MIB Viewer

OMNI-gx2Em870-MIB

159 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.12.1Nodegx2Em870Descriptor
1.3.6.1.4.1.1166.6.1.2.12.1NodetrapEM870ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.12.2Tablegx2Em870AnalogTablenot-accessiblemandatoryThis table contains gx2Em870 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.12.2NodetrapEM870ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.12.2.1Rowgx2Em870AnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.12.2.1.1Columngx2Em870AnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.12.2.1.2Columnem870labelOpticalPowerread-onlyoptionalThe value of this object provides the label of the Optical Output Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.3Columnem870uomOpticalPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Optical Output Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.4Columnem870majorHighOpticalPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.12.2.1.5Columnem870majorLowOpticalPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.12.2.1.6Columnem870minorHighOpticalPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is repres…
1.3.6.1.4.1.1166.6.1.2.12.2.1.7Columnem870minorLowOpticalPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.12.2.1.8Columnem870currentValueOpticalPowerread-onlymandatoryThe value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.12.2.1.9Columnem870stateFlagOpticalPowerread-onlymandatoryThe value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.10Columnem870minValueOpticalPowerread-onlymandatoryThe value of this object provides the minimum value the Optical Output Power Analog parameter can achive. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.12.2.1.11Columnem870maxValueOpticalPowerread-onlymandatoryThe value of this object provides the maximum value the Optical Output Power Analog parameter can achive. This value is a floating point number that is represe…
1.3.6.1.4.1.1166.6.1.2.12.2.1.12Columnem870alarmStateOpticalPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Optical Output Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.13Columnem870labelOmiOffsetread-onlyoptionalThe value of this object provides the label of the RF Input Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.14Columnem870uomOmiOffsetread-onlyoptionalThe value of this object provides the Unit of Measure of the RF Input Power Analog parameter..
1.3.6.1.4.1.1166.6.1.2.12.2.1.15Columnem870majorHighOmiOffsetread-onlymandatoryThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.16Columnem870majorLowOmiOffsetread-onlymandatoryThe value of this object provides the Major Low alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.17Columnem870minorHighOmiOffsetread-onlymandatoryThe value of this object provides the Minor High alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.12.2.1.18Columnem870minorLowOmiOffsetread-onlymandatoryThe value of this object provides the Minor Low alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.19Columnem870currentValueOmiOffsetread-onlymandatoryThe value of this object provides the Current value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEE…
1.3.6.1.4.1.1166.6.1.2.12.2.1.20Columnem870stateFlagOmiOffsetread-onlymandatoryThe value of this object provides the state of the RF Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.21Columnem870minValueOmiOffsetread-onlymandatoryThe value of this object provides the minimum value the RF Input Power Analog parameter can achive. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.22Columnem870maxValueOmiOffsetread-onlymandatoryThe value of this object provides the maximum value the RF Input Power Analog parameter can achive. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.23Columnem870alarmStateOmiOffsetread-onlymandatoryThe value of this object provides the curent alarm state of the RF Input Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.24Columnem870labelDFBPowerread-onlyoptionalThe value of this object provides the label of the DFB Output Power Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.25Columnem870uomDFBPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the DFB Output Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.26Columnem870majorHighDFBPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.12.2.1.27Columnem870majorLowDFBPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.12.2.1.28Columnem870minorHighDFBPowerread-onlymandatoryThe value of this object provides the Minor High alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represente…
1.3.6.1.4.1.1166.6.1.2.12.2.1.29Columnem870minorLowDFBPowerread-onlymandatoryThe value of this object provides the Minor Low alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.12.2.1.30Columnem870currentValueDFBPowerread-onlymandatoryThe value of this object provides the Current value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an I…
1.3.6.1.4.1.1166.6.1.2.12.2.1.31Columnem870stateFlagDFBPowerread-onlymandatoryThe value of this object provides the state of the DFB Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.32Columnem870minValueDFBPowerread-onlymandatoryThe value of this object provides the minimum value the DFB Output Power Analog parameter can achive. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.12.2.1.33Columnem870maxValueDFBPowerread-onlymandatoryThe value of this object provides the maximum value the DFB Output Power Analog parameter can achive. This value is a floating point number that is represented…
1.3.6.1.4.1.1166.6.1.2.12.2.1.34Columnem870alarmStateDFBPowerread-onlymandatoryThe value of this object provides the curent alarm state of the DFB Output Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.35Columnem870labelLaserBiasread-onlyoptionalThe value of this object provides the label of the Laser Bias Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.36Columnem870uomLaserBiasread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Bias Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.37Columnem870majorHighLaserBiasread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.38Columnem870majorLowLaserBiasread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.12.2.1.39Columnem870minorHighLaserBiasread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.40Columnem870minorLowLaserBiasread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.12.2.1.41Columnem870currentValueLaserBiasread-onlymandatoryThe value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32…
1.3.6.1.4.1.1166.6.1.2.12.2.1.42Columnem870stateFlagLaserBiasread-onlymandatoryThe value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.43Columnem870minValueLaserBiasread-onlymandatoryThe value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.12.2.1.44Columnem870maxValueLaserBiasread-onlymandatoryThe value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.12.2.1.45Columnem870alarmStateLaserBiasread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Bias Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.46Columnem870labelCoolerCurrentread-onlyoptionalThe value of this object provides the label of the Cooler Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.47Columnem870uomCoolerCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Cooler Current Analog parameter..
1.3.6.1.4.1.1166.6.1.2.12.2.1.48Columnem870majorHighCoolerCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.12.2.1.49Columnem870majorLowCoolerCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.50Columnem870minorHighCoolerCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented …
1.3.6.1.4.1.1166.6.1.2.12.2.1.51Columnem870minorLowCoolerCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.52Columnem870currentValueCoolerCurrentread-onlymandatoryThe value of this object provides the Current value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEE…
1.3.6.1.4.1.1166.6.1.2.12.2.1.53Columnem870stateFlagCoolerCurrentread-onlymandatoryThe value of this object provides the state of the Cooler Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.54Columnem870minValueCoolerCurrentread-onlymandatoryThe value of this object provides the minimum value the Cooler Current Analog parameter can achive. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.55Columnem870maxValueCoolerCurrentread-onlymandatoryThe value of this object provides the maximum value the Cooler Current Analog parameter can achive. This value is a floating point number that is represented a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.56Columnem870alarmStateCoolerCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Cooler Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.57Columnem870labelLaserTempread-onlyoptionalThe value of this object provides the label of the Laser Temp Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.58Columnem870uomLaserTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Temp Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.59Columnem870majorHighLaserTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.60Columnem870majorLowLaserTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.12.2.1.61Columnem870minorHighLaserTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.62Columnem870minorLowLaserTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.12.2.1.63Columnem870currentValueLaserTempread-onlymandatoryThe value of this object provides the Current value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32…
1.3.6.1.4.1.1166.6.1.2.12.2.1.64Columnem870stateFlagLaserTempread-onlymandatoryThe value of this object provides the state of the Laser Temp Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.65Columnem870minValueLaserTempread-onlymandatoryThe value of this object provides the minimum value the Laser TempAnalog parameter can achive. This value is a floating point number that is represented as an …
1.3.6.1.4.1.1166.6.1.2.12.2.1.66Columnem870maxValueLaserTempread-onlymandatoryThe value of this object provides the maximum value the Laser Temp Analog parameter can achive. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.12.2.1.67Columnem870alarmStateLaserTempread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Temp Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.68Columnem870labelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.69Columnem870uomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.70Columnem870majorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.12.2.1.71Columnem870majorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.12.2.1.72Columnem870minorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen…
1.3.6.1.4.1.1166.6.1.2.12.2.1.73Columnem870minorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.12.2.1.74Columnem870currentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an…
1.3.6.1.4.1.1166.6.1.2.12.2.1.75Columnem870stateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.76Columnem870minValueModTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.12.2.1.77Columnem870maxValueModTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent…
1.3.6.1.4.1.1166.6.1.2.12.2.1.78Columnem870alarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.79Columnem870labelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.80Columnem870uomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.81Columnem870majorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.12.2.1.82Columnem870majorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.83Columnem870minorHighFanCurrentread-onlymandatoryThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.12.2.1.84Columnem870minorLowFanCurrentread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.85Columnem870currentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.12.2.1.86Columnem870stateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.87Columnem870minValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.88Columnem870maxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.89Columnem870alarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.90Columnem870label12Voltread-onlyoptionalThe value of this object provides the label of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.91Columnem870uom12Voltread-onlyoptionalThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.2.1.92Columnem870majorHigh12Voltread-onlymandatoryThe value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.12.2.1.93Columnem870majorLow12Voltread-onlymandatoryThe value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.94Columnem870minorHigh12Voltread-onlymandatoryThe value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as …
1.3.6.1.4.1.1166.6.1.2.12.2.1.95Columnem870minorLow12Voltread-onlymandatoryThe value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.96Columnem870currentValue12Voltread-onlymandatoryThe value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 3…
1.3.6.1.4.1.1166.6.1.2.12.2.1.97Columnem870stateFlag12Voltread-onlymandatoryThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.2.1.98Columnem870minValue12Voltread-onlymandatoryThe value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.99Columnem870maxValue12Voltread-onlymandatoryThe value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.12.2.1.100Columnem870alarmState12Voltread-onlymandatoryThe value of this object provides the curent alarm state of the 12v Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.12.3Tablegx2Em870DigitalTablenot-accessiblemandatoryThis table contains gx2Em870 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.12.3NodetrapEM870FanCurrentAlarmThis trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par…
1.3.6.1.4.1.1166.6.1.2.12.3.4Rowgx2Em870DigitalEntrynot-accessiblemandatoryThis list contains the digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.12.3.4.1Columngx2Em870DigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.12.3.4.2Columnem870labelOpticalAlarmSetpointread-onlyoptionalThe value of this object provides the label of the EM870's Optical Alarm setpoint Digital parameter.
1.3.6.1.4.1.1166.6.1.2.12.3.4.3Columnem870enumOpticalAlarmSetpointread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.12.3.4.4Columnem870valueOpticalAlarmSetpointread-writemandatoryThe value of this object is the current value of the parameter. Note that reset setting returns the parameter to the off setting
1.3.6.1.4.1.1166.6.1.2.12.3.4.5Columnem870stateFlagOpticalAlarmSetpointread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.4Tablegx2Em870StatusTablenot-accessiblemandatoryThis table contains gx2Em870 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.12.4NodetrapEM87012vAlarmThis trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this paramet…
1.3.6.1.4.1.1166.6.1.2.12.4.2Rowgx2Em870StatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.12.4.2.1Columngx2Em870StatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.12.4.2.2Columnem870labelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.12.4.2.3Columnem870valueBootread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.12.4.2.4Columnem870stateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.4.2.5Columnem870labelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.12.4.2.6Columnem870valueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.12.4.2.7Columnem870stateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.4.2.8Columnem870labelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.12.4.2.9Columnem870valueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.12.4.2.10Columnem870stateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.4.2.11Columnem870labelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.12.4.2.12Columnem870valueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.12.4.2.13Columnem870stateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.4.2.14Columnem870labelCsoStatusread-onlyoptionalThe value of this object provides the label of the CSO Status parameter. This parameter is always hidden
1.3.6.1.4.1.1166.6.1.2.12.4.2.15Columnem870valueCsoStatusread-onlymandatoryThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
1.3.6.1.4.1.1166.6.1.2.12.4.2.16Columnem870stateflagCsoStatusread-onlymandatoryThe value of this object provides the state of the the CSO Status parameter. This parameter is always hidden (0-Hidden 1-Read-Only, 2-Updateable).
1.3.6.1.4.1.1166.6.1.2.12.5Tablegx2Em870FactoryTablenot-accessiblemandatoryThis table contains gx2Em870 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.12.5NodetrapEM870ModuleTempAlarmThis trap is issued when the Module Temperature goes out of range.
1.3.6.1.4.1.1166.6.1.2.12.5.3Rowgx2Em870FactoryEntrynot-accessiblemandatoryThis list contains Factory parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.12.5.3.1Columngx2Em870FactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.12.5.3.2Columnem870bootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.12.5.3.3Columnem870bootStatusByteread-onlymandatoryThis object indicates the status of the last boot
1.3.6.1.4.1.1166.6.1.2.12.5.3.4Columnem870bank1CRCread-onlymandatoryThis object provides the CRC code of bank 0.
1.3.6.1.4.1.1166.6.1.2.12.5.3.5Columnem870bank2CRCread-onlymandatoryThis object provides the CRC code of bank 1.
1.3.6.1.4.1.1166.6.1.2.12.5.3.6Columnem870prgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.12.5.3.7Columnem870factoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.12.5.3.8Columnem870calculateCRCread-onlymandatoryThis object indicates which of the Emnums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.12.5.3.9Columnem870hourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.12.5.3.10Columnem870flashPrgCntAread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.12.5.3.11Columnem870flashPrgCntBread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.12.5.3.12Columnem870flashBankARevread-onlymandatoryThis object provides the revision of flash bank 0.
1.3.6.1.4.1.1166.6.1.2.12.5.3.13Columnem870flashBankBRevread-onlymandatoryThis object provides the revision of flash bank 1.
1.3.6.1.4.1.1166.6.1.2.12.6Tablegx2Em870HoldTimeTablenot-accessiblemandatoryThis table contains gx2EM870 specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.12.6NodetrapEM870OmiOffsetAlarmThis trap is issued when the Laser Modules OMI level parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this param…
1.3.6.1.4.1.1166.6.1.2.12.6.5Rowgx2Em870HoldTimeEntrynot-accessiblemandatoryThis list contains digital product class and the associated RF channel parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.12.6.5.1Columngx2Em870HoldTimeTableIndexread-onlymandatoryThe value of this object is the index of the data object.
1.3.6.1.4.1.1166.6.1.2.12.6.5.2Columngx2Em870HoldTimeSpecIndexread-onlymandatoryThe value of this object identifies the index of the alarm object to be modified.
1.3.6.1.4.1.1166.6.1.2.12.6.5.3Columngx2Em870HoldTimeDataread-writemandatoryThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered…
1.3.6.1.4.1.1166.6.1.2.12.7NodetrapEM870OpticalOutputPowerAlarmThis trap is issued when the Laser Modules Optical Output power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the…
1.3.6.1.4.1.1166.6.1.2.12.8NodetrapEM870FlashAlarmThis trap is issued when the Laser Modules detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.12.9NodetrapEM870BankBootAlarmThis trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.12.10NodetrapEM870AlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.12.11NodetrapEM870FactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.