OMNI-gx2Lm1000s-MIB
156 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.31.1 | Nodegx2Lm1000sDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.31.1 | NodetrapLM1000SConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.31.2 | Tablegx2Lm1000sAnalogTable | not-accessible | mandatory | This table contains gx2Lm1000s specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.31.2 | NodetrapLM1000SConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.31.2.1 | Rowgx2Lm1000sAnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.1 | Columngx2Lm1000sAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.2 | Columnlm1000slabelOffsetNomMonitor | read-only | optional | The value of this object provides the label of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.3 | Columnlm1000suomOffsetNomMonitor | read-only | optional | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. The unit of measure for this parameter is dB |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.4 | Columnlm1000smajorHighOffsetNomMonitor | read-only | obsolete | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This object is not used by this module and always returns … |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.5 | Columnlm1000smajorLowOffsetNomMonitor | read-only | obsolete | The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always ret… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.6 | Columnlm1000sminorHighOffsetNomMonitor | read-only | obsolete | The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always re… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.7 | Columnlm1000sminorLowOffsetNomMonitor | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always ret… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.8 | Columnlm1000scurrentValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the Current value of the Offset Monitor Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.9 | Columnlm1000sstateFlagOffsetNomMonitor | read-only | mandatory | The value of this object provides the state of the Offset Monitor Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.10 | Columnlm1000sminValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.11 | Columnlm1000smaxValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.12 | Columnlm1000salarmStateOffsetNomMonitor | read-only | mandatory | The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.13 | Columnlm1000slabelLaserPower | read-only | optional | The value of this object provides the label of the Laser Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.14 | Columnlm1000suomLaserPower | read-only | optional | The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter. The unit of measure for this parameter is dBm |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.15 | Columnlm1000smajorHighLaserPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.16 | Columnlm1000smajorLowLaserPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.17 | Columnlm1000sminorHighLaserPower | read-only | obsolete | The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always ret… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.18 | Columnlm1000sminorLowLaserPower | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always retu… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.19 | Columnlm1000scurrentValueLaserPower | read-only | mandatory | The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.20 | Columnlm1000sstateFlagLaserPower | read-only | mandatory | The value of this object provides the state of the Laser Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.21 | Columnlm1000sminValueLaserPower | read-only | mandatory | The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.22 | Columnlm1000smaxValueLaserPower | read-only | mandatory | The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.23 | Columnlm1000salarmStateLaserPower | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.24 | Columnlm1000slabelLaserTemp | read-only | optional | The value of this object provides the label of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.25 | Columnlm1000suomLaserTemp | read-only | optional | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. The unit of measure for this parameter is degrees C |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.26 | Columnlm1000smajorHighLaserTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.27 | Columnlm1000smajorLowLaserTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.28 | Columnlm1000sminorHighLaserTemp | read-only | obsolete | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.29 | Columnlm1000sminorLowLaserTemp | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.30 | Columnlm1000scurrentValueLaserTemp | read-only | mandatory | The value of this object provides the Current value of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.31 | Columnlm1000sstateFlagLaserTemp | read-only | mandatory | The value of this object provides the state of the Laser Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.32 | Columnlm1000sminValueLaserTemp | read-only | mandatory | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.33 | Columnlm1000smaxValueLaserTemp | read-only | mandatory | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.34 | Columnlm1000salarmStateLaserTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.35 | Columnlm1000slabelLaserCurrent | read-only | optional | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.36 | Columnlm1000suomLaserCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter. The unit of measure for this parameter is mA |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.37 | Columnlm1000smajorHighLaserCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.38 | Columnlm1000smajorLowLaserCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.39 | Columnlm1000sminorHighLaserCurrent | read-only | obsolete | The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always retu… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.40 | Columnlm1000sminorLowLaserCurrent | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always retur… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.41 | Columnlm1000scurrentValueLaserCurrent | read-only | mandatory | The value of this object provides the Current value of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.42 | Columnlm1000sstateFlagLaserCurrent | read-only | mandatory | The value of this object provides the state of the Laser Bias Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.43 | Columnlm1000sminValueLaserCurrent | read-only | mandatory | The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.44 | Columnlm1000smaxValueLaserCurrent | read-only | mandatory | The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.45 | Columnlm1000salarmStateLaserCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.46 | Columnlm1000slabelTecCurrent | read-only | optional | The value of this object provides the label of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.47 | Columnlm1000suomTecCurrent | read-only | optional | The value of this object provides the Unit of Measure of the TEC Current Analog parameter. The unit of measure for this parameter is mA |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.48 | Columnlm1000smajorHighTecCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.49 | Columnlm1000smajorLowTecCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.50 | Columnlm1000sminorHighTecCurrent | read-only | obsolete | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns inv… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.51 | Columnlm1000sminorLowTecCurrent | read-only | obsolete | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns inva… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.52 | Columnlm1000scurrentValueTecCurrent | read-only | mandatory | The value of this object provides the Current value of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.53 | Columnlm1000sstateFlagTecCurrent | read-only | mandatory | The value of this object provides the state of the TEC Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.54 | Columnlm1000sminValueTecCurrent | read-only | mandatory | The value of this object provides the minimum value the TEC Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.55 | Columnlm1000smaxValueTecCurrent | read-only | mandatory | The value of this object provides the maximum value the TEC Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.56 | Columnlm1000salarmStateTecCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.57 | Columnlm1000slabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.58 | Columnlm1000suomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is degrees C |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.59 | Columnlm1000smajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.60 | Columnlm1000smajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.61 | Columnlm1000sminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.62 | Columnlm1000sminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.63 | Columnlm1000scurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.64 | Columnlm1000sstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.65 | Columnlm1000sminValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.66 | Columnlm1000smaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.67 | Columnlm1000salarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.68 | Columnlm1000slabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.69 | Columnlm1000suomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.70 | Columnlm1000smajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.71 | Columnlm1000smajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.72 | Columnlm1000sminorHighFanCurrent | read-only | obsolete | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inv… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.73 | Columnlm1000sminorLowFanCurrent | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns inva… |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.74 | Columnlm1000scurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.75 | Columnlm1000sstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.76 | Columnlm1000sminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.77 | Columnlm1000smaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.31.2.1.78 | Columnlm1000salarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.3 | Tablegx2Lm1000sDigitalTable | not-accessible | mandatory | This table contains gx2Lm1000sm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.31.3 | NodetrapLM1000SfanCurrentAlarm | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.3.2 | Rowgx2Lm1000sDigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.1 | Columngx2Lm1000sDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.2 | Columnlm1000slabelRfInput | read-only | optional | The value of this object provides the label of the RF Input Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.3 | Columnlm1000senumRfInput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.4 | Columnlm1000svalueRfInput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.5 | Columnlm1000sstateflagRfInput | read-only | mandatory | The value of this object provides the state of the RF Input Control Digital parameter. (1-hidden 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.6 | Columnlm1000slabelOptOutput | read-only | optional | The value of this object provides the label of the Optical Output Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.7 | Columnlm1000senumOptOutput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.8 | Columnlm1000svalueOptOutput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.9 | Columnlm1000sstateflagOptOutput | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.10 | Columnlm1000slabelAttnSetting | read-only | optional | The value of this object provides the label of the Attenuation Setting Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.11 | Columnlm1000senumAttnSetting | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.12 | Columnlm1000svalueAttnSetting | read-write | mandatory | The value of this object is the current value of the parameter. Each step indicates a .5dB change in attenuation Its range is 0 to 15 dB |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.13 | Columnlm1000sstateflagAttnSetting | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.14 | Columnlm1000slabelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.15 | Columnlm1000senumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.16 | Columnlm1000svalueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. Return value is meaningless |
| 1.3.6.1.4.1.1166.6.1.2.31.3.2.17 | Columnlm1000sstateflagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.4 | Tablegx2Lm1000sStatusTable | not-accessible | mandatory | This table contains gx2Lm1000s specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.31.4 | NodetrapLM1000SModuleTempAlarm | This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.4.3 | Rowgx2Lm1000sStatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.1 | Columngx2Lm1000sStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.2 | Columnlm1000slabelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.3 | Columnlm1000svalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.4 | Columnlm1000sstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.5 | Columnlm1000slabelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.6 | Columnlm1000svalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.7 | Columnlm1000sstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.8 | Columnlm1000slabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.9 | Columnlm1000svalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.10 | Columnlm1000sstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.11 | Columnlm1000slabelLaserDataCRC | read-only | optional | The value of this object provides the label of the Laser Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.12 | Columnlm1000svalueLaserDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.13 | Columnlm1000sstateflagLaserDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.14 | Columnlm1000slabelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.15 | Columnlm1000svalueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.16 | Columnlm1000sstateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.17 | Columnlm1000slabelRFInputStatus | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.18 | Columnlm1000svalueRFInputStatus | read-only | mandatory | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| 1.3.6.1.4.1.1166.6.1.2.31.4.3.19 | Columnlm1000sstateflagRFInputStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| 1.3.6.1.4.1.1166.6.1.2.31.5 | Tablegx2Lm1000sFactoryTable | not-accessible | mandatory | This table contains gx2Lm1000s specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.31.5 | NodetrapLM1000SomiOffsetAlarm | This trap is issued when the OMI Offset goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.5.4 | Rowgx2Lm1000sFactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.1 | Columngx2Lm1000sFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.2 | Columnlm1000sbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.3 | Columnlm1000sbootStatusByte | read-only | mandatory | This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 =… |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.4 | Columnlm1000sbank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. The display formate for the data is Hex. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.5 | Columnlm1000sbank2CRC | read-only | mandatory | This object provides the CRC code of bank 1.The display formate for the data is Hex. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.6 | Columnlm1000sprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.7 | Columnlm1000sfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.8 | Columnlm1000scalculateCRC | read-only | obsolete | This object indicates which of the Enums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.9 | Columnlm1000shourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.10 | Columnlm1000sflashPrgCntA | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.11 | Columnlm1000sflashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.12 | Columnlm1000sflashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. The rev is 2 characters. |
| 1.3.6.1.4.1.1166.6.1.2.31.5.4.13 | Columnlm1000sflashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. The rev is 2 characters. |
| 1.3.6.1.4.1.1166.6.1.2.31.6 | NodetrapLM1000StecCurrentAlarm | This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.7 | NodetrapLM1000SLaserCurrentAlarm | This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.8 | NodetrapLM1000SLaserTempAlarm | This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.9 | NodetrapLM1000SLaserPowerAlarm | This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.10 | NodetrapLM1000SFlashAlarm | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.11 | NodetrapLM1000SBankBootAlarm | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.12 | NodetrapLM1000SAlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.13 | NodetrapLM1000SFactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.14 | NodetrapLM1000SCalDataCRCAlarm | This trap is issued when the Cal Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.15 | NodetrapLM1000SResetFacDefault | This trap is issued when the LM1000S resets to factory defaults | ||
| 1.3.6.1.4.1.1166.6.1.2.31.16 | NodetrapLM1000SUserRFOffAlarm | This trap is issued when the the User RF is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.17 | NodetrapLM1000SUserOpticalOffAlarm | This trap is issued when the User Optical Power is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.18 | NodetrapLM1000SUserSBSOffAlarm | This trap is issued when the User SBS is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.31.19 | NodetrapLM1000SRFInputAlarm | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame… | ||
| 1.3.6.1.4.1.1166.6.1.2.31.20 | NodetrapLM1000SRFOverloadAlarm | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… |