OMNI-gx2GS1000-MIB
208 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.36.1 | Nodegx2gs1000Descriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.36.1 | NodetrapGS1000ConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.2 | Tablegx2gs1000AnalogTable | not-accessible | mandatory | This table contains gx2Gs1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.36.2 | NodetrapGS1000ConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.36.2.1 | Rowgx2gs1000AnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.1 | Columngx2gs1000AnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.2 | Columngs1000labelOffsetNomMonitor | read-only | optional | The value of this object provides the label of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.3 | Columngs1000uomOffsetNomMonitor | read-only | optional | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.4 | Columngs1000majorHighOffsetNomMonitor | read-only | mandatory | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.5 | Columngs1000majorLowOffsetNomMonitor | read-only | mandatory | The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.6 | Columngs1000minorHighOffsetNomMonitor | read-only | mandatory | The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.7 | Columngs1000minorLowOffsetNomMonitor | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.8 | Columngs1000currentValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.9 | Columngs1000stateFlagOffsetNomMonitor | read-only | mandatory | The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.10 | Columngs1000minValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.11 | Columngs1000maxValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.12 | Columngs1000alarmStateOffsetNomMonitor | read-only | mandatory | The value of this object provides the curent alarm state of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.13 | Columngs1000labelOffsetNomCnt | read-only | optional | The value of this object provides the label of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.14 | Columngs1000uomOffsetNomCnt | read-only | optional | The value of this object provides the label of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.15 | Columngs1000majorHighOffsetNomCnt | read-only | optional | The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.16 | Columngs1000majorLowOffsetNomCnt | read-only | optional | The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.17 | Columngs1000minorHighOffsetNomCnt | read-only | optional | The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.18 | Columngs1000minorLowOffsetNomCnt | read-only | optional | The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.19 | Columngs1000currentValueOffsetNomCnt | read-write | mandatory | The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEE… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.20 | Columngs1000stateFlagOffsetNomCnt | read-only | mandatory | The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.21 | Columngs1000minValueOffsetNomCnt | read-only | mandatory | The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.22 | Columngs1000maxValueOffsetNomCnt | read-only | mandatory | The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.23 | Columngs1000alarmStateOffsetNomCnt | read-only | mandatory | The value of this object provides the curent alarm state of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.24 | Columngs1000labelOptPower | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.25 | Columngs1000uomOptPower | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.26 | Columngs1000majorHighOptPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.27 | Columngs1000majorLowOptPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.28 | Columngs1000minorHighOptPower | read-only | optional | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.29 | Columngs1000minorLowOptPower | read-only | optional | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.30 | Columngs1000currentValueOptPower | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.31 | Columngs1000stateFlagOptPower | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.32 | Columngs1000minValueOptPower | read-only | mandatory | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.33 | Columngs1000maxValueOptPower | read-only | mandatory | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.34 | Columngs1000alarmStateOptPower | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.35 | Columngs1000labelLaserTemp | read-only | optional | The value of this object provides the label of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.36 | Columngs1000uomLaserTemp | read-only | optional | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.37 | Columngs1000majorHighLaserTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.38 | Columngs1000majorLowLaserTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.39 | Columngs1000minorHighLaserTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.40 | Columngs1000minorLowLaserTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.41 | Columngs1000currentValueLaserTemp | read-only | mandatory | The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.42 | Columngs1000stateFlagLaserTemp | read-only | mandatory | The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.43 | Columngs1000minValueLaserTemp | read-only | mandatory | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.44 | Columngs1000maxValueLaserTemp | read-only | mandatory | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.45 | Columngs1000alarmStateLaserTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.46 | Columngs1000labelLaserBias | read-only | optional | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.47 | Columngs1000uomLaserBias | read-only | optional | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.48 | Columngs1000majorHighLaserBias | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.49 | Columngs1000majorLowLaserBias | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.50 | Columngs1000minorHighLaserBias | read-only | optional | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.51 | Columngs1000minorLowLaserBias | read-only | optional | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.52 | Columngs1000currentValueLaserBias | read-only | mandatory | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.53 | Columngs1000stateFlagLaserBias | read-only | mandatory | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.54 | Columngs1000minValueLaserBias | read-only | mandatory | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.55 | Columngs1000maxValueLaserBias | read-only | mandatory | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.56 | Columngs1000alarmStateLaserBias | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.57 | Columngs1000labelTecCurrent | read-only | optional | The value of this object provides the label of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.58 | Columngs1000uomTecCurrent | read-only | optional | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.59 | Columngs1000majorHighTecCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.60 | Columngs1000majorLowTecCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.61 | Columngs1000minorHighTecCurrent | read-only | optional | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.62 | Columngs1000minorLowTecCurrent | read-only | optional | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.63 | Columngs1000currentValueTecCurrent | read-only | mandatory | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.64 | Columngs1000stateFlagTecCurrent | read-only | mandatory | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.65 | Columngs1000minValueTecCurrent | read-only | mandatory | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.66 | Columngs1000maxValueTecCurrent | read-only | mandatory | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.67 | Columngs1000alarmStateTecCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.68 | Columngs1000labelModuleTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.69 | Columngs1000uomModuleTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.70 | Columngs1000majorHighModuleTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.71 | Columngs1000majorLowModuleTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.72 | Columngs1000minorHighModuleTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.73 | Columngs1000minorLowModuleTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.74 | Columngs1000currentValueModuleTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.75 | Columngs1000stateFlagModuleTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.76 | Columngs1000minValueModuleTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.77 | Columngs1000maxValueModuleTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.78 | Columngs1000alarmStateModuleTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.79 | Columngs1000labelFan1Speed | read-only | optional | The value of this object provides the label of the Fan 1 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.80 | Columngs1000uomFan1Speed | read-only | optional | The value of this object provides the Unit of Measure of the Fan 1 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.81 | Columngs1000majorHighFan1Speed | read-only | optional | The value of this object provides the Major High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.82 | Columngs1000majorLowFan1Speed | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.83 | Columngs1000minorHighFan1Speed | read-only | optional | The value of this object provides the Minor High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.84 | Columngs1000minorLowFan1Speed | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.85 | Columngs1000currentValueFan1Speed | read-only | mandatory | The value of this object provides the Current value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.86 | Columngs1000stateFlagFan1Speed | read-only | mandatory | The value of this object provides the state of the Fan 1 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.87 | Columngs1000minValueFan1Speed | read-only | mandatory | The value of this object provides the minimum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.88 | Columngs1000maxValueFan1Speed | read-only | mandatory | The value of this object provides the maximum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.89 | Columngs1000alarmStateFan1Speed | read-only | mandatory | The value of this object provides the curent alarm state of the Fan 1 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.90 | Columngs1000labelFan2Speed | read-only | optional | The value of this object provides the label of the Fan 2 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.91 | Columngs1000uomFan2Speed | read-only | optional | The value of this object provides the Unit of Measure of the Fan 2 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.92 | Columngs1000majorHighFan2Speed | read-only | optional | The value of this object provides the Major High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.93 | Columngs1000majorLowFan2Speed | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.94 | Columngs1000minorHighFan2Speed | read-only | optional | The value of this object provides the Minor High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.95 | Columngs1000minorLowFan2Speed | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.96 | Columngs1000currentValueFan2Speed | read-only | mandatory | The value of this object provides the Current value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.97 | Columngs1000stateFlagFan2Speed | read-only | mandatory | The value of this object provides the state of the Fan 2 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.98 | Columngs1000minValueFan2Speed | read-only | mandatory | The value of this object provides the minimum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.99 | Columngs1000maxValueFan2Speed | read-only | mandatory | The value of this object provides the maximum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.100 | Columngs1000alarmStateFan2Speed | read-only | mandatory | The value of this object provides the curent alarm state of the Fan 2 Speed Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.101 | Columngs1000label12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.102 | Columngs1000uom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.103 | Columngs1000majorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.104 | Columngs1000majorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.105 | Columngs1000minorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.106 | Columngs1000minorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.107 | Columngs1000currentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.108 | Columngs1000stateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.109 | Columngs1000minValue12Volt | read-only | mandatory | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.110 | Columngs1000maxValue12Volt | read-only | mandatory | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.36.2.1.111 | Columngs1000alarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3 | Tablegx2gs1000DigitalTable | not-accessible | mandatory | This table contains gx2Gs1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.36.3 | NodetrapGS1000RFInputAlarm | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.3.2 | Rowgx2gs1000DigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.1 | Columngx2gs1000DigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.2 | Columngs1000labelRfInput | read-only | optional | The value of this object provides the label of the RF Input Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.3 | Columngs1000enumRfInput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.4 | Columngs1000valueRfInput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.5 | Columngs1000stateflagRfInput | read-only | mandatory | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.6 | Columngs1000labelOptOutput | read-only | optional | The value of this object provides the label of the Optical Output Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.7 | Columngs1000enumOptOutput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.8 | Columngs1000valueOptOutput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.9 | Columngs1000stateflagOptOutput | read-only | mandatory | The value of this object provides the gs1000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.10 | Columngs1000labelLaserMode | read-only | optional | The value of this object provides the label of the Laser Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.11 | Columngs1000enumLaserMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.12 | Columngs1000valueLaserMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.13 | Columngs1000stateflagLaserMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.14 | Columngs1000labelAttenSetting | read-only | optional | The value of this object provides the label of the Attenuation Setting Ditital Parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.15 | Columngs1000enumAttenSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.16 | Columngs1000valueAttenSetting | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.17 | Columngs1000stateflagAttenSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.18 | Columngs1000labelLaserSecMode | read-only | optional | The value of this object provides the label of the Laser Secondary Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.19 | Columngs1000enumLaserSecMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.20 | Columngs1000valueLaserSecMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.21 | Columngs1000stateflagLaserSecMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.22 | Columngs1000labelVideoOffset | read-only | optional | The value of this object provides the label of the Video Offset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.23 | Columngs1000enumVideoOffset | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.24 | Columngs1000valueVideoOffset | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.25 | Columngs1000stateflagVideoOffset | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.26 | Columngs1000labelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.27 | Columngs1000enumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.28 | Columngs1000valueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.3.2.29 | Columngs1000stateflagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.4 | Tablegx2gs1000StatusTable | not-accessible | mandatory | This table contains gx2Gs1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.36.4 | NodetrapGS1000RFOverloadAlarm | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.4.3 | Rowgx2gs1000StatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.1 | Columngx2gs1000StatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.2 | Columngs1000labelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.3 | Columngs1000valueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.4 | Columngs1000stateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.5 | Columngs1000labelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.6 | Columngs1000valueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.7 | Columngs1000stateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.8 | Columngs1000labelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.9 | Columngs1000valueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.10 | Columngs1000stateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.11 | Columngs1000labelLaserDataCRC | read-only | optional | The value of this object provides the label of the Laser Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.12 | Columngs1000valueLaserDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.13 | Columngs1000stateflagLaserDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.14 | Columngs1000labelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.15 | Columngs1000valueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.16 | Columngs1000stateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.17 | Columngs1000labelRFInputStatus | read-only | optional | The value of this object provides the label of the RF Input Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.18 | Columngs1000valueRFInputStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.19 | Columngs1000stateflagRFInputStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.36.5 | Tablegx2gs1000FactoryTable | not-accessible | mandatory | This table contains gx2Gs1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.36.5 | NodetrapGS1000RFOffsetAlarm | This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this param… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.5.4 | Rowgx2gs1000FactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.1 | Columngx2gs1000FactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.2 | Columngs1000bootControlByteValue | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.3 | Columngs1000bootStatusByteValue | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.4 | Columngs1000bank1CRCValue | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.5 | Columngs1000bank2CRCValue | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.6 | Columngs1000prgEEPROMByteValue | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.7 | Columngs1000factoryCRCValue | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.8 | Columngs1000calculateCRCValue | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.9 | Columngs1000hourMeterValue | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.10 | Columngs1000flashPrgCntAValue | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.11 | Columngs1000flashPrgCntBValue | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.12 | Columngs1000flashBankARevValue | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.36.5.4.13 | Columngs1000flashBankBRevValue | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.36.6 | NodetrapGS1000OpticalPowerAlarm | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this p… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.7 | NodetrapGS1000LaserBiasAlarm | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.8 | NodetrapGS1000LaserTempAlarm | This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.9 | NodetrapGS1000TECCurrentAlarm | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.10 | NodetrapGS1000Fan1SpeedAlarm | This trap is issued when the Laser Modules Fan 1 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.11 | NodetrapGS1000Fan2SpeedAlarm | This trap is issued when the Laser Modules Fan 2 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.12 | NodetrapGS100012vAlarm | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this paramet… | ||
| 1.3.6.1.4.1.1166.6.1.2.36.13 | NodetrapGS1000ModuleTempAlarm | This trap is issued when the Laser Module Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.14 | NodetrapGS1000FlashAlarm | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.15 | NodetrapGS1000LaserBiasCntLoopAlarm | This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.16 | NodetrapGS1000BankBootAlarm | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.17 | NodetrapGS1000LaserBiasCntLoopInitAlarm | This trap is issued when the Laser Bias Control loop init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.18 | NodetrapGS1000RFParamInitAlarm | This trap is issued when the RF parameter Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.19 | NodetrapGS1000TECParamInitAlarm | This trap is issued when the TEC Parameter Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.20 | NodetrapGS1000AttnTableInitAlarm | This trap is issued when the Attenuator Table Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.21 | NodetrapGS1000PowerMeterTableInitAlarm | This trap is issued when the Power Meter Table Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.22 | NodetrapGS1000LaserDataCRCAlarm | This trap is issued when the Laser Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.23 | NodetrapGS1000AlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.24 | NodetrapGS1000FactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.25 | NodetrapGS1000UserRFOffAlarm | This trap is issued when the the User RF is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.26 | NodetrapGS1000UserOpticalOffAlarm | This trap is issued when the User Optical Power is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.36.27 | NodetrapGS1000ResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. |