OMNI-gx2Em870-MIB
159 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.12.1 | Nodegx2Em870Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.12.1 | NodetrapEM870ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.12.2 | Tablegx2Em870AnalogTable | not-accessible | mandatory | This table contains gx2Em870 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.12.2 | NodetrapEM870ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.12.2.1 | Rowgx2Em870AnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.1 | Columngx2Em870AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.2 | Columnem870labelOpticalPower | read-only | optional | The value of this object provides the label of the Optical Output Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.3 | Columnem870uomOpticalPower | read-only | optional | The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.4 | Columnem870majorHighOpticalPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.5 | Columnem870majorLowOpticalPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.6 | Columnem870minorHighOpticalPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is repres… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.7 | Columnem870minorLowOpticalPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.8 | Columnem870currentValueOpticalPower | read-only | mandatory | The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.9 | Columnem870stateFlagOpticalPower | read-only | mandatory | The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.10 | Columnem870minValueOpticalPower | read-only | mandatory | The value of this object provides the minimum value the Optical Output Power Analog parameter can achive. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.11 | Columnem870maxValueOpticalPower | read-only | mandatory | The value of this object provides the maximum value the Optical Output Power Analog parameter can achive. This value is a floating point number that is represe… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.12 | Columnem870alarmStateOpticalPower | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Output Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.13 | Columnem870labelOmiOffset | read-only | optional | The value of this object provides the label of the RF Input Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.14 | Columnem870uomOmiOffset | read-only | optional | The value of this object provides the Unit of Measure of the RF Input Power Analog parameter.. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.15 | Columnem870majorHighOmiOffset | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.16 | Columnem870majorLowOmiOffset | read-only | mandatory | The value of this object provides the Major Low alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.17 | Columnem870minorHighOmiOffset | read-only | mandatory | The value of this object provides the Minor High alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.18 | Columnem870minorLowOmiOffset | read-only | mandatory | The value of this object provides the Minor Low alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.19 | Columnem870currentValueOmiOffset | read-only | mandatory | The value of this object provides the Current value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEE… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.20 | Columnem870stateFlagOmiOffset | read-only | mandatory | The value of this object provides the state of the RF Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.21 | Columnem870minValueOmiOffset | read-only | mandatory | The value of this object provides the minimum value the RF Input Power Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.22 | Columnem870maxValueOmiOffset | read-only | mandatory | The value of this object provides the maximum value the RF Input Power Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.23 | Columnem870alarmStateOmiOffset | read-only | mandatory | The value of this object provides the curent alarm state of the RF Input Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.24 | Columnem870labelDFBPower | read-only | optional | The value of this object provides the label of the DFB Output Power Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.25 | Columnem870uomDFBPower | read-only | optional | The value of this object provides the Unit of Measure of the DFB Output Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.26 | Columnem870majorHighDFBPower | read-only | mandatory | The value of this object provides the Major High alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.27 | Columnem870majorLowDFBPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.28 | Columnem870minorHighDFBPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.29 | Columnem870minorLowDFBPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.30 | Columnem870currentValueDFBPower | read-only | mandatory | The value of this object provides the Current value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an I… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.31 | Columnem870stateFlagDFBPower | read-only | mandatory | The value of this object provides the state of the DFB Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.32 | Columnem870minValueDFBPower | read-only | mandatory | The value of this object provides the minimum value the DFB Output Power Analog parameter can achive. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.33 | Columnem870maxValueDFBPower | read-only | mandatory | The value of this object provides the maximum value the DFB Output Power Analog parameter can achive. This value is a floating point number that is represented… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.34 | Columnem870alarmStateDFBPower | read-only | mandatory | The value of this object provides the curent alarm state of the DFB Output Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.35 | Columnem870labelLaserBias | read-only | optional | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.36 | Columnem870uomLaserBias | read-only | optional | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.37 | Columnem870majorHighLaserBias | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.38 | Columnem870majorLowLaserBias | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.39 | Columnem870minorHighLaserBias | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.40 | Columnem870minorLowLaserBias | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.41 | Columnem870currentValueLaserBias | read-only | mandatory | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.42 | Columnem870stateFlagLaserBias | read-only | mandatory | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.43 | Columnem870minValueLaserBias | read-only | mandatory | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.44 | Columnem870maxValueLaserBias | read-only | mandatory | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.45 | Columnem870alarmStateLaserBias | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.46 | Columnem870labelCoolerCurrent | read-only | optional | The value of this object provides the label of the Cooler Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.47 | Columnem870uomCoolerCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Cooler Current Analog parameter.. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.48 | Columnem870majorHighCoolerCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.49 | Columnem870majorLowCoolerCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.50 | Columnem870minorHighCoolerCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.51 | Columnem870minorLowCoolerCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.52 | Columnem870currentValueCoolerCurrent | read-only | mandatory | The value of this object provides the Current value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEE… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.53 | Columnem870stateFlagCoolerCurrent | read-only | mandatory | The value of this object provides the state of the Cooler Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.54 | Columnem870minValueCoolerCurrent | read-only | mandatory | The value of this object provides the minimum value the Cooler Current Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.55 | Columnem870maxValueCoolerCurrent | read-only | mandatory | The value of this object provides the maximum value the Cooler Current Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.56 | Columnem870alarmStateCoolerCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Cooler Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.57 | Columnem870labelLaserTemp | read-only | optional | The value of this object provides the label of the Laser Temp Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.58 | Columnem870uomLaserTemp | read-only | optional | The value of this object provides the Unit of Measure of the Laser Temp Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.59 | Columnem870majorHighLaserTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.60 | Columnem870majorLowLaserTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.61 | Columnem870minorHighLaserTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.62 | Columnem870minorLowLaserTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.63 | Columnem870currentValueLaserTemp | read-only | mandatory | The value of this object provides the Current value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.64 | Columnem870stateFlagLaserTemp | read-only | mandatory | The value of this object provides the state of the Laser Temp Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.65 | Columnem870minValueLaserTemp | read-only | mandatory | The value of this object provides the minimum value the Laser TempAnalog parameter can achive. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.66 | Columnem870maxValueLaserTemp | read-only | mandatory | The value of this object provides the maximum value the Laser Temp Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.67 | Columnem870alarmStateLaserTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Temp Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.68 | Columnem870labelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.69 | Columnem870uomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.70 | Columnem870majorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.71 | Columnem870majorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.72 | Columnem870minorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.73 | Columnem870minorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.74 | Columnem870currentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.75 | Columnem870stateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.76 | Columnem870minValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.77 | Columnem870maxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.78 | Columnem870alarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.79 | Columnem870labelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.80 | Columnem870uomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.81 | Columnem870majorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.82 | Columnem870majorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.83 | Columnem870minorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.84 | Columnem870minorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.85 | Columnem870currentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.86 | Columnem870stateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.87 | Columnem870minValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.88 | Columnem870maxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.89 | Columnem870alarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.90 | Columnem870label12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.91 | Columnem870uom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.92 | Columnem870majorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.93 | Columnem870majorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.94 | Columnem870minorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.95 | Columnem870minorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.96 | Columnem870currentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.97 | Columnem870stateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.98 | Columnem870minValue12Volt | read-only | mandatory | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.99 | Columnem870maxValue12Volt | read-only | mandatory | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.12.2.1.100 | Columnem870alarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.3 | Tablegx2Em870DigitalTable | not-accessible | mandatory | This table contains gx2Em870 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.12.3 | NodetrapEM870FanCurrentAlarm | This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.12.3.4 | Rowgx2Em870DigitalEntry | not-accessible | mandatory | This list contains the digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.12.3.4.1 | Columngx2Em870DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.12.3.4.2 | Columnem870labelOpticalAlarmSetpoint | read-only | optional | The value of this object provides the label of the EM870's Optical Alarm setpoint Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.3.4.3 | Columnem870enumOpticalAlarmSetpoint | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.12.3.4.4 | Columnem870valueOpticalAlarmSetpoint | read-write | mandatory | The value of this object is the current value of the parameter. Note that reset setting returns the parameter to the off setting |
| 1.3.6.1.4.1.1166.6.1.2.12.3.4.5 | Columnem870stateFlagOpticalAlarmSetpoint | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.4 | Tablegx2Em870StatusTable | not-accessible | mandatory | This table contains gx2Em870 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.12.4 | NodetrapEM87012vAlarm | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this paramet… | ||
| 1.3.6.1.4.1.1166.6.1.2.12.4.2 | Rowgx2Em870StatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.1 | Columngx2Em870StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.2 | Columnem870labelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.3 | Columnem870valueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.4 | Columnem870stateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.5 | Columnem870labelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.6 | Columnem870valueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.7 | Columnem870stateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.8 | Columnem870labelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.9 | Columnem870valueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.10 | Columnem870stateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.11 | Columnem870labelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.12 | Columnem870valueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.13 | Columnem870stateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.14 | Columnem870labelCsoStatus | read-only | optional | The value of this object provides the label of the CSO Status parameter. This parameter is always hidden |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.15 | Columnem870valueCsoStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.12.4.2.16 | Columnem870stateflagCsoStatus | read-only | mandatory | The value of this object provides the state of the the CSO Status parameter. This parameter is always hidden (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.12.5 | Tablegx2Em870FactoryTable | not-accessible | mandatory | This table contains gx2Em870 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.12.5 | NodetrapEM870ModuleTempAlarm | This trap is issued when the Module Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.12.5.3 | Rowgx2Em870FactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.1 | Columngx2Em870FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.2 | Columnem870bootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.3 | Columnem870bootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.4 | Columnem870bank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.5 | Columnem870bank2CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.6 | Columnem870prgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.7 | Columnem870factoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.8 | Columnem870calculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.9 | Columnem870hourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.10 | Columnem870flashPrgCntA | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.11 | Columnem870flashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.12 | Columnem870flashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.12.5.3.13 | Columnem870flashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.12.6 | Tablegx2Em870HoldTimeTable | not-accessible | mandatory | This table contains gx2EM870 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.12.6 | NodetrapEM870OmiOffsetAlarm | This trap is issued when the Laser Modules OMI level parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this param… | ||
| 1.3.6.1.4.1.1166.6.1.2.12.6.5 | Rowgx2Em870HoldTimeEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.12.6.5.1 | Columngx2Em870HoldTimeTableIndex | read-only | mandatory | The value of this object is the index of the data object. |
| 1.3.6.1.4.1.1166.6.1.2.12.6.5.2 | Columngx2Em870HoldTimeSpecIndex | read-only | mandatory | The value of this object identifies the index of the alarm object to be modified. |
| 1.3.6.1.4.1.1166.6.1.2.12.6.5.3 | Columngx2Em870HoldTimeData | read-write | mandatory | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered… |
| 1.3.6.1.4.1.1166.6.1.2.12.7 | NodetrapEM870OpticalOutputPowerAlarm | This trap is issued when the Laser Modules Optical Output power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the… | ||
| 1.3.6.1.4.1.1166.6.1.2.12.8 | NodetrapEM870FlashAlarm | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.12.9 | NodetrapEM870BankBootAlarm | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.12.10 | NodetrapEM870AlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||