurrentValueLaserTempread-onlymandatoryThe value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.30.2.1.75ColumnstateFlagLaserTempread-onlymandatoryThe value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.2.1.76ColumnminValueLaserTempread-onlymandatoryThe value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.30.2.1.77ColumnmaxValueLaserTempread-onlymandatoryThe value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.30.2.1.78ColumnalarmStateLaserTempread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.79ColumnlabelModuleTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.80ColumnuomModuleTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.81ColumnmajorHighModuleTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.30.2.1.82ColumnmajorLowModuleTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.83ColumnminorHighModuleTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.30.2.1.84ColumnminorLowModuleTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.85ColumncurrentValueModuleTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.30.2.1.86ColumnstateFlagModuleTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.2.1.87ColumnminValueModuleTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.88ColumnmaxValueModuleTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.30.2.1.89ColumnalarmStateModuleTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.90ColumnlabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.91ColumnuomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.92ColumnmajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.30.2.1.93ColumnmajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.94ColumnminorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.30.2.1.95ColumnminorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.96ColumncurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.30.2.1.97ColumnstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.2.1.98ColumnminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.99ColumnmaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.100ColumnalarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.101Columnlabel12Voltread-onlyoptionalThe value of this object provides the label of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.102Columnuom12Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.2.1.103ColumnmajorHigh12Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.30.2.1.104ColumnmajorLow12Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.105ColumnminorHigh12Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.30.2.1.106ColumnminorLow12Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.107ColumncurrentValue12Voltread-onlymandatoryThe value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.30.2.1.108ColumnstateFlag12Voltread-onlymandatoryThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.2.1.109ColumnminValue12Voltread-onlymandatoryThe value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.110ColumnmaxValue12Voltread-onlymandatoryThe value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.30.2.1.111ColumnalarmState12Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.30.3Tablegx2emDigitalTablenot-accessiblemandatoryThis table contains gx2Em specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.30.3NodetrapEMRFInputAlarmThis trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame…
1.3.6.1.4.1.1166.6.1.2.30.3.2Rowgx2emDigitalEntrynot-accessiblemandatoryThis list contains digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.30.3.2.1Columngx2emDigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.30.3.2.2ColumnlabelRfInputread-onlyoptionalThe value of this object provides the label of the RF Input Control Digital parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.3ColumnenumRfInputread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.30.3.2.4ColumnvalueRfInputread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.5ColumnstateflagRfInputread-onlymandatoryThe value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.3.2.6ColumnlabelOptOutputread-onlyoptionalThe value of this object provides the label of the Optical Output Control Digital parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.7ColumnenumOptOutputread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.30.3.2.8ColumnvalueOptOutputread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.9ColumnstateflagOptOutputread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.3.2.10ColumnlabelLaserModeread-onlyoptionalThe value of this object provides the label of the Laser Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.11ColumnenumLaserModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.30.3.2.12ColumnvalueLaserModeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.13ColumnstateflagLaserModeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.3.2.14ColumnlabelLaserSecModeread-onlyoptionalThe value of this object provides the label of the Laser Secondary Mode Digital parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.15ColumnenumLaserSecModeread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.30.3.2.16ColumnvalueLaserSecModeread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.17ColumnstateflagLaserSecModeread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.3.2.18ColumnlabelVideoOffsetread-onlyoptionalThe value of this object provides the label of the Video Offset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.19ColumnenumVideoOffsetread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.30.3.2.20ColumnvalueVideoOffsetread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.21ColumnstateflagVideoOffsetread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.3.2.22ColumnlabelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Reset Digital parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.23ColumnenumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.30.3.2.24ColumnvalueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.30.3.2.25ColumnstateflagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.4Tablegx2emStatusTablenot-accessiblemandatoryThis table contains gx2Em specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.30.4NodetrapEMRFOverloadAlarmThis trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par…
1.3.6.1.4.1.1166.6.1.2.30.4.3Rowgx2emStatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.30.4.3.1Columngx2emStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.30.4.3.2ColumnlabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.30.4.3.3ColumnvalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.30.4.3.4ColumnstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.4.3.5ColumnlabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.30.4.3.6ColumnvalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.30.4.3.7ColumnstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.4.3.8ColumnlabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.30.4.3.9ColumnvalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.30.4.3.10ColumnstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.4.3.11ColumnlabelLaserDataCRCread-onlyoptionalThe value of this object provides the label of the Laser Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.30.4.3.12ColumnvalueLaserDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.30.4.3.13ColumnstateflagLaserDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.4.3.14ColumnlabelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.30.4.3.15ColumnvalueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.30.4.3.16ColumnstateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.4.3.17ColumnlabelHWStatusread-onlyoptionalThe value of this object provides the label of the Laser Drive Level Status parameter.
1.3.6.1.4.1.1166.6.1.2.30.4.3.18ColumnvalueHWStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.30.4.3.19ColumnstateflagHWStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.4.3.20ColumnlabelRFInputStatusread-onlyoptionalThe value of this object provides the label of the RF Input Status parameter.
1.3.6.1.4.1.1166.6.1.2.30.4.3.21ColumnvalueRFInputStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.30.4.3.22ColumnstateflagRFInputStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.30.5Tablegx2emFactoryTablenot-accessiblemandatoryThis table contains gx2Em specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.30.5NodetrapEMRFOffsetAlarmThis trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this param…
1.3.6.1.4.1.1166.6.1.2.30.5.4Rowgx2emFactoryEntrynot-accessiblemandatoryThis list contains Factory parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.30.5.4.1Columngx2emFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.30.5.4.2ColumnbootControlByteValueread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.30.5.4.3ColumnbootStatusByteValueread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.30.5.4.4Columnbank1CRCValueread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.30.5.4.5Columnbank2CRCValueread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.30.5.4.6ColumnprgEEPROMByteValueread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.30.5.4.7ColumnfactoryCRCValueread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.30.5.4.8ColumncalculateCRCValueread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.30.5.4.9ColumnhourMeterValueread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.30.5.4.10ColumnflashPrgCntAValueread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.30.5.4.11ColumnflashPrgCntBValueread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.30.5.4.12ColumnflashBankARevValueread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.30.5.4.13ColumnflashBankBRevValueread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.30.6Tablegx2Em1000HoldTimeTablenot-accessiblemandatoryThis table contains gx2Em1000 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.30.6NodetrapEMOpticalPowerAlarmThis trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this p…
1.3.6.1.4.1.1166.6.1.2.30.6.5Rowgx2Em1000HoldTimeEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.30.6.5.1Columngx2Em1000HoldTimeTableIndexread-onlymandatoryThe value of this object is the index of the data object.
1.3.6.1.4.1.1166.6.1.2.30.6.5.2Columngx2Em1000HoldTimeSpecIndexread-onlymandatoryThe value of this object identifies the index of the alarm object to be modified.
1.3.6.1.4.1.1166.6.1.2.30.6.5.3Columngx2Em1000HoldTimeDataread-writemandatoryThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered…
1.3.6.1.4.1.1166.6.1.2.30.7NodetrapEMLaserBiasAlarmThis trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.30.8NodetrapEMLaserTempAlarmThis trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.30.9NodetrapEMTECCurrentAlarmThis trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par…
1.3.6.1.4.1.1166.6.1.2.30.10NodetrapEMFanCurrentAlarmThis trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par…
1.3.6.1.4.1.1166.6.1.2.30.11NodetrapEM12vAlarmThis trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this paramet…
1.3.6.1.4.1.1166.6.1.2.30.12NodetrapEMModuleTempAlarmThis trap is issued when the Laser Module Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.30.13NodetrapEMFlashAlarmThis trap is issued when the Laser Modules detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.30.14NodetrapEMLaserBiasCntLoopAlarmThis trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation.
1.3.6.1.4.1.1166.6.1.2.30.15NodetrapEMBankBootAlarmThis trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.30.16NodetrapEMLaserBiasCntLoopInitAlarmThis trap is issued when the Laser Bias Control loop init fails.
1.3.6.1.4.1.1166.6.1.2.30.17NodetrapEMRFParamInitAlarmThis trap is issued when the RF parameter Init fails.
1.3.6.1.4.1.1166.6.1.2.30.18NodetrapEMTECParamInitAlarmThis trap is issued when the TEC Parameter Init fails.
1.3.6.1.4.1.1166.6.1.2.30.19NodetrapEMAttnTableInitAlarmThis trap is issued when the Attenuator Table Init fails.
1.3.6.1.4.1.1166.6.1.2.30.20NodetrapEMPowerMeterTableInitAlarmThis trap is issued when the Power Meter Table Init fails.
1.3.6.1.4.1.1166.6.1.2.30.21NodetrapEMLaserDataCRCAlarmThis trap is issued when the Laser Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.30.22NodetrapEMAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.30.23NodetrapEMFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.30.24NodetrapEMUserRFOffAlarmThis trap is issued when the the User RF is turned off.
1.3.6.1.4.1.1166.6.1.2.30.25NodetrapEMUserOpticalOffAlarmThis trap is issued when the User Optical Power is turned off.
1.3.6.1.4.1.1166.6.1.2.30.26NodetrapEMResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.