MIB Viewer

OMNI-gx2Lm1000s-MIB

156 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1.2.31.1Nodegx2Lm1000sDescriptor
1.3.6.1.4.1.1166.6.1.2.31.1NodetrapLM1000SConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre…
1.3.6.1.4.1.1166.6.1.2.31.2Tablegx2Lm1000sAnalogTablenot-accessiblemandatoryThis table contains gx2Lm1000s specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.31.2NodetrapLM1000SConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may …
1.3.6.1.4.1.1166.6.1.2.31.2.1Rowgx2Lm1000sAnalogEntrynot-accessiblemandatoryThis list contains the analog parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.31.2.1.1Columngx2Lm1000sAnalogTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.31.2.1.2Columnlm1000slabelOffsetNomMonitorread-onlyoptionalThe value of this object provides the label of the Offset Monitor Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.3Columnlm1000suomOffsetNomMonitorread-onlyoptionalThe value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. The unit of measure for this parameter is dB
1.3.6.1.4.1.1166.6.1.2.31.2.1.4Columnlm1000smajorHighOffsetNomMonitorread-onlyobsoleteThe value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This object is not used by this module and always returns …
1.3.6.1.4.1.1166.6.1.2.31.2.1.5Columnlm1000smajorLowOffsetNomMonitorread-onlyobsoleteThe value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always ret…
1.3.6.1.4.1.1166.6.1.2.31.2.1.6Columnlm1000sminorHighOffsetNomMonitorread-onlyobsoleteThe value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always re…
1.3.6.1.4.1.1166.6.1.2.31.2.1.7Columnlm1000sminorLowOffsetNomMonitorread-onlyobsoleteThe value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always ret…
1.3.6.1.4.1.1166.6.1.2.31.2.1.8Columnlm1000scurrentValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the Current value of the Offset Monitor Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.9Columnlm1000sstateFlagOffsetNomMonitorread-onlymandatoryThe value of this object provides the state of the Offset Monitor Power Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.2.1.10Columnlm1000sminValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.11Columnlm1000smaxValueOffsetNomMonitorread-onlymandatoryThe value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.12Columnlm1000salarmStateOffsetNomMonitorread-onlymandatoryThe value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.13Columnlm1000slabelLaserPowerread-onlyoptionalThe value of this object provides the label of the Laser Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.14Columnlm1000suomLaserPowerread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter. The unit of measure for this parameter is dBm
1.3.6.1.4.1.1166.6.1.2.31.2.1.15Columnlm1000smajorHighLaserPowerread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.16Columnlm1000smajorLowLaserPowerread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.17Columnlm1000sminorHighLaserPowerread-onlyobsoleteThe value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always ret…
1.3.6.1.4.1.1166.6.1.2.31.2.1.18Columnlm1000sminorLowLaserPowerread-onlyobsoleteThe value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always retu…
1.3.6.1.4.1.1166.6.1.2.31.2.1.19Columnlm1000scurrentValueLaserPowerread-onlymandatoryThe value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as a…
1.3.6.1.4.1.1166.6.1.2.31.2.1.20Columnlm1000sstateFlagLaserPowerread-onlymandatoryThe value of this object provides the state of the Laser Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.2.1.21Columnlm1000sminValueLaserPowerread-onlymandatoryThe value of this object provides the minimum value the Laser Optical Power Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.22Columnlm1000smaxValueLaserPowerread-onlymandatoryThe value of this object provides the maximum value the Laser Optical Power Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.23Columnlm1000salarmStateLaserPowerread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Optical Power Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.24Columnlm1000slabelLaserTempread-onlyoptionalThe value of this object provides the label of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.25Columnlm1000suomLaserTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. The unit of measure for this parameter is degrees C
1.3.6.1.4.1.1166.6.1.2.31.2.1.26Columnlm1000smajorHighLaserTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.27Columnlm1000smajorLowLaserTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.28Columnlm1000sminorHighLaserTempread-onlyobsoleteThe value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.29Columnlm1000sminorLowLaserTempread-onlyobsoleteThe value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.30Columnlm1000scurrentValueLaserTempread-onlymandatoryThe value of this object provides the Current value of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.31Columnlm1000sstateFlagLaserTempread-onlymandatoryThe value of this object provides the state of the Laser Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.2.1.32Columnlm1000sminValueLaserTempread-onlymandatoryThe value of this object provides the minimum value the Laser Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.33Columnlm1000smaxValueLaserTempread-onlymandatoryThe value of this object provides the maximum value the Laser Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.34Columnlm1000salarmStateLaserTempread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.35Columnlm1000slabelLaserCurrentread-onlyoptionalThe value of this object provides the label of the Laser Bias Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.36Columnlm1000suomLaserCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter. The unit of measure for this parameter is mA
1.3.6.1.4.1.1166.6.1.2.31.2.1.37Columnlm1000smajorHighLaserCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.38Columnlm1000smajorLowLaserCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.39Columnlm1000sminorHighLaserCurrentread-onlyobsoleteThe value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always retu…
1.3.6.1.4.1.1166.6.1.2.31.2.1.40Columnlm1000sminorLowLaserCurrentread-onlyobsoleteThe value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always retur…
1.3.6.1.4.1.1166.6.1.2.31.2.1.41Columnlm1000scurrentValueLaserCurrentread-onlymandatoryThe value of this object provides the Current value of the Laser Bias Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.42Columnlm1000sstateFlagLaserCurrentread-onlymandatoryThe value of this object provides the state of the Laser Bias Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.2.1.43Columnlm1000sminValueLaserCurrentread-onlymandatoryThe value of this object provides the minimum value the Laser Bias Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.44Columnlm1000smaxValueLaserCurrentread-onlymandatoryThe value of this object provides the maximum value the Laser Bias Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.45Columnlm1000salarmStateLaserCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Laser Bias Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.46Columnlm1000slabelTecCurrentread-onlyoptionalThe value of this object provides the label of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.47Columnlm1000suomTecCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the TEC Current Analog parameter. The unit of measure for this parameter is mA
1.3.6.1.4.1.1166.6.1.2.31.2.1.48Columnlm1000smajorHighTecCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.49Columnlm1000smajorLowTecCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.50Columnlm1000sminorHighTecCurrentread-onlyobsoleteThe value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns inv…
1.3.6.1.4.1.1166.6.1.2.31.2.1.51Columnlm1000sminorLowTecCurrentread-onlyobsoleteThe value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns inva…
1.3.6.1.4.1.1166.6.1.2.31.2.1.52Columnlm1000scurrentValueTecCurrentread-onlymandatoryThe value of this object provides the Current value of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.53Columnlm1000sstateFlagTecCurrentread-onlymandatoryThe value of this object provides the state of the TEC Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.2.1.54Columnlm1000sminValueTecCurrentread-onlymandatoryThe value of this object provides the minimum value the TEC Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.55Columnlm1000smaxValueTecCurrentread-onlymandatoryThe value of this object provides the maximum value the TEC Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.56Columnlm1000salarmStateTecCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the TEC Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.57Columnlm1000slabelModTempread-onlyoptionalThe value of this object provides the label of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.58Columnlm1000suomModTempread-onlyoptionalThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is degrees C
1.3.6.1.4.1.1166.6.1.2.31.2.1.59Columnlm1000smajorHighModTempread-onlymandatoryThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.60Columnlm1000smajorLowModTempread-onlymandatoryThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.61Columnlm1000sminorHighModTempread-onlymandatoryThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.62Columnlm1000sminorLowModTempread-onlymandatoryThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.63Columnlm1000scurrentValueModTempread-onlymandatoryThe value of this object provides the Current value of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.64Columnlm1000sstateFlagModTempread-onlymandatoryThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.2.1.65Columnlm1000sminValueModTempread-onlymandatoryThe value of this object provides the minimum value the Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.66Columnlm1000smaxValueModTempread-onlymandatoryThe value of this object provides the maximum value the Module Temperature Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.67Columnlm1000salarmStateModTempread-onlymandatoryThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.68Columnlm1000slabelFanCurrentread-onlyoptionalThe value of this object provides the label of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.69Columnlm1000suomFanCurrentread-onlyoptionalThe value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA
1.3.6.1.4.1.1166.6.1.2.31.2.1.70Columnlm1000smajorHighFanCurrentread-onlymandatoryThe value of this object provides the Major High alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.71Columnlm1000smajorLowFanCurrentread-onlymandatoryThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.72Columnlm1000sminorHighFanCurrentread-onlyobsoleteThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inv…
1.3.6.1.4.1.1166.6.1.2.31.2.1.73Columnlm1000sminorLowFanCurrentread-onlyobsoleteThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inva…
1.3.6.1.4.1.1166.6.1.2.31.2.1.74Columnlm1000scurrentValueFanCurrentread-onlymandatoryThe value of this object provides the Current value of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.2.1.75Columnlm1000sstateFlagFanCurrentread-onlymandatoryThe value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.2.1.76Columnlm1000sminValueFanCurrentread-onlymandatoryThe value of this object provides the minimum value the Fan Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.77Columnlm1000smaxValueFanCurrentread-onlymandatoryThe value of this object provides the maximum value the Fan Current Analog parameter can achive.
1.3.6.1.4.1.1166.6.1.2.31.2.1.78Columnlm1000salarmStateFanCurrentread-onlymandatoryThe value of this object provides the curent alarm state of the Fan Current Analog parameter.
1.3.6.1.4.1.1166.6.1.2.31.3Tablegx2Lm1000sDigitalTablenot-accessiblemandatoryThis table contains gx2Lm1000sm specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.31.3NodetrapLM1000SfanCurrentAlarmThis trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.31.3.2Rowgx2Lm1000sDigitalEntrynot-accessiblemandatoryThis list contains digital parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.31.3.2.1Columngx2Lm1000sDigitalTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.31.3.2.2Columnlm1000slabelRfInputread-onlyoptionalThe value of this object provides the label of the RF Input Control Digital parameter.
1.3.6.1.4.1.1166.6.1.2.31.3.2.3Columnlm1000senumRfInputread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.31.3.2.4Columnlm1000svalueRfInputread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.31.3.2.5Columnlm1000sstateflagRfInputread-onlymandatoryThe value of this object provides the state of the RF Input Control Digital parameter. (1-hidden 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.3.2.6Columnlm1000slabelOptOutputread-onlyoptionalThe value of this object provides the label of the Optical Output Control Digital parameter.
1.3.6.1.4.1.1166.6.1.2.31.3.2.7Columnlm1000senumOptOutputread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.31.3.2.8Columnlm1000svalueOptOutputread-writemandatoryThe value of this object is the current value of the parameter.
1.3.6.1.4.1.1166.6.1.2.31.3.2.9Columnlm1000sstateflagOptOutputread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.3.2.10Columnlm1000slabelAttnSettingread-onlyoptionalThe value of this object provides the label of the Attenuation Setting Digital parameter.
1.3.6.1.4.1.1166.6.1.2.31.3.2.11Columnlm1000senumAttnSettingread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.31.3.2.12Columnlm1000svalueAttnSettingread-writemandatoryThe value of this object is the current value of the parameter. Each step indicates a .5dB change in attenuation Its range is 0 to 15 dB
1.3.6.1.4.1.1166.6.1.2.31.3.2.13Columnlm1000sstateflagAttnSettingread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.3.2.14Columnlm1000slabelFactoryDefaultread-onlyoptionalThe value of this object provides the label of the Factory Default Digital parameter.
1.3.6.1.4.1.1166.6.1.2.31.3.2.15Columnlm1000senumFactoryDefaultread-onlyoptionalThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value…
1.3.6.1.4.1.1166.6.1.2.31.3.2.16Columnlm1000svalueFactoryDefaultread-writemandatoryThe value of this object is the current value of the parameter. Return value is meaningless
1.3.6.1.4.1.1166.6.1.2.31.3.2.17Columnlm1000sstateflagFactoryDefaultread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.4Tablegx2Lm1000sStatusTablenot-accessiblemandatoryThis table contains gx2Lm1000s specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.31.4NodetrapLM1000SModuleTempAlarmThis trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.31.4.3Rowgx2Lm1000sStatusEntrynot-accessiblemandatoryThis list contains Status parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.31.4.3.1Columngx2Lm1000sStatusTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.31.4.3.2Columnlm1000slabelBootread-onlyoptionalThe value of this object provides the label of the Boot Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.31.4.3.3Columnlm1000svalueBootread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.31.4.3.4Columnlm1000sstateflagBootread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.4.3.5Columnlm1000slabelFlashread-onlyoptionalThe value of this object provides the label of the Flash Status Status parameter.
1.3.6.1.4.1.1166.6.1.2.31.4.3.6Columnlm1000svalueFlashread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.31.4.3.7Columnlm1000sstateflagFlashread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.4.3.8Columnlm1000slabelFactoryDataCRCread-onlyoptionalThe value of this object provides the label of the Factory Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.31.4.3.9Columnlm1000svalueFactoryDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.31.4.3.10Columnlm1000sstateflagFactoryDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.4.3.11Columnlm1000slabelLaserDataCRCread-onlyoptionalThe value of this object provides the label of the Laser Data CRC Status parameter.
1.3.6.1.4.1.1166.6.1.2.31.4.3.12Columnlm1000svalueLaserDataCRCread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.31.4.3.13Columnlm1000sstateflagLaserDataCRCread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.4.3.14Columnlm1000slabelAlarmDataCrcread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.31.4.3.15Columnlm1000svalueAlarmDataCrcread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.31.4.3.16Columnlm1000sstateflagAlarmDataCrcread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.4.3.17Columnlm1000slabelRFInputStatusread-onlyoptionalThe value of this object provides the label of the Alarm Data Crc parameter.
1.3.6.1.4.1.1166.6.1.2.31.4.3.18Columnlm1000svalueRFInputStatusread-onlymandatoryThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
1.3.6.1.4.1.1166.6.1.2.31.4.3.19Columnlm1000sstateflagRFInputStatusread-onlymandatoryThe value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable).
1.3.6.1.4.1.1166.6.1.2.31.5Tablegx2Lm1000sFactoryTablenot-accessiblemandatoryThis table contains gx2Lm1000s specific parameters with nominal and current values.
1.3.6.1.4.1.1166.6.1.2.31.5NodetrapLM1000SomiOffsetAlarmThis trap is issued when the OMI Offset goes out of range.
1.3.6.1.4.1.1166.6.1.2.31.5.4Rowgx2Lm1000sFactoryEntrynot-accessiblemandatoryThis list contains Factory parameters and descriptions.
1.3.6.1.4.1.1166.6.1.2.31.5.4.1Columngx2Lm1000sFactoryTableIndexread-onlymandatoryThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
1.3.6.1.4.1.1166.6.1.2.31.5.4.2Columnlm1000sbootControlByteread-onlymandatoryThe value of this object indicates which bank the firmware is currently being boot from.
1.3.6.1.4.1.1166.6.1.2.31.5.4.3Columnlm1000sbootStatusByteread-onlymandatoryThis object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 =…
1.3.6.1.4.1.1166.6.1.2.31.5.4.4Columnlm1000sbank1CRCread-onlymandatoryThis object provides the CRC code of bank 0. The display formate for the data is Hex.
1.3.6.1.4.1.1166.6.1.2.31.5.4.5Columnlm1000sbank2CRCread-onlymandatoryThis object provides the CRC code of bank 1.The display formate for the data is Hex.
1.3.6.1.4.1.1166.6.1.2.31.5.4.6Columnlm1000sprgEEPROMByteread-onlymandatoryThis object indicates if the EEPROM has been programmed
1.3.6.1.4.1.1166.6.1.2.31.5.4.7Columnlm1000sfactoryCRCread-onlymandatoryThis object provides the CRC code for the Factory data.
1.3.6.1.4.1.1166.6.1.2.31.5.4.8Columnlm1000scalculateCRCread-onlyobsoleteThis object indicates which of the Enums will have the CRC calculated.
1.3.6.1.4.1.1166.6.1.2.31.5.4.9Columnlm1000shourMeterread-onlymandatoryThis object provides the hour meter reading of the module.
1.3.6.1.4.1.1166.6.1.2.31.5.4.10Columnlm1000sflashPrgCntAread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.31.5.4.11Columnlm1000sflashPrgCntBread-onlymandatoryThis object provides the number of times Bank 1 flash has been programmed.
1.3.6.1.4.1.1166.6.1.2.31.5.4.12Columnlm1000sflashBankARevread-onlymandatoryThis object provides the revision of flash bank 0. The rev is 2 characters.
1.3.6.1.4.1.1166.6.1.2.31.5.4.13Columnlm1000sflashBankBRevread-onlymandatoryThis object provides the revision of flash bank 1. The rev is 2 characters.
1.3.6.1.4.1.1166.6.1.2.31.6NodetrapLM1000StecCurrentAlarmThis trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.31.7NodetrapLM1000SLaserCurrentAlarmThis trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.31.8NodetrapLM1000SLaserTempAlarmThis trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.31.9NodetrapLM1000SLaserPowerAlarmThis trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
1.3.6.1.4.1.1166.6.1.2.31.10NodetrapLM1000SFlashAlarmThis trap is issued when the Laser Modules detects an error during Flash memory operations.
1.3.6.1.4.1.1166.6.1.2.31.11NodetrapLM1000SBankBootAlarmThis trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
1.3.6.1.4.1.1166.6.1.2.31.12NodetrapLM1000SAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.31.13NodetrapLM1000SFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.31.14NodetrapLM1000SCalDataCRCAlarmThis trap is issued when the Cal Data CRC is incorrect.
1.3.6.1.4.1.1166.6.1.2.31.15NodetrapLM1000SResetFacDefaultThis trap is issued when the LM1000S resets to factory defaults
1.3.6.1.4.1.1166.6.1.2.31.16NodetrapLM1000SUserRFOffAlarmThis trap is issued when the the User RF is turned off.
1.3.6.1.4.1.1166.6.1.2.31.17NodetrapLM1000SUserOpticalOffAlarmThis trap is issued when the User Optical Power is turned off.
1.3.6.1.4.1.1166.6.1.2.31.18NodetrapLM1000SUserSBSOffAlarmThis trap is issued when the User SBS is turned off.
1.3.6.1.4.1.1166.6.1.2.31.19NodetrapLM1000SRFInputAlarmThis trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame…
1.3.6.1.4.1.1166.6.1.2.31.20NodetrapLM1000SRFOverloadAlarmThis trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par…