OMNI-gx2Lm870C-MIB
171 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.10.1 | Nodegx2Lm870CDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.10.1 | NodetrapLM870CConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.10.2 | Tablegx2lm870CAnalogTable | not-accessible | mandatory | This table contains gx2Lm870C specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.10.2 | NodetrapLMCConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.10.2.1 | Rowgx2lm870CAnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.1 | Columngx2Lm870CAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.2 | Columnlm870ClabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.3 | Columnlm870CuomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.4 | Columnlm870CmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.5 | Columnlm870CmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.6 | Columnlm870CminorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.7 | Columnlm870CminorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.8 | Columnlm870CcurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.9 | Columnlm870CstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.10 | Columnlm870CminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.11 | Columnlm870CmaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.12 | Columnlm870CalarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.13 | Columnlm870Clabel12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.14 | Columnlm870Cuom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.15 | Columnlm870CmajorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.16 | Columnlm870CmajorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.17 | Columnlm870CminorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.18 | Columnlm870CminorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.19 | Columnlm870CcurrentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.20 | Columnlm870CstateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.21 | Columnlm870CminValue12Volt | read-only | mandatory | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.22 | Columnlm870CmaxValue12Volt | read-only | mandatory | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.23 | Columnlm870CalarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.24 | Columnlm870ClabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.25 | Columnlm870CuomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.26 | Columnlm870CmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.27 | Columnlm870CmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.28 | Columnlm870CminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.29 | Columnlm870CminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.30 | Columnlm870CcurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.31 | Columnlm870CstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.32 | Columnlm870CminValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.33 | Columnlm870CmaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.34 | Columnlm870CalarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.35 | Columnlm870ClabelOmiOffset | read-only | optional | The value of this object provides the label of the OMI Offset Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.36 | Columnlm870CuomOmiOffset | read-only | optional | The value of this object provides the Unit of Measure of the OMI Offset Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.37 | Columnlm870CmajorHighOmiOffset | read-only | mandatory | The value of this object provides the Major High alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.38 | Columnlm870CmajorLowOmiOffset | read-only | mandatory | The value of this object provides the Major Low alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.39 | Columnlm870CminorHighOmiOffset | read-only | mandatory | The value of this object provides the Minor High alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.40 | Columnlm870CminorLowOmiOffset | read-only | mandatory | The value of this object provides the Minor Low alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.41 | Columnlm870CcurrentValueOmiOffset | read-only | mandatory | The value of this object provides the Current value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.42 | Columnlm870CstateFlagOmiOffset | read-only | mandatory | The value of this object provides the state of the OMI Offset Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.43 | Columnlm870CminValueOmiOffset | read-only | mandatory | The value of this object provides the minimum value the OMI Offset Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.44 | Columnlm870CmaxValueOmiOffset | read-only | mandatory | The value of this object provides the maximum value the OMI Offset Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.45 | Columnlm870CalarmStateOmiOffset | read-only | mandatory | The value of this object provides the curent alarm state of the OMI Offset Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.46 | Columnlm870ClabelOPTPower | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.47 | Columnlm870CuomOPTPower | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter.. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.48 | Columnlm870CmajorHighOPTPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.49 | Columnlm870CmajorLowOPTPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.50 | Columnlm870CminorHighOPTPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.51 | Columnlm870CminorLowOPTPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.52 | Columnlm870CcurrentValueOPTPower | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.53 | Columnlm870CstateFlagOPTPower | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.54 | Columnlm870CminValueOPTPower | read-only | mandatory | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.55 | Columnlm870CmaxValueOPTPower | read-only | mandatory | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.56 | Columnlm870CalarmStateOPTPower | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.57 | Columnlm870ClabelLaserBias | read-only | optional | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.58 | Columnlm870CuomLaserBias | read-only | optional | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.59 | Columnlm870CmajorHighLaserBias | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.60 | Columnlm870CmajorLowLaserBias | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.61 | Columnlm870CminorHighLaserBias | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.62 | Columnlm870CminorLowLaserBias | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.63 | Columnlm870CcurrentValueLaserBias | read-only | mandatory | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.64 | Columnlm870CstateFlagLaserBias | read-only | mandatory | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.65 | Columnlm870CminValueLaserBias | read-only | mandatory | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.66 | Columnlm870CmaxValueLaserBias | read-only | mandatory | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.67 | Columnlm870CalarmStateLaserBias | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.68 | Columnlm870ClabelTecCurrent | read-only | optional | The value of this object provides the label of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.69 | Columnlm870CuomTecCurrent | read-only | optional | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.70 | Columnlm870CmajorHighTecCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.71 | Columnlm870CmajorLowTecCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.72 | Columnlm870CminorHighTecCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.73 | Columnlm870CminorLowTecCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.74 | Columnlm870CcurrentValueTecCurrent | read-only | mandatory | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.75 | Columnlm870CstateFlagTecCurrent | read-only | mandatory | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.76 | Columnlm870CminValueTecCurrent | read-only | mandatory | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.77 | Columnlm870CmaxValueTecCurrent | read-only | mandatory | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.78 | Columnlm870CalarmStateTecCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.79 | Columnlm870ClabelOmiAlarmSetpoint | read-only | optional | The value of this object provides the label of the OMI Offset Alarm Setpoint Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.80 | Columnlm870CuomOmiAlarmSetpoint | read-only | optional | The value of this object provides the Unit of Measure of the OMI Offset Alarm Setpoint Analog parameter.. |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.81 | Columnlm870CmajorHighOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the Major High alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is r… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.82 | Columnlm870CmajorLowOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the Major Low alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.83 | Columnlm870CminorHighOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the Minor High alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is r… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.84 | Columnlm870CminorLowOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the Minor Low alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.85 | Columnlm870CcurrentValueOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the Current value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.86 | Columnlm870CstateFlagOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the state of the OMI Offset Alarm Setpoint Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.87 | Columnlm870CminValueOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the minimum value the OMI Offset Alarm Setpoint Analog parameter can achive. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.88 | Columnlm870CmaxValueOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the maximum value the OMI Offset Alarm Setpoint Analog parameter can achive. This value is a floating point number that is re… |
| 1.3.6.1.4.1.1166.6.1.2.10.2.1.89 | Columnlm870CalarmStateOmiAlarmSetpoint | read-only | mandatory | The value of this object provides the curent alarm state of the OMI Offset Alarm Setpoint Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.3 | Tablegx2lm870CDigitalTable | not-accessible | mandatory | This table contains gx2Lm870C specific parameters with discrete values. |
| 1.3.6.1.4.1.1166.6.1.2.10.3 | NodetrapLMCFanCurrentAlarm | This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.10.3.2 | Rowgx2lm870CDigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.1 | Columngx2Lm870CDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.2 | Columnlm870ClabelOMIOffsetAlarms | read-only | optional | The value of this object provides the label of the OMI Offset Alarm mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.3 | Columnlm870CenumOMIOffsetAlarms | read-only | optional | The value of this object represents the Enumeration values possible for the OMI Offset Alarm modeDigital parameter. Each Enumerated values is separated by a co… |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.4 | Columnlm870CvalueOMIOffsetAlarms | read-write | mandatory | The value of this object is the current value of the parameter. Note that the value to be read will always be 1 or 2 because the set value (3) is always change… |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.5 | Columnlm870CstateFlagOMIOffsetAlarms | read-only | mandatory | The value of this object provides the state of the OMI Offset Alarm mode Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.6 | Columnlm870ClabelFactoryDefault | read-only | optional | The value of this object provides the label of the Reset to Factory Default Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.7 | Columnlm870CenumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Reste to Factory Default Digital parameter. Each Enumerated values is separated by … |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.8 | Columnlm870CvalueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.9 | Columnlm870CstateFlagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.10 | Columnlm870ClabelOMISetpoint | read-only | obsolete | The value of this object provides the label of the OMI Setpoint Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.11 | Columnlm870CenumOMISetpoint | read-only | obsolete | The value of this object represents the Enumeration values possible for the OMI Setpoint Digital parameter. Each Enumerated values is separated by a common. Th… |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.12 | Columnlm870CvalueOMISetpoint | read-only | obsolete | The value of this object is the current value of the OMI Setpoint parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.3.2.13 | Columnlm870CstateFlagOMISetpoint | read-only | obsolete | The value of this object provides the state of the OMI Setpoint Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4 | Tablegx2lm870CStatusTable | not-accessible | mandatory | This table contains gx2Lm870C specific parameters with current values. |
| 1.3.6.1.4.1.1166.6.1.2.10.4 | NodetrapLMC12vAlarm | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this paramet… | ||
| 1.3.6.1.4.1.1166.6.1.2.10.4.3 | Rowgx2lm870CStatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.1 | Columngx2Lm870CStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.2 | Columnlm870ClabelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.3 | Columnlm870CvalueBoot | read-only | mandatory | The value of this object provides the current value of the boot status parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.4 | Columnlm870CstateflagBoot | read-only | mandatory | The value of this object provides the state of the the boot status parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.5 | Columnlm870ClabelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.6 | Columnlm870CvalueFlash | read-only | mandatory | The value of this object provides the current value of the Flash Status parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.7 | Columnlm870CstateflagFlash | read-only | mandatory | The value of this object provides the state current of the the Flash Status parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.8 | Columnlm870ClabelRFOverload | read-only | optional | The value of this object provides the label for the RF Overload Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.9 | Columnlm870CvalueRFOverload | read-only | mandatory | The value of this object provides the current value of the RF Overload parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.10 | Columnlm870CstateflagRFOverload | read-only | mandatory | The value of this object provides the current state of the RF Overload parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.11 | Columnlm870ClabelRFPower | read-only | optional | The value of this object provides the label for the RF Power Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.12 | Columnlm870CvalueRFPower | read-only | mandatory | The value of this object provides the current value of the RF Power parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.13 | Columnlm870CstateflagRFPower | read-only | mandatory | The value of this object provides the current state of the RF Power parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.14 | Columnlm870ClabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.15 | Columnlm870CvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current value of the Factory Data CRC parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.16 | Columnlm870CstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the the Factory Data CRC parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.17 | Columnlm870ClabelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.18 | Columnlm870CvalueAlarmDataCrc | read-only | mandatory | The value of this object provides the current value of the Alarm Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.19 | Columnlm870CstateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the the Alarm Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.20 | Columnlm870ClabelModSetDataCRC | read-only | optional | The value of this object provides the label of the Module Settings Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.21 | Columnlm870CvalueModSetDataCRC | read-only | mandatory | The value of this object provides the current value of the Module Settings Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.22 | Columnlm870CstateflagModSetDataCRC | read-only | mandatory | The value of this object provides the current state of the the Module Settings Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.23 | Columnlm870ClabelOptCalDataCRC | read-only | optional | The value of this object provides the label of the Optical Calibration Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.24 | Columnlm870CvalueOptCalDataCRC | read-only | mandatory | The value of this object provides the current value of the Optical Calibration Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical… |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.25 | Columnlm870CstateflagOptCalDataCRC | read-only | mandatory | The value of this object provides the current state of the the Optical Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.26 | Columnlm870ClabelRFCalDataCRC | read-only | optional | The value of this object provides the label of the RF Calibration Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.27 | Columnlm870CvalueRFCalDataCRC | read-only | mandatory | The value of this object provides the current value of the RF Calibration Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.10.4.3.28 | Columnlm870CstateflagRFCalDataCRC | read-only | mandatory | The value of this object provides the current state of the the RF Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.10.5 | Tablegx2lm870CFactoryTable | not-accessible | mandatory | This table contains gx2Lm870C specific parameters with stored factory values. |
| 1.3.6.1.4.1.1166.6.1.2.10.5 | NodetrapLMCModuleTempAlarm | This trap is issued when the Laser Module Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.5.4 | Rowgx2lm870CFactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.1 | Columngx2Lm870CFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.2 | Columnlm870CbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.3 | Columnlm870CbootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.4 | Columnlm870Cbank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.5 | Columnlm870Cbank2CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.6 | Columnlm870CprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.7 | Columnlm870CfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.8 | Columnlm870CcalculateCRC | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.9 | Columnlm870ChourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.10 | Columnlm870CflashPrgCntA | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.11 | Columnlm870CflashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.12 | Columnlm870CflashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.10.5.4.13 | Columnlm870CflashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.10.6 | NodetrapLMCRFPowerAlarm | This trap is issued when the Laser Modules RF Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame… | ||
| 1.3.6.1.4.1.1166.6.1.2.10.7 | NodetrapLMCOPTPowerAlarm | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this p… | ||
| 1.3.6.1.4.1.1166.6.1.2.10.8 | NodetrapLMCLaserBiasAlarm | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.9 | NodetrapLMCTECCurrentAlarm | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.10.10 | NodetrapLMCFlashAlarm | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.11 | NodetrapLMCBankBootAlarm | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.12 | NodetrapLMCAlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.13 | NodetrapLMCModSetDataCRCAlarm | This trap is issued when the Module Settings CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.14 | NodetrapLMCFactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.15 | NodetrapLMCResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.16 | NodetrapLMCOPCalDataCRCAlarm | This trap is issued when the Optical Calibration Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.17 | NodetrapLMCRFCalDataCRCAlarm | This trap is issued when the RF Calibration Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.18 | NodetrapLMCRFOverloadAlarm | This trap is issued when the RF Overload alarm occurs. | ||
| 1.3.6.1.4.1.1166.6.1.2.10.19 | NodetrapLMCOMIoffsetAlarm | This trap is issued when an OMI Offset alarm occurs. |